i950
- Rated power 0.37 kW/0.5 HP
- Output current 2.4 A
- Output frequency 0-599 Hz
- Rated mains voltage 1/N(3)/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 0.55 kW/0.75 HP
- Output current 3.2 A
- Output frequency 0-599 Hz
- Rated mains voltage 1/N(3)/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 0.55 kW/0.75 HP
- Output current 1.8/1.6 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 0.75 kW/1 HP
- Output current 4.2 A
- Output frequency 0-599 Hz
- Rated mains voltage 1/N(3)/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 0.75 kW/1 HP
- Output current 2.4/2.1 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 1.5 kW/2 HP
- Output current 7 A
- Output frequency 0-599 Hz
- Rated mains voltage 1/N(3)/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 2.2 kW/3 HP
- Output current 9.6 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 2.2 kW/3 HP
- Output current 5.6/4.8 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 4 kW/5 HP
- Output current 16.5 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 4 kW/5 HP
- Output current 9.5/8.2 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 5.5 kW/7.5 HP
- Output current 23 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 7.5 kW/10 HP
- Output current 16.5/14 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 11 kW/15 HP
- Output current 23.5/21 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 15 kW/20 HP
- Output current 32/27 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 22 kW/30 HP
- Output current 47/40.4 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 30 kW/40 HP
- Output current 61/52 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 45 kW/60 HP
- Output current 89/77 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 55 kW/75 HP
- Output current 110/96 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 75 kW/100 HP
- Output current 150/124 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 90 kW/125 HP
- Output current 180/156 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 110 kW/150 HP
- Output current 212/180 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
-
Fault message ID
537526045 0x2009FF1D Description
CauseNo HIPERFACE® absolute value encoder as load encoder/master encoder connected - command cannot be
RemedyAn attempt was made to read out HIPERFACE® data although no HIPERFACE® encoder is connected. No HIPERFACE® encoder is selected in 0x2C50.
Severity/responseConnect HIPERFACE® encoder. A HIPERFACE® encoder must be selected in 0x2C50.
Warning
-
Fault message ID
537526046 0x2009FF1E Description
CauseFIQ runtime error
RemedyThe monitoring of the FIQ by the FPGA has triggered.
Severity/responseConnect an encoder with a supported type code.
Fault
-
Fault message ID
537526048 0x2009FF20 Description
CauseBrand protection - check failed
RemedyThe review of brand protection has failed.
Severity/responseEnter correct pin. Replace device with OEM device and reprogram pin.
Warning
-
Fault message ID
537526049 0x2009FF21 Description
CauseTime-out holding brake feedforward control
RemedyThe specified feedforward control torque could not be built up within one second.
Severity/response- 0x2820:009 (Starting torque source) = [0] (Last torque saved): - The load to be braked is too large. - Control the stored torque. 40x2820:021
- 0x2820:009 (Starting torque source) = [1] (Torque in 0x2820:010): - The set torque is too high. - Reduce torque.
Fault
-
Fault message ID
537526050 0x2009FF22 Description
CauseVelocity error
RemedyThe speed error exceeds the limit from 0x2D51:001 for a time duration > 0x2D51:002.
Severity/responseIncrease timeout in 0x2D51:002. Increase limit in 0x2D51:001. Increase gain of the speed controller. Increase torque limit and/or current limit.
Fault
-
Fault message ID
537526051 0x2009FF23 Description
CausePosition error
RemedyThe following error exceeds the limit from 0x2D51:004 for a time duration > 0x2D51:005.
Severity/responseIncrease timeout in 0x2D51:005. Increase limit in 0x2D51:004. Increase gain of the position controller.
Fault
-
Fault message ID
537526054 0x2009FF26 Description
CauseCable check - Motor movement too large
RemedyPhases in the motor cable reversed. The axis was moved manually. Motor parameters are set incorrectly. For synchronous motors: The pole position is set incorrectly. For motors with holding brake: The brake was opened prematurely by an external source.
Severity/responseCheck motor cabling. Avoid manual movement. Check number of pole pairs and motor type. Carry out the pole position identification Do not open the brake until you have checked the wiring.
Fault
-
Fault message ID
537526055 0x2009FF27 Description
CauseCable check - Wrong motor angle detected
RemedyThe determined angle between rotor and resolver differs from the setting in 0x2C03:002. The determined angle between rotor and encoder differs from the setting in 0x2C03:004.
Severity/responseCheck encoder cabling. Check motor cabling. If appropriate, Carry out the pole position identification
Fault
-
Fault message ID
537526062 0x2009FF2E Description
Severity/responseConnected motor encoder is not supported
Fault
-
Fault message ID
537526063 0x2009FF2F Description
Severity/responseConnected load encoder/master encoder is not supported
Fault
-
Fault message ID
537526076 0x2009FF3C Description
CauseBackup created via device command
RemedyBackup created via device command
Severity/responseFor information only. No remedy necessary.
Information
-
Fault message ID
537526077 0x2009FF3D Description
CauseBackup restored via device command
RemedyBackup restored via device command
Severity/responseFor information only. No remedy necessary.
Information
-
Fault message ID
537526080 0x2009FF40 Description
CauseError - Brake transistor
RemedyThe short-circuit monitoring of the brake transistor has triggered.
Severity/responseUse brake resistor with a greater resistance value. Use external brake chopper. Use regenerative module.
Fault
-
Fault message ID
537526081 0x2009FF41 Description
CauseError - Charging circuit
RemedyThe monitoring of the charge relay has responded.
Severity/responseAcknowledge error. If the error persists, contact the manufacturer.
Fault
-
Fault message ID
537526082 0x2009FF42 Description
CauseMains phase failure
RemedyThe mains phase monitoring has triggered.
Severity/responseCheck mains connection.
Fault
-
Fault message ID
537526083 0x2009FF43 Description
Severity/responseMotor encoder requires restart of the device
Fault
-
Fault message ID
537526084 0x2009FF44 Description
Severity/responseLoad encoder requires restart of the device
Fault
-
Fault message ID
537526096 0x2009FF50 Description
CauseGeneral error (see manual)
RemedyAn error has been triggered in the technology application, the PLC or in the network, which requires a direct error response from the drive.
Severity/response1. Search logbook for the triggering error in the other component. 2. Eliminate the triggering error. The error message can now be acknowledged. If this is not possible, contact the manufacturer.
Fault
-
Fault message ID
537526097 0x2009FF51 Description
CauseInternal communication to PLC failed
RemedyThe internal communication between the application and the base firmware is disturbed.
Severity/responseRestart device.
Fault
-
Fault message ID
537526110 0x2009FF5E Description
CauseInvalid module combination in slot A and slot B
RemedyThe modules in slot A and slot B cannot be combined.
Severity/responseRemove a module. Plug a valid module combination.
Fault
- The event can only be reset by mains switching.
-
Fault message ID
8992 0x2320 Description
Short circuit or earth leakage at the motor endKeypad display
Earth leak Cause
Remedy- Short circuit/earth fault of motor cable
- Capacitive charging current of the motor cable too high.
Severity/response- Check motor cable.
- Check length of the motor cable.
- Use shorter or lower-capacitance motor cable.
Fault
- The inverter is disabled immediately. The motor has no torque (is coasting).
- The event can only be reset after a blocking time.
-
Fault message ID
9024 0x2340 Description
Short circuit at the motor endKeypad display
Motor shorted Cause
RemedyShort circuit of motor cable
Severity/responseCheck motor cable for short circuit.
Fault
- The inverter is disabled immediately. The motor has no torque (is coasting).
- The event can only be reset after a blocking time.
-
Fault message ID
9090 0x2382 Description
Fault - Device utilization (ixt) too highKeypad display
Ixt error Cause
RemedyDevice utilisation (ixt) too high by frequent and too long acceleration processes.
Severity/responseCheck drive sizing.
- Reduce the maximum current of the inverter 0x6073 (P324.00).
- In case of high mass inertias, reduce maximum current of the inverter 0x6073 (P324.00) to 150 %.
Fault (configurable)
- The event can only be reset after a blocking time.
-
Fault message ID
9091 0x2383 Description
Keypad displayWarning - Device utilization (ixt) too high
Ixt warning Cause
RemedyDevice utilisation (ixt) too high by frequent and too long acceleration processes.
Severity/responseCheck drive dimensioning.
Warning
-
Fault message ID
9095 0x2387 Description
Keypad displayClamp responded too often
Clamp timeout Cause
RemedyMaximum current of the axis (display in 0x2DDF:002) has been reached too often in succession.
Severity/response- Select a flatter speed ramp.
- Reduce the load.
- Set Imax controller more dynamically.
Fault
-
0x2C44:012
Parameter
Motor encoder identification (Resolver): Harmonic for cyclic online compensation Data type
U16 Default setting
22 Attributes
- -
0x2C44:013
Parameter
Motor encoder identification (Resolver): Dead time compensation resolver evaluation Data type
I16 Default setting
100.0 % Attributes
- -
0x2C45
Parameter
Motor feedback error response Data type
U8 Default setting
Fault > CiA402 [1] Attributes
- -
0x2C46
Parameter
Number of the absolute ascertainable revolutions of motor encoder Data type
U16 Default setting
- (Read only) Attributes
- -
0x2C47
Parameter
Open circuit detection sensitivity of motor encoder Data type
U8 Default setting
100 % Attributes
- -
0x2C48:001
Parameter
Motor encoder (EnDat): Response communication error Data type
U8 Default setting
Fault > CiA402 [1] Attributes
- -
0x2C48:002
Parameter
Motor encoder (EnDat): Actual position (raw data) Data type
U32 Default setting
- (Read only) Attributes
- -
0x2C48:003
Parameter
Motor encoder (EnDat): Serial number Data type
STRING[50] Default setting
- (Read only) Attributes
- -
0x2C48:004
Parameter
Motor encoder (EnDat): ID number Data type
STRING[50] Default setting
- (Read only) Attributes
- -
0x2C48:005
Parameter
Motor encoder (EnDat): Encoder designation Data type
STRING[50] Default setting
- (Read only) Attributes
- -
0x2C48:006
Parameter
Motor encoder (EnDat): EnDat ordering designation Data type
STRING[50] Default setting
- (Read only) Attributes
- -
0x2C48:007
Parameter
Motor encoder (EnDat): EnDat command set Data type
STRING[50] Default setting
- (Read only) Attributes
- -
0x2C48:008
Parameter
Motor encoder (EnDat): Encoder type Data type
U8 Default setting
- (Read only) Attributes
- -
0x2C48:009
Parameter
Motor encoder (EnDat): Signal periods per revolution/Length of signal period Data type
U32 Default setting
- (Read only) Attributes
- -
0x2C48:010
Parameter
Motor encoder (EnDat): Distinguishable revolutions Data type
U16 Default setting
- (Read only) Attributes
- -
0x2C48:011
Parameter
Motor encoder (EnDat): Max. clock frequency Data type
U16 Default setting
x kHz (Read only) Attributes
- -
0x2C48:012
Parameter
Motor encoder (EnDat): Measuring step or measuring steps/rev for serial data transmission Data type
U32 Default setting
- (Read only) Attributes
- -
0x2C48:013
Parameter
Motor encoder (EnDat): Scaling factor for resolution Data type
U16 Default setting
- (Read only) Attributes
- -
0x2C48:014
Parameter
Motor encoder (EnDat): Measuring step, or measuring steps/rev or subdivision values of a grating period Data type
U32 Default setting
- (Read only) Attributes
- -
0x2C4A:001
Parameter
Motor encoder (SSI) protocol parameters: Bit rate Data type
U16 Default setting
300 kbps Attributes
C -
0x2C4A:002
Parameter
Motor encoder (SSI) protocol parameters: Telegram length Data type
U8 Default setting
25 Attributes
C -
0x2C4A:003
Parameter
Motor encoder (SSI) protocol parameters: Bits/ revolution Data type
U8 Default setting
13 Attributes
C -
0x2C4A:004
Parameter
Motor encoder (SSI) protocol parameters: Position data start bit Data type
U8 Default setting
0 Attributes
C -
0x2C4A:005
Parameter
Motor encoder (SSI) protocol parameters: Data package 1 start bit Data type
U8 Default setting
0 Attributes
C -
0x2C4A:006
Parameter
Motor encoder (SSI) protocol parameters: Data package 2 start bit Data type
U8 Default setting
0 Attributes
C
No results.