i950

i950-C0.37/230-2 i950-C0.37/230-2 Description
Lenze logo Order code / SKU
On request
  • Rated power 0.37 kW/0.5 HP
  • Output current 2.4 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 1/N(3)/PE 230/240 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter not integrated
i950-C0.55/230-2 i950-C0.55/230-2 Description
Lenze logo Order code / SKU
On request
  • Rated power 0.55 kW/0.75 HP
  • Output current 3.2 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 1/N(3)/PE 230/240 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter not integrated
i950-C0.55/400-3 i950-C0.55/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 0.55 kW/0.75 HP
  • Output current 1.8/1.6 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter Integrated
i950-C0.75/230-2 i950-C0.75/230-2 Description
Lenze logo Order code / SKU
On request
  • Rated power 0.75 kW/1 HP
  • Output current 4.2 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 1/N(3)/PE 230/240 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter not integrated
i950-C0.75/400-3 i950-C0.75/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 0.75 kW/1 HP
  • Output current 2.4/2.1 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter Integrated
i950-C1.5/230-2 i950-C1.5/230-2 Description
Lenze logo Order code / SKU
On request
  • Rated power 1.5 kW/2 HP
  • Output current 7 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 1/N(3)/PE 230/240 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter not integrated
i950-C2.2/230-3 i950-C2.2/230-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 2.2 kW/3 HP
  • Output current 9.6 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 230/240 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter not integrated
i950-C2.2/400-3 i950-C2.2/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 2.2 kW/3 HP
  • Output current 5.6/4.8 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter Integrated
i950-C4/230-3 i950-C4/230-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 4 kW/5 HP
  • Output current 16.5 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 230/240 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter not integrated
i950-C4/400-3 i950-C4/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 4 kW/5 HP
  • Output current 9.5/8.2 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter Integrated
i950-C5.5/230-3 i950-C5.5/230-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 5.5 kW/7.5 HP
  • Output current 23 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 230/240 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter not integrated
i950-C7.5/400-3 i950-C7.5/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 7.5 kW/10 HP
  • Output current 16.5/14 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter Integrated
i950-C11/400-3 i950-C11/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 11 kW/15 HP
  • Output current 23.5/21 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter Integrated
i950-C15/400-3 i950-C15/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 15 kW/20 HP
  • Output current 32/27 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter Integrated
i950-C22/400-3 i950-C22/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 22 kW/30 HP
  • Output current 47/40.4 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter Integrated
i950-C30/400-3 i950-C30/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 30 kW/40 HP
  • Output current 61/52 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter Integrated
i950-C45/400-3 i950-C45/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 45 kW/60 HP
  • Output current 89/77 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter Integrated
i950-C55/400-3 i950-C55/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 55 kW/75 HP
  • Output current 110/96 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter Integrated
i950-C75/400-3 i950-C75/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 75 kW/100 HP
  • Output current 150/124 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter Integrated
i950-C90/400-3 i950-C90/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 90 kW/125 HP
  • Output current 180/156 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter Integrated
i950-C110/400-3 i950-C110/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 110 kW/150 HP
  • Output current 212/180 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter Integrated
Showing 551–563 of 563
  • Fault message ID
    33170
    0x8192 Description

    Network - Initialization error

    Keypad display
    Net. Init. error
    Cause

    The initialisation of the communication stack has been interrupted due to an incorrect address setting or communication configuration.

    Remedy

    Check master/slave configuration and restart the devices.

    Severity/response

    Trouble (configurable)

  • Fault message ID
    33171
    0x8193 Description

    Network - Invalid cyclic process data

    Keypad display
    Inv. cyclic data
    Cause

    The cyclic process data received are invalid.

    Remedy

    Check cyclic process data sent by the master.

    Severity/response

    Trouble (configurable)

  • Fault message ID
    33414
    0x8286 Description

    Network - PDO mapping error

    Keypad display
    PDO map error
    Cause
    • Invalid PDO assignment by the master.
    • Internal PDO assignment was changed and does not comply with the configuration available in the master.
    Remedy

    Check data mapping in the master and slave.

    Severity/response

    Trouble (configurable) Setting parameters: 0x2859:003 (P515.03)

  • Fault message ID
    33425
    0x8291 Description

    CAN: RPDO1 time-out

    Keypad display
    Timeout RPDO1
    Cause

    RPDO1 was not received within the time-out period set in 0x1400:005 (P540.05) or with the sync configured.

    Severity/response

    Fault (configurable)

  • Fault message ID
    33426
    0x8292 Description

    CAN: RPDO2 time-out

    Keypad display
    Timeout RPDO2
    Cause

    RPDO2 was not received within the time-out period set in 0x1401:005 (P541.05) or with the sync configured.

    Severity/response

    Fault (configurable)

  • Fault message ID
    33427
    0x8293 Description

    CAN: RPDO3 time-out

    Keypad display
    Timeout RPDO3
    Cause

    RPDO3 was not received within the time-out period set in 0x1402:005 (P542.05) or with the sync configured.

    Severity/response

    Fault (configurable)

  • Fault message ID
    65286
    0xFF06 Description

    Motor overspeed

    Keypad display
    Motor overspeed
    Cause

    The motor speed has reached the error threshold for overspeed set in 0x2D44:001 (P350.01).

    Remedy

    Adapt the maximum motor speed 0x6080 (P322.00) and the warning threshold or error threshold 0x2D44:001 (P350.01).

    Severity/response

    Fault (configurable)

    • The event can only be reset after a blocking time. Setting parameters: 0x2D44:002 (P350.02)
  • Fault message ID
    65289
    0xFF09 Description

    Motor phase missing

    Keypad display
    Mot.Phase miss.
    Cause

    A failure of several motor phases has been detected.

    Remedy
    • Check wiring between inverter and motor.
    • In case of a false tripping, adapt the settings for the motor phase failure detection.
    Severity/response

    No response (configurable)

    • The event can only be reset after a blocking time. Setting parameters: 0x2D45:001 (P310.01)
  • Fault message ID
    65290
    0xFF0A Description

    Motor phase failure phase U

    Keypad display
    Phase U failure
    Cause

    A failure of the motor phase U has been detected.

    Remedy
    • Check wiring between inverter and motor.
    • In case of a false tripping, adapt the settings for the motor phase failure detection. - 0x2D45:002 (P310.02) (Current threshold) - 0x2D45:003 (P310.03) (Voltage threshold)
    Severity/response

    No response (configurable)

    • The event can only be reset after a blocking time. Setting parameters: 0x2D45:001 (P310.01)
  • Fault message ID
    65291
    0xFF0B Description

    Motor phase failure phase V

    Keypad display
    Phase V failure
    Cause

    A failure of the motor phase V has been detected.

    Remedy
    • Check wiring between inverter and motor.
    • In case of a false tripping, adapt the settings for the motor phase failure detection. - 0x2D45:002 (P310.02) (Current threshold) - 0x2D45:003 (P310.03) (Voltage threshold)
    Severity/response

    No response (configurable)

    • The event can only be reset after a blocking time. Setting parameters: 0x2D45:001 (P310.01)
  • Fault message ID
    65292
    0xFF0C Description

    Motor phase failure phase W

    Keypad display
    Phase W failure
    Cause

    A failure of the motor phase W has been detected.

    Remedy
    • Check wiring between inverter and motor.
    • In case of a false tripping, adapt the settings for the motor phase failure detection. - 0x2D45:002 (P310.02) (Current threshold) - 0x2D45:003 (P310.03) (Voltage threshold)
    Severity/response

    No response (configurable)

    • The event can only be reset after a blocking time. Setting parameters: 0x2D45:001 (P310.01)
  • Fault message ID
    65305
    0xFF19 Description

    Motor parameter identification fault

    Keypad display
    Motor ID fault
    Cause

    During the automatic identification of the motor, an error has occurred.

    Remedy
    • Set motor data so that they comply with the data on the motor nameplate.
    • Check wiring of the motor.
    Severity/response

    Fault

  • Fault message ID
    65334
    0xFF36 Description

    Warning - Brake resistor overload

    Keypad display
    BrkResistor OL.W
    Cause

    The calculated thermal load of the brake resistor has reached the warning threshold set in 0x2550:008 (P707.08). The regenerative energy is too high.

    Remedy
    • Check drive dimensioning.
    • Check settings for the brake energy management. Note: The warning status is reset if the thermal load falls below the warning threshold of - 20 %.
    Severity/response

    Warning (configurable) Setting parameters: 0x2550:010 (P707.10)

← Previous Page 23 of 23

No results.