0x2DA2:002 Output power: Apparent power P108.02 I32 x.xxx kVA (Read only) general Lenze i550
0x2DA3:001 Output energy: Motor P109.01 I32 x.xx kWh (Read only) general Lenze i550
0x2DA3:002 Output energy: Generator P109.02 I32 x.xx kWh (Read only) general Lenze i550
0x2DA3:003 Output energy: Overall energy I32 0.00 kWh - Lenze i950
0x2DA4:001 Diagnostics of analog input 1: Value in percent I16 x.x % (Read only) - Lenze i950, i550
0x2DA4:002 Diagnostics of analog input 1: Frequency value P110.02 I16 x.x Hz (Read only) general Lenze i550
0x2DA4:003 Diagnostics of analog input 1: Process controller value P110.03 I16 x.xx PID unit (Read only) general Lenze i550
0x2DA4:004 Diagnostics of analog input 1: Torque value P110.04 I16 x.x % (Read only) general Lenze i550
0x2DA4:005 Diagnostics of analog input 1: Scaled percent value I16 x.xx % (Read only) - Lenze i950
0x2DA4:016 Diagnostics of analog input 1: Status U16 - (Read only) H Lenze i950, i550
0x2DA5:001 Diagnostics of analog input 2: Value in percent I16 x.x % (Read only) - Lenze i950, i550
0x2DA5:002 Diagnostics of analog input 2: Frequency value P111.02 I16 x.x Hz (Read only) general Lenze i550
0x2DA5:003 Diagnostics of analog input 2: Process controller value P111.03 I16 x.xx PID unit (Read only) general Lenze i550
0x2DA5:004 Diagnostics of analog input 2: Torque value P111.04 I16 x.x % (Read only) general Lenze i550
0x2DA5:005 Diagnostics of analog input 2: Scaled percent value I16 x.xx % (Read only) - Lenze i950
0x2DA5:016 Diagnostics of analog input 2: Status U16 - (Read only) H Lenze i950, i550
0x2DAA:001 Diagnostics of analog output 1: Voltage U16 x.xx V (Read only) - Lenze i950, i550
0x2DAA:002 Diagnostics of analog output 1: Current P112.02 U16 x.xx mA (Read only) general Lenze i550
0x2DAB:001 Diagnostics of analog output 2: Voltage P113.01 U16 x.xx V (Read only) Appl. I/O Lenze i550
0x2DAB:002 Diagnostics of analog output 2: Current P113.02 U16 x.xx mA (Read only) Appl. I/O Lenze i550
0x2DAC Keypad status P119.00 U16 - (Read only) general Lenze i550
0x2DAD Internal hardware states P120.00 U16 - (Read only) general Lenze i550
0x2DAE:001 Sequencer diagnostics: Active step P140.01 U8 - (Read only) Sequencer Lenze i550
0x2DAE:002 Sequencer diagnostics: Step time elapsed P140.02 I32 x.x s (Read only) Sequencer Lenze i550
0x2DAE:003 Sequencer diagnostics: Step time remaining P140.03 I32 x.x s (Read only) Sequencer Lenze i550
0x2DAE:004 Sequencer diagnostics: Steps complete P140.04 I32 - (Read only) Sequencer Lenze i550
0x2DAE:005 Sequencer diagnostics: Steps remaining P140.05 I32 - (Read only) Sequencer Lenze i550
0x2DAE:006 Sequencer diagnostics: Active sequence P140.06 U8 - (Read only) Sequencer Lenze i550
0x2DAE:007 Sequencer diagnostics: Active segment P140.07 U8 - (Read only) Sequencer Lenze i550
0x2DAE:008 Sequencer diagnostics: Relative sequence time remaining P140.08 U8 x % (Read only) Sequencer Lenze i550
0x2DAE:009 Sequencer diagnostics: Absolute sequence time remaining P140.09 I32 x.x s (Read only) Sequencer Lenze i550
0x2DAE:010 Sequencer diagnostics: Frequency setpoint I16 x.x Hz (Read only) Sequencer Lenze i550
0x2DAE:011 Sequencer diagnostics: PID setpoint I16 x.xx PID unit (Read only) Sequencer Lenze i550
0x2DAE:012 Sequencer diagnostics: Torque setpoint I16 x.x % (Read only) Sequencer Lenze i550
0x2DD0:001 Field values: Actual value U16 x % (Read only) - Lenze i950
0x2DD0:002 Field values: Setpoint value U16 x % (Read only) - Lenze i950
0x2DD1:001 Motor currents: Actual D-current (id) I32 x.xx A (Read only) - Lenze i950, i550
0x2DD1:002 Motor currents: Actual Q-current (iq) I32 x.xx A (Read only) - Lenze i950, i550
0x2DD1:003 Motor currents: Setpoint D-current (id) I32 x.xx A (Read only) - Lenze i950, i550
0x2DD1:004 Motor currents: Setpoint Q-current (iq) I32 x.xx A (Read only) - Lenze i950, i550
0x2DD1:005 Motor currents: Motor current (Ieff) I32 x.xx A (Read only) - Lenze i950, i550
0x2DD2 Target position interpolated I32 - (Read only) - Lenze i950
0x2DD3:001 Speed setpoints: Speed setpoint I32 x rpm (Read only) - Lenze i950
0x2DD3:002 Speed setpoints: Speed setpoint 2 I32 x rpm (Read only) - Lenze i950
0x2DD3:003 Speed setpoints: Speed setpoint limited I32 x rpm (Read only) - Lenze i950, i550
0x2DD4:001 Speed controller output signals: Output signal 1 I16 x.x % (Read only) - Lenze i950
0x2DD4:002 Speed controller output signals: Output signal 2 I16 x.x % (Read only) - Lenze i950
0x2DD5 Torque setpoint I32 x.xx Nm (Read only) - Lenze i950, i550
0x2DD6:001 Torque filter cascade: Starting value I16 x.x % (Read only) - Lenze i950
0x2DD6:002 Torque filter cascade: Notch filter 1 input value I16 x.x % (Read only) - Lenze i950