i950
Servo drives i950 are designed for a power range of 22 - 110 kW, extending the i750 series within the Lenze automation system. Integration into modular machine applications is achieved through ready-made technology applications (parameterization instead of programming).
The architecture is unified for both centralized and decentralized motion control, enabling reuse of the same application software across different system configurations. Software modules are modular and expandable.
Key features
- Prepared technology applications: table positioning, electronic gearbox, winder
- One Cable Technology (OCT)
- Modular scalability of feedback system and bus connection
- Auto-tuning function for fast and easy controller setup
- Integrated safety technology up to SIL 3 / PL e Cat. 4
- Compliance with Ecodesign directive requirements, standard EN IEC 61800-9-2
- Rated power 0.37 kW/0.5 HP
- Output current 2.4 A
- Output frequency 0-599 Hz
- Rated mains voltage 1/N(3)/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 0.55 kW/0.75 HP
- Output current 3.2 A
- Output frequency 0-599 Hz
- Rated mains voltage 1/N(3)/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 0.55 kW/0.75 HP
- Output current 1.8/1.6 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 0.75 kW/1 HP
- Output current 4.2 A
- Output frequency 0-599 Hz
- Rated mains voltage 1/N(3)/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 0.75 kW/1 HP
- Output current 2.4/2.1 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 1.5 kW/2 HP
- Output current 7 A
- Output frequency 0-599 Hz
- Rated mains voltage 1/N(3)/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 2.2 kW/3 HP
- Output current 9.6 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 2.2 kW/3 HP
- Output current 5.6/4.8 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 4 kW/5 HP
- Output current 16.5 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 4 kW/5 HP
- Output current 9.5/8.2 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 5.5 kW/7.5 HP
- Output current 23 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 7.5 kW/10 HP
- Output current 16.5/14 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 11 kW/15 HP
- Output current 23.5/21 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 15 kW/20 HP
- Output current 32/27 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 22 kW/30 HP
- Output current 47/40.4 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 30 kW/40 HP
- Output current 61/52 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 45 kW/60 HP
- Output current 89/77 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 55 kW/75 HP
- Output current 110/96 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 75 kW/100 HP
- Output current 150/124 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 90 kW/125 HP
- Output current 180/156 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 110 kW/150 HP
- Output current 212/180 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
| Title | Language | File | Document type |
|---|---|---|---|
| i950 cabinet servo drive (Gen B) | EN | i950 cabinet servo drive (Gen B) - EN.pdf | Project planning |
| i950 cabinet servo drive (Gen B) | DE | Servoumrichter i950 cabinet (Gen B)_DE.pdf | Project planning |
| CE (European Union), Extended Safety | EN, DE | CE_Con__Servo_i950_ES__DE_EN.pdf | Conformity |
| CE (European Union), Basic Safety | EN, DE | CE_Con__Servo_i950_BS__DE_EN.pdf | Conformity |
| i950 cabinet servo drive (Gen A) | EN | i950 cabinet servo drive (Gen A) - EN.pdf | Project planning |
| i950 cabinet servo drive (Gen A) | DE | Servoumrichter i950 cabinet (Gen A)_DE.pdf | Project planning |
| CE (European Union), Extended Safety, Revision List | EN | EC_Type__Servo_i950_ES_RevList__EN.pdf | Functional safety |
| CE (European Union), Extended Safety | EN | EC_Type__Servo_i950_ES__EN.pdf | Functional safety |
| CE (European Union), Basic Safety, Revision List | EN | EC_Type__Servo_i950_BS_RevList__EN.pdf | Functional safety |
| CE (European Union), Basic Safety | EN | EC_Type__Servo_i950_BS__EN.pdf | Functional safety |
| i950 cabinet servo inverter | EN, BG, CS, DE, ES, FR, HR, HU, IT, PL, PT, RU, SK, SL, US, ZH | MOB_Servoumrichter_i950c_web.pdf | Mounting instructions |
| i950 cabinet servo inverter | SK | i950_cabinet_servo_inverter_SK.pdf | Flyer |
| i950 cabinet servo inverter | ZH | i950_cabinet_servo_inverter_ZH.pdf | Flyer |
| i950 cabinet servo inverter | RU | i950_cabinet_servo_inverter_RU.pdf | Flyer |
| i950 cabinet servo inverter | PT | i950_cabinet_servo_inverter_PT.pdf | Flyer |
| i950 cabinet servo inverter | PL | i950_cabinet_servo_inverter_PL.pdf | Flyer |
| i950 cabinet servo inverter | IT | i950_cabinet_servo_inverter_IT.pdf | Flyer |
| i950 cabinet servo inverter | HU | i950_cabinet_servo_inverter_HU.pdf | Flyer |
| i950 cabinet servo inverter | FR | i950_cabinet_servo_inverter_FR.pdf | Flyer |
| i950 cabinet servo inverter | ES | i950_cabinet_servo_inverter_ES.pdf | Flyer |
| i950 cabinet servo inverter | US | i950_cabinet_servo_inverter_US.pdf | Flyer |
| i950 cabinet servo inverter | EN | i950_cabinet_servo_inverter_Flyer_EN.pdf | Flyer |
| i950 cabinet servo inverter | DE | i950_cabinet_servo_inverter_Flyer_DE.pdf | Flyer |
| i950 cabinet servo inverter | CS | i950_cabinet_servo_inverter_CS.pdf | Flyer |
| Cyber Security | EN | Cyber Security_EN.pdf | Manuals |
| UKCA (United Kingdom) | EN | UKCA_2511948-01_LVD_EMC_RoHS_i950_Accessories.pdf | Conformity |
| UKCA (United Kingdom), Extended Safety | EN | UKCA_2458899-03_MD_EMC_ERP_RoHS_i950_ES.pdf | Conformity |
| CE (European Union) | EN, DE | CE_2369291-09_LVD_EMC_RoHS_i950_Accessories.pdf | Conformity |
| UL, DOE (USA) | EN | UL,_DOE_(USA)_i950__EN.pdf | Conformity |
| UKCA (United Kingdom), Basic Safety | EN | UKCA_2458906-02_MD_EMC_ERP_RoHS_i950_BS-STO.pdf | Conformity |
| Table positioning | EN | Table positioning - EN.pdf | Manuals |
| Table positioning | DE | Tabellenpositionierung_DE.pdf | Manuals |
| UKCA (United Kingdom), Basic Safety, Revision List | EN | 01_205(U)_5605_01_22_RL_2022_12_19.pdf | Functional safety |
| UKCA (United Kingdom), Basic Safety | EN | 01_205U_5605_01_22_en_el.pdf | Functional safety |
| UKCA (United Kingdom), Extended Safety, Revision List | EN | UKCA (United Kingdom), Extended Safety, Revision List - EN.pdf | Functional safety |
| UKCA (United Kingdom), Extended Safety | EN | 01_205U_5657_01_23_en_el.pdf | Functional safety |
| "CiA 402 advanced" technology application | EN | CiA 402 advanced technology application - EN.pdf | Commissioning |
| "CiA 402 advanced" technology application | DE | Technologieapplikation "CiA402 advanced"_DE.pdf | Commissioning |
| "Speed Control" technology application | EN | Speed Control technology application - EN.pdf | Commissioning |
| "Speed Control" technology application | DE | Technologieapplikation "Speed Control"_DE.pdf | Commissioning |
| i950 cabinet servo inverter | EN | i950_cabinet_servo_inverter_Commissioning_EN.pdf | Commissioning |
| i950 cabinet servo inverter | DE | i950_cabinet_servo_inverter_Commissioning_DE.pdf | Commissioning |
| "Winder Dancer" technology application | EN | Winder Dancer technology application - EN.pdf | Commissioning |
| "Winder Dancer" technology application | DE | Technologieapplikation "Winder Dancer"_DE.pdf | Commissioning |
| "Electronic Gearbox" technology application | EN | Electronic Gearbox technology application - EN.pdf | Commissioning |
| "Electronic Gearbox" technology application | DE | Technologieapplikation "Electronic Gearbox"_DE.pdf | Commissioning |
| "Sync and Correction" technology application | EN | Sync and Correction technology application - EN.pdf | Commissioning |
| "Sync and Correction" technology application | DE | Technologieapplikation "Sync and Correction"_DE.pdf | Commissioning |
| "Winder Tension" technology application | EN | Winder Tension technology application - EN.pdf | Commissioning |
| "Winder Tension" technology application | DE | Technologieapplikation "Winder Tension"_DE.pdf | Commissioning |
| "Table Positioning" technology application | EN | Table Positioning technology application - EN.pdf | Commissioning |
| "Table Positioning" technology application | DE | Technologieapplikation "Table Positioning"_DE.pdf | Commissioning |
| Servo inverters | ZH | Servoumrichter_ZH.pdf | Brochure |
| Servo inverters | SL | Servoumrichter_SL.pdf | Brochure |
| Servo inverters | SK | Servoumrichter_SK.pdf | Brochure |
| Servo inverters | RU | Servoumrichter_RU.pdf | Brochure |
| Servo inverters | PT | Servoumrichter_PT.pdf | Brochure |
| Servo inverters | PL | Servoumrichter_PL.pdf | Brochure |
| Servo inverters | IT | Servoumrichter_IT.pdf | Brochure |
| Servo inverters | HU | Servoumrichter_HU.pdf | Brochure |
| Servo inverters | HR | Servoumrichter_HR.pdf | Brochure |
| Servo inverters | FR | Servoumrichter_FR.pdf | Brochure |
| Servo inverters | ES | Servoumrichter_ES.pdf | Brochure |
| Servo inverters | CS | Servoumrichter_CS.pdf | Brochure |
| Servo inverters | BG | Servoumrichter_BG.pdf | Brochure |
| Servo inverters | EN | Servo inverters - EN.pdf | Brochure |
| Servo inverters | DE | Servoumrichter_DE.pdf | Brochure |
| CCC (China) | EN, DE, ZH | CCC (China)_DE-EN-ZH (2).pdf | Conformity |
| Functional safety | EN | Functional safety - EN.pdf | Manuals |
| Functional safety | DE | Funktionale Sicherheit_DE.pdf | Manuals |
| Inverters - Power losses according to Ecodesign Directive | ZH | Umrichter - Leistungsverluste nach Ökodesign-Richtlinie_ZH.pdf | Energy efficiency |
| Inverters - Power losses according to Ecodesign Directive | RU | Umrichter - Leistungsverluste nach Ökodesign-Richtlinie_RU.pdf | Energy efficiency |
| Inverters - Power losses according to Ecodesign Directive | FR | Umrichter - Leistungsverluste nach Ökodesign-Richtlinie_FR.pdf | Energy efficiency |
| Inverters - Power losses according to Ecodesign Directive | PL | Umrichter - Leistungsverluste nach Ökodesign-Richtlinie_PL.pdf | Energy efficiency |
| Inverters - Power losses according to Ecodesign Directive | CS | Umrichter - Leistungsverluste nach Ökodesign-Richtlinie_CS.pdf | Energy efficiency |
| Inverters - Power losses according to Ecodesign Directive | EN | Inverters - Power losses according to Ecodesign Directive - EN.pdf | Energy efficiency |
| Inverters - Power losses according to Ecodesign Directive | HU | Umrichter - Leistungsverluste nach Ökodesign-Richtlinie_HU.pdf | Energy efficiency |
| Inverters - Power losses according to Ecodesign Directive | IT | Umrichter - Leistungsverluste nach Ökodesign-Richtlinie_IT.pdf | Energy efficiency |
| Inverters - Power losses according to Ecodesign Directive | PT | Umrichter - Leistungsverluste nach Ökodesign-Richtlinie_PT.pdf | Energy efficiency |
| Inverters - Power losses according to Ecodesign Directive | ES | Umrichter - Leistungsverluste nach Ökodesign-Richtlinie_ES.pdf | Energy efficiency |
| Inverters - Power losses according to Ecodesign Directive | DE | Umrichter - Leistungsverluste nach Ökodesign-Richtlinie_DE.pdf | Energy efficiency |
| Accessories | ZH | Zubehör_ZH.pdf | Brochure |
| Accessories | SK | Zubehör_SK.pdf | Brochure |
| Accessories | RU | Zubehör_RU.pdf | Brochure |
| Accessories | PT | Zubehör_PT.pdf | Brochure |
| Accessories | PL | Zubehör_PL.pdf | Brochure |
| Accessories | IT | Zubehör_IT.pdf | Brochure |
| Accessories | HU | Zubehör_HU.pdf | Brochure |
| Accessories | FR | Zubehör_FR.pdf | Brochure |
| Accessories | ES | Zubehör_ES.pdf | Brochure |
| Accessories | EN | Accessories_Brochure_EN.pdf | Brochure |
| Accessories | DE | Zubehör_DE.pdf | Brochure |
| Accessories | CS | Zubehör_CS.pdf | Brochure |
-
Fault message ID
0 0x00000000 Description
CauseNo error
RemedyNo error
Severity/responseFor information only. No remedy necessary.
Information
-
Fault message ID
537469777 0x20092351 Description
CauseMotor utilization too high (i²xt)
RemedyMotor thermally overloaded, e.g. by an impermissible continuous current or by frequent or too long acceleration processes.
Severity/responseCheck drive sizing. Check the setting in the warning threshold or error threshold.
Fehler > CiA402 (configurable)
Setting parameters: 0x2D50:001
-
Fault message ID
537469824 0x20092380 Description
CauseTrouble - utilization of the power section (ixt) too high
RemedyPower section overloaded.
Severity/responseCheck drive sizing.
Fault
-
Fault message ID
537469825 0x20092381 Description
CauseWarning - Utilization of the power section (ixt) too high
RemedyPower section overloaded.
Severity/responseCheck drive sizing.
Warning
-
Fault message ID
537469828 0x20092384 Description
CauseUltimate motor current reached
RemedyUltimate motor current reached.
Severity/response- Reduce the maximum current of the inverter. 0x6073
- Optimize the current controller. 0x2942
Fault > CiA402 (configurable)
Setting parameters: 0x2D46:002
-
Fault message ID
537469829 0x20092385 Description
CauseParameterized max. motor current > max. device current
RemedyParameterized max. motor current 0x6073 > max. device current 0x2DDF:002
Severity/responseReduce max. motor current. 0x6073
Warning
-
Fault message ID
537469830 0x20092386 Description
CauseClamp is active
RemedyMax. device current has been reached. (Display in 0x2DDF:002)
Severity/response- Select a flatter speed ramp.
- Reduce the load.
- Set Imax controller more dynamically. 0x2B08
Warning
-
Fault message ID
537469833 0x20092389 Description
CauseWarning - device utilization (ixt) too high
RemedyFrequent and too long acceleration processes with overcurrent.
Severity/responseCheck drive sizing.
Warning
-
Fault message ID
537469835 0x2009238B Description
CauseTrouble - Device utilization (ixt) too high
RemedyFrequent and too long acceleration processes with overcurrent.
Severity/responseCheck drive sizing.
Fault
-
Fault message ID
537473409 0x20093181 Description
CauseMains failure
RemedyThe motor was decelerated to standstill via the mains failure control without an undervoltage fault occurring.
Severity/response- Check mains voltage.
- Check mains settings.
- Check fuses.
Fault
-
Fault message ID
537477762 0x20094282 Description
CauseThermal overload of control unit
Remedy- Control card temperature > 100 °C
- Ambient temperature too high
Severity/response- Provide for better cooling.
- Reduce ambient temperature.
Information
-
Fault message ID
537478016 0x20094380 Description
CauseFault - Motor temperature sensor
RemedyMotor PTC error.
Severity/responseConnect PTC or switch off monitoring.
Warning (configurable)
Setting parameters: 0x2D49:002
-
Fault message ID
537478017 0x20094381 Description
CauseError - Motor temperature monitoring (PTC)
RemedyMotor PTC error.
Severity/responseConnect PTC or switch off monitoring.
Fault > CiA402 (configurable)
Setting parameters: 0x2D48:002
-
Fault message ID
537478018 0x20094382 Description
CauseMotor overtemperature (load encoder/master encoder)
RemedyMotor temperature via load encoder higher than variable temperature limit.
Severity/responseConnect PTC or switch off monitoring. Set a higher warning threshold (0x2D49:003) and/or error threshold (0x2D49:004).
Warning (configurable)
Setting parameters: 0x2D49:002
-
Fault message ID
537478019 0x20094383 Description
CauseMotor temperature sensor error (load encoder/master encoder)
RemedyMotor PTC error.
Severity/responseConnect PTC or switch off monitoring.
Warning (configurable)
Setting parameters: 0x2D49:002
-
Fault message ID
537485328 0x20096010 Description
CauseInternal error
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
Fault message ID
537486096 0x20096310 Description
CauseIncorrect parameter set download
RemedyCRC error in the parameter set detected. Vendor, product code or OBD revision are different. The parameter set is unknown.
Severity/responseRecreate parameter set. Repeat parameter set download.
Warning
-
Fault message ID
537486112 0x20096320 Description
CauseParameter error in object
RemedyUnknown index in the parameter set.
Severity/responseRecreate parameter set.
Warning
-
Fault message ID
537489584 0x200970B0 Description
CauseConnected network option is not supported
RemedyThe network option plugged into the inverter is not supported by the firmware.
Severity/responseUpdate the firmware to a version that supports the network option. Use the network option supported by the current firmware version.
Fault
-
Fault message ID
537490179 0x20097303 Description
CauseFault - Motor feedback
RemedyDefective encoder cable. Defective encoder.
Severity/responseCheck encoder cable. Check encoder. Switch off monitoring if no encoder is used.
Fault > CiA402 (configurable)
Setting parameters: 0x2C45
-
Fault message ID
537490180 0x20097304 Description
CauseError - Load encoder/master encoder
RemedyDefective encoder cable. Defective encoder.
Severity/responseCheck encoder cable. Check encoder. Switch off monitoring if no encoder is used.
Fault > CiA402 (configurable)
Setting parameters: 0x2C55
-
Fault message ID
537490304 0x20097380 Description
CauseMotor encoder - Communication error
RemedyThe communication to an encoder is disturbed.
Severity/responseCheck the supply voltage of the encoder. (0x2C42:002) Check encoder cable.
Fault > CiA402 (configurable)
Setting parameters: 0x2C41:004
-
Fault message ID
537490305 0x20097381 Description
CauseMotor encoder - wrong absolute value because motor speed is too high
RemedyThe absolute encoder position cannot be accepted as the motor rotates too fast.
Severity/responseLet the motor coast.
Fault > CiA402 (configurable)
Setting parameters: 0x2C41:004
-
Fault message ID
537490306 0x20097382 Description
CauseLoad encoder/master encoder - Communication error
RemedyThe communication to an encoder is disturbed.
Severity/responseCheck the supply voltage of the encoder. (0x2C42:002) Check encoder cable.
Fault > CiA402 (configurable)
Setting parameters: 0x2C51:004
-
Fault message ID
537490307 0x20097383 Description
CauseLoad encoder/master encoder - wrong absolute value because motor speed is too high
RemedyThe absolute encoder position cannot be accepted as the motor rotates too fast.
Severity/responseLet the motor coast.
Fault > CiA402 (configurable)
Setting parameters: 0x2C51:004
-
0x1000
Parameter
Device type Data type
U32 Default setting
- (Read only) Attributes
- -
0x1001
Parameter
Error register Data type
U8 Default setting
- (Read only) Attributes
- -
0x1008
Parameter
Manufacturer device name Data type
STRING[50] Default setting
- (Read only) Attributes
- -
0x1009
Parameter
Manufacturer hardware version Data type
STRING[50] Default setting
- (Read only) Attributes
- -
0x100A
Parameter
Manufacturer software version Data type
STRING[50] Default setting
- (Read only) Attributes
- -
0x1018:001
Parameter
Identity object: Vendor ID Data type
U32 Default setting
- (Read only) Attributes
- -
0x1018:002
Parameter
Identity object: Product Code Data type
U32 Default setting
- (Read only) Attributes
- -
0x1018:003
Parameter
Identity object: Revision number Data type
U32 Default setting
- (Read only) Attributes
- -
0x1018:004
Parameter
Identity object: Serial number Data type
U32 Default setting
- (Read only) Attributes
- -
0x10F1:001
Parameter
Error settings: Local error reaction Data type
U32 Default setting
Device specific state [2] Attributes
- -
0x10F1:002
Parameter
Error settings: Sync error counter limit Data type
U16 Default setting
20 Attributes
- -
0x2000:001
Parameter
Device data: Product code Data type
STRING[50] Default setting
- (Read only) Attributes
- -
0x2000:002
Parameter
Device data: Serial number Data type
STRING[50] Default setting
- (Read only) Attributes
- -
0x2000:003
Parameter
Device data: Production date Data type
STRING[50] Default setting
- (Read only) Attributes
- -
0x2000:004
Parameter
Device data: CU firmware version Data type
STRING[50] Default setting
- (Read only) Attributes
- -
0x2000:006
Parameter
Device data: CU bootloader version Data type
STRING[50] Default setting
- (Read only) Attributes
- -
0x2000:008
Parameter
Device data: Object directory version Data type
U32 Default setting
- (Read only) Attributes
- -
0x2000:015
Parameter
Device data: Communication firmware revision number Data type
STRING[50] Default setting
- (Read only) Attributes
- -
0x2000:019
Parameter
Device data: Safety module version Data type
STRING[50] Default setting
- (Read only) Attributes
- -
0x2001
Parameter
Device name Data type
STRING[128] Default setting
"Device" Attributes
- -
0x2002:001
Parameter
Device module: Safety module Data type
STRING[50] Default setting
- (Read only) Attributes
- -
0x2002:006
Parameter
Device module: CU serial number Data type
STRING[50] Default setting
- (Read only) Attributes
- -
0x2002:007
Parameter
Device module: PU serial number Data type
STRING[50] Default setting
- (Read only) Attributes
- -
0x2002:010
Parameter
Device module: Type communication module Data type
STRING[50] Default setting
- (Read only) Attributes
- -
0x2002:011
Parameter
Device module: Serial number communication module Data type
STRING[50] Default setting
- (Read only) Attributes
-
No results.