i550

i550-C0.25/120-1 i550-C0.25/120-1 Description
Lenze logo Order code / SKU
On request
  • Rated power 0.25 kW/0.33 HP
  • Output current 1.7 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 1/N/PE 120 V AC
  • Motor output Single axis
  • Generation A
  • Product series i550 cabinet
  • EMC filter not integrated
i550-C0.25/230-1 i550-C0.25/230-1 Description
Lenze logo Order code / SKU
On request
  • Rated power 0.25 kW/0.33 HP
  • Output current 1.7 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 1/N/PE 230/240 V AC
  • Motor output Single axis
  • Generation A
  • Product series i550 cabinet
  • EMC filter Integrated
i550-C0.25/230-2 i550-C0.25/230-2 Description
Lenze logo Order code / SKU
On request
  • Rated power 0.25 kW/0.33 HP
  • Output current 1.7 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 1/N(3)/PE 230/240 V AC
  • Motor output Single axis
  • Generation A
  • Product series i550 cabinet
  • EMC filter not integrated
i550-C0.37/120-1 i550-C0.37/120-1 Description
Lenze logo Order code / SKU
On request
  • Rated power 0.37 kW/0.5 HP
  • Output current 2.4 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 1/N/PE 120 V AC
  • Motor output Single axis
  • Generation A
  • Product series i550 cabinet
  • EMC filter not integrated
i550-C0.37/230-1 i550-C0.37/230-1 Description
Lenze logo Order code / SKU
On request
  • Rated power 0.37 kW/0.5 HP
  • Output current 2.4 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 1/N/PE 230/240 V AC
  • Motor output Single axis
  • Generation A
  • Product series i550 cabinet
  • EMC filter Integrated
i550-C0.37/230-2 i550-C0.37/230-2 Description
Lenze logo Order code / SKU
On request
  • Rated power 0.37 kW/0.5 HP
  • Output current 2.4 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 1/N(3)/PE 230/240 V AC
  • Motor output Single axis
  • Generation A
  • Product series i550 cabinet
  • EMC filter not integrated
i550-C0.37/400-3 i550-C0.37/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 0.37 kW/0.5 HP
  • Output current 1.3/1.1 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation A
  • Product series i550 cabinet
  • EMC filter Integrated
i550-C0.55/230-1 i550-C0.55/230-1 Description
Lenze logo Order code / SKU
On request
  • Rated power 0.55 kW/0.75 HP
  • Output current 3.2 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 1/N/PE 230/240 V AC
  • Motor output Single axis
  • Generation A
  • Product series i550 cabinet
  • EMC filter Integrated
i550-C0.55/230-2 i550-C0.55/230-2 Description
Lenze logo Order code / SKU
On request
  • Rated power 0.55 kW/0.75 HP
  • Output current 3.2 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 1/N(3)/PE 230/240 V AC
  • Motor output Single axis
  • Generation A
  • Product series i550 cabinet
  • EMC filter not integrated
i550-C0.55/400-3 i550-C0.55/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 0.55 kW/0.75 HP
  • Output current 1.8/1.6 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation A
  • Product series i550 cabinet
  • EMC filter Integrated
i550-C0.75/120-1 i550-C0.75/120-1 Description
Lenze logo Order code / SKU
On request
  • Rated power 0.75 kW/1 HP
  • Output current 4.2 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 1/N/PE 120 V AC
  • Motor output Single axis
  • Generation A
  • Product series i550 cabinet
  • EMC filter not integrated
i550-C0.75/230-1 i550-C0.75/230-1 Description
Lenze logo Order code / SKU
On request
  • Rated power 0.75 kW/1 HP
  • Output current 4.2 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 1/N/PE 230/240 V AC
  • Motor output Single axis
  • Generation A
  • Product series i550 cabinet
  • EMC filter Integrated
i550-C0.75/230-2 i550-C0.75/230-2 Description
Lenze logo Order code / SKU
On request
  • Rated power 0.75 kW/1 HP
  • Output current 4.2 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 1/N(3)/PE 230/240 V AC
  • Motor output Single axis
  • Generation A
  • Product series i550 cabinet
  • EMC filter not integrated
i550-C0.75/400-3 i550-C0.75/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 0.75 kW/1 HP
  • Output current 2.4/2.1 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation A
  • Product series i550 cabinet
  • EMC filter Integrated
i550-C1.1/120-1 i550-C1.1/120-1 Description
Lenze logo Order code / SKU
On request
  • Rated power 1.1 kW/1.5 HP
  • Output current 6 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 1/N/PE 120 V AC
  • Motor output Single axis
  • Generation A
  • Product series i550 cabinet
  • EMC filter not integrated
i550-C1.1/230-1 i550-C1.1/230-1 Description
Lenze logo Order code / SKU
On request
  • Rated power 1.1 kW/1.5 HP
  • Output current 6 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 1/N/PE 230/240 V AC
  • Motor output Single axis
  • Generation A
  • Product series i550 cabinet
  • EMC filter Integrated
i550-C1.1/230-2 i550-C1.1/230-2 Description
Lenze logo Order code / SKU
On request
  • Rated power 1.1 kW/1.5 HP
  • Output current 6 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 1/N(3)/PE 230/240 V AC
  • Motor output Single axis
  • Generation A
  • Product series i550 cabinet
  • EMC filter not integrated
i550-C1.1/400-3 i550-C1.1/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 1.1 kW/1.5 HP
  • Output current 3.2/3 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation A
  • Product series i550 cabinet
  • EMC filter Integrated
i550-C1.5/230-1 i550-C1.5/230-1 Description
Lenze logo Order code / SKU
On request
  • Rated power 1.5 kW/2 HP
  • Output current 7 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 1/N/PE 230/240 V AC
  • Motor output Single axis
  • Generation A
  • Product series i550 cabinet
  • EMC filter Integrated
i550-C1.5/230-2 i550-C1.5/230-2 Description
Lenze logo Order code / SKU
On request
  • Rated power 1.5 kW/2 HP
  • Output current 7 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 1/N(3)/PE 230/240 V AC
  • Motor output Single axis
  • Generation A
  • Product series i550 cabinet
  • EMC filter not integrated
i550-C1.5/400-3 i550-C1.5/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 1.5 kW/2 HP
  • Output current 3.9/3.5 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation A
  • Product series i550 cabinet
  • EMC filter Integrated
i550-C2.2/230-1 i550-C2.2/230-1 Description
Lenze logo Order code / SKU
On request
  • Rated power 2.2 kW/3 HP
  • Output current 9.6 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 1/N/PE 230/240 V AC
  • Motor output Single axis
  • Generation A
  • Product series i550 cabinet
  • EMC filter Integrated
i550-C2.2/230-2 i550-C2.2/230-2 Description
Lenze logo Order code / SKU
On request
  • Rated power 2.2 kW/3 HP
  • Output current 9.6 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 1/N(3)/PE 230/240 V AC
  • Motor output Single axis
  • Generation A
  • Product series i550 cabinet
  • EMC filter not integrated
i550-C2.2/400-3 i550-C2.2/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 2.2 kW/3 HP
  • Output current 5.6/4.8 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation A
  • Product series i550 cabinet
  • EMC filter Integrated
Page 1 of 2 Next →
Showing 101–120 of 120
  • Fault message ID
    65289
    0xFF09 Description

    Motor phase missing

    Keypad display
    Mot.Phase miss.
    Cause

    A failure of several motor phases has been detected.

    Remedy
    • Check wiring between inverter and motor.
    • In case of a false tripping, adapt the settings for the motor phase failure detection.
    Severity/response

    No response (configurable)

    • The event can only be reset after a blocking time. Setting parameters: 0x2D45:001 (P310.01)
  • Fault message ID
    65290
    0xFF0A Description

    Motor phase failure phase U

    Keypad display
    Phase U failure
    Cause

    A failure of the motor phase U has been detected.

    Remedy
    • Check wiring between inverter and motor.
    • In case of a false tripping, adapt the settings for the motor phase failure detection. - 0x2D45:002 (P310.02) (Current threshold) - 0x2D45:003 (P310.03) (Voltage threshold)
    Severity/response

    No response (configurable)

    • The event can only be reset after a blocking time. Setting parameters: 0x2D45:001 (P310.01)
  • Fault message ID
    65291
    0xFF0B Description

    Motor phase failure phase V

    Keypad display
    Phase V failure
    Cause

    A failure of the motor phase V has been detected.

    Remedy
    • Check wiring between inverter and motor.
    • In case of a false tripping, adapt the settings for the motor phase failure detection. - 0x2D45:002 (P310.02) (Current threshold) - 0x2D45:003 (P310.03) (Voltage threshold)
    Severity/response

    No response (configurable)

    • The event can only be reset after a blocking time. Setting parameters: 0x2D45:001 (P310.01)
  • Fault message ID
    65292
    0xFF0C Description

    Motor phase failure phase W

    Keypad display
    Phase W failure
    Cause

    A failure of the motor phase W has been detected.

    Remedy
    • Check wiring between inverter and motor.
    • In case of a false tripping, adapt the settings for the motor phase failure detection. - 0x2D45:002 (P310.02) (Current threshold) - 0x2D45:003 (P310.03) (Voltage threshold)
    Severity/response

    No response (configurable)

    • The event can only be reset after a blocking time. Setting parameters: 0x2D45:001 (P310.01)
  • Fault message ID
    65305
    0xFF19 Description

    Motor parameter identification fault

    Keypad display
    Motor ID fault
    Cause

    During the automatic identification of the motor, an error has occurred.

    Remedy
    • Set motor data so that they comply with the data on the motor nameplate.
    • Check wiring of the motor.
    Severity/response

    Fault

  • Fault message ID
    65311
    0xFF1F Description

    FMF Error

    Keypad display
    FMF Error
    Cause

    Configuration or runtime error

    Remedy
    • Check configuration
    • Check FMF error code 0x4050:002 to determine the error cause.
    Severity/response

    Fault

  • Fault message ID
    65317
    0xFF25 Description

    Cascading overload

    Keypad display
    Cascad. overload
    Cause

    Cascade function for pumps and fans The maximum frequency in 0x2916 (P211.00) has been reached and no free additional pump is available.

    Remedy
    • Check configuration of the cascade function.
    • Check drive sizing.
    Severity/response

    Warning

  • Fault message ID
    65334
    0xFF36 Description

    Warning - Brake resistor overload

    Keypad display
    BrkResistor OL.W
    Cause

    The calculated thermal load of the brake resistor has reached the warning threshold set in 0x2550:008 (P707.08). The regenerative energy is too high.

    Remedy
    • Check drive dimensioning.
    • Check settings for the brake energy management. Note: The warning status is reset if the thermal load falls below the warning threshold of - 20 %.
    Severity/response

    Warning (configurable) Setting parameters: 0x2550:010 (P707.10)

  • Fault message ID
    65335
    0xFF37 Description

    Automatic start disabled

    Keypad display
    Auto start disab
    Cause

    At mains connection, a start command was already available and the automatic start at power-up is set in 0x2838:002 (P203.02) to "Off [0]".

    Remedy

    Deactivate starting command and reset error.

    Severity/response

    Fault

  • Fault message ID
    65336
    0xFF38 Description

    Load loss detected

    Keypad display
    Load loss
    Cause

    In a running motor, the motor load (current) is monitored. When the motor load falls below the threshold value specified in Load loss detection: threshold (0x4006:001 (P710.01)) for the period of time specified in Load loss detection: delay time (0x4006:002 (P710.02)), load loss protection is triggered.

    Remedy

    Check utilisation

    Severity/response

    No response (configurable) Setting parameters: 0x4006:003 (P710.03)

  • Fault message ID
    65337
    0xFF39 Description

    Motor overload

    Keypad display
    Motor overload
    Cause

    If the apparent motor current exceeds a defined threshold value 0x4007:002 for a certain amount of time 0x4007:001, heavy duty monitoring is triggered.

    Remedy

    Check the motor load.

    Severity/response

    No response (configurable) Setting parameters: 0x4007:003

  • Fault message ID
    65366
    0xFF56 Description

    Maximum motor frequency reached

    Keypad display
    Max. motor freq.
    Cause
    • The limitation of the maximum motor speed set in 0x6080 (P322.00) is active.
    • The maximum output frequency of the inverter has been reached.
    • Depending on the parameter setting of 0x2D44:001 (P350.01) (Overspeed monitoring: threshold), the speed limitation (0x6080 / Max. motor speed) may become active before speed monitoring.
    Remedy

    Check application.

    Severity/response

    Warning

  • Fault message ID
    65370
    0xFF5A Description

    Manual mode disabled

    Keypad display
    Man. mode disabl
    Cause

    Indicates the deactivation of the manual speed control.

    Severity/response

    Warning

  • Fault message ID
    65371
    0xFF5B Description

    Manual mode activated

    Keypad display
    Man. mode act.
    Cause

    Indicates the activation of the manual speed control.

    Severity/response

    Warning

  • Fault message ID
    65372
    0xFF5C Description

    Manual mode time-out

    Keypad display
    ManMode time-out
    Cause

    If "manual operation" is active, an error is generated in case the communication links get lost.

    Remedy

    The error can be only be reset if the connection is restored or the control mode is changed to a different value than "manual operation".

    Severity/response

    Fault

  • Fault message ID
    65393
    0xFF71 Description

    Wrong password

    Keypad display
    Wrong password
    Cause

    A wrong password has been entered several times.

    Remedy

    Wait until the blocking time has elapsed and then enter the correct password.

    Severity/response

    Warning

    • The blocking time for entering a password is more than 10 seconds. (The blocking time is doubled every time an incorrect password is entered.)
    • No password can be entered as long as the blocking time is active.
  • Fault message ID
    65394
    0xFF72 Description

    Brand protection - not compatible

    Keypad display
    Warning
    Cause

    Inverter is not compatible with the Controller/PLC (brand protection).

    • The Controller has not written a deactivation password in the parameter yet.
    • The deactivation password written by the Controller is incorrect.
    Remedy

    Use corresponding (compatible) OEM components.

    Severity/response

    Warning

    • No response from the inverter.
    • The decision on whether the machine will be commissioned or not is made by the Controller.
  • Fault message ID
    65395
    0xFF73 Description

    Fatal Error

    Keypad display
    Fatal Error
    Cause

    Error when reading the data from the control unit.

    Remedy
    • Switch inverter off and on again.
    • If the error occurs again, the manufacturer must be contacted, since the control unit or the device has to be replaced.
    Severity/response

    Fault

    • Operation of the inverter is not possible.
  • Fault message ID
    65396
    0xFF74 Description

    Power unit fatal error

    Keypad display
    PU fatal error
    Cause

    Error when reading the data from the power unit.

    Remedy
    • Switch inverter off and on again.
    • If the error occurs again, the manufacturer must be contacted, since the power unit or the device has to be replaced.
    Severity/response

    Fault

    • Operation of the inverter is not possible.
  • Fault message ID
    65413
    0xFF85 Description

    Keypad full control active

    Keypad display
    Keypad full ctrl
    Cause

    If the "Keypad Full Control" control mode is active.

    Remedy

    To exit the control mode, press the keypad key CTRL.

    Severity/response

    Warning

    • Both the activity of controlling and the setpoint selection are carried out via the keypad.
← Previous Page 5 of 5