| Title | Parameter | Display Code | Data type | Default setting | Attributes | Fieldbus | Manufacturer | Product category | Operations |
|---|---|---|---|---|---|---|---|---|---|
| 0x2DD6:003 | Torque filter cascade: Notch filter 2 input value | I16 | x.x % (Read only) | - | Lenze | i950 | |||
| 0x2DD6:004 | Torque filter cascade: Torque setpoint filtered | I16 | x.x % (Read only) | - | Lenze | i950 | |||
| 0x2DD7:001 | Voltage values: Actual voltage (motor voltage limit) | I16 | x.x V (Read only) | - | Lenze | i950 | |||
| 0x2DD7:002 | Voltage values: Output signal D current controller | I16 | x.x V (Read only) | - | Lenze | i950 | |||
| 0x2DD7:003 | Voltage values: Output signal Q current controller | I16 | x.x V (Read only) | - | Lenze | i950 | |||
| 0x2DD7:004 | Voltage values: D voltage (magnetisation) | I16 | x.x V (Read only) | - | Lenze | i950 | |||
| 0x2DD7:005 | Voltage values: Q voltage (torque) | I16 | x.x V (Read only) | - | Lenze | i950 | |||
| 0x2DD7:006 | Voltage values: Phases U-V | I16 | x.x V (Read only) | - | Lenze | i950 | |||
| 0x2DD7:007 | Voltage values: Phases V-W | I16 | x.x V (Read only) | - | Lenze | i950 | |||
| 0x2DD7:008 | Voltage values: Phases W-U | I16 | x.x V (Read only) | - | Lenze | i950 | |||
| 0x2DD7:009 | Voltage values: Phase U | I16 | x.x V (Read only) | - | Lenze | i950 | |||
| 0x2DD7:010 | Voltage values: Phase V | I16 | x.x V (Read only) | - | Lenze | i950 | |||
| 0x2DD7:011 | Voltage values: Phase W | I16 | x.x V (Read only) | - | Lenze | i950 | |||
| 0x2DDC | Actual slip value | I16 | x.x Hz (Read only) | - | Lenze | i950 | |||
| 0x2DDD | Output frequency | I16 | x.x Hz (Read only) | - | Lenze | i950, i550 | |||
| 0x2DDE | Actual rotor angle position | I16 | - (Read only) | - | Lenze | i950 | |||
| 0x2DDF:001 | Axis information: Rated current | U16 | x.xx A (Read only) | - | Lenze | i950, i550 | |||
| 0x2DDF:002 | Axis information: Maximum current | U16 | x.xx A (Read only) | - | Lenze | i950, i550 | |||
| 0x2DDF:005 | Axis information: Detected module in slot A | U8 | - (Read only) | - | Lenze | i950 | |||
| 0x2DDF:006 | Axis information: Detected module in slot B | U8 | - (Read only) | - | Lenze | i950 | |||
| 0x2DDF:007 | Axis information: Function of X109 | U8 | - (Read only) | - | Lenze | i950 | |||
| 0x2DE0:001 | Current controller identification settings | U8 | Automatic [0] | - | Lenze | i950 | |||
| 0x2DE0:003 | Resolver - position detection dynamics | U16 | 100 % | - | Lenze | i950 | |||
| 0x2DE0:004 | Resolver - 8 kHz safety signal | U8 | Automatic by device type [0] | - | Lenze | i950 | |||
| 0x2DE0:006 | OEM service Data - SN | U32 | - (Read only) | - | Lenze | i950 | |||
| 0x2DE0:007 | Use measured voltage | U8 | On [1] | - | Lenze | i950 | |||
| 0x2DE0:009 | Motor identification settings | U32 | - (Read only) | - | Lenze | i950, i550 | |||
| 0x2DE0:010 | Service settings: Motor control behavior | U16 | 0 | general | Lenze | i550 | |||
| 0x2DE0:014 | Overwrite bit 4 of CiA control word | U8 | No overwrite [0] | - | Lenze | i950 | |||
| 0x2DE0:026 | Actual speed filter time | U16 | 10.0 ms | - | Lenze | i950 | |||
| 0x2DE1:001 | Axis settings: Function of X109 | U8 | PTC [20] | - | Lenze | i950 | |||
| 0x4000 | Application selection | U16 | CiA 402 [0] | C | Lenze | i950 | |||
| 0x4002 | Speed display scaling | P702.00 | U16 | 0.00 | general | Lenze | i550 | ||
| 0x4003 | MOP starting mode | P413.00 | U8 | Last value [0] | general | Lenze | i550 | ||
| 0x4004:001 | MOP starting values: Frequency | P414.01 | U16 | 0.0 Hz | general | Lenze | i550 | ||
| 0x4004:002 | MOP starting values: PID value | P414.02 | I16 | 0.00 PID unit | general | Lenze | i550 | ||
| 0x4004:003 | MOP starting values: Torque | P414.03 | U16 | 0.0 % | general | Lenze | i550 | ||
| 0x4005 | Frequency threshold | P412.00 | U16 | 0.0 Hz | general | Lenze | i550 | ||
| 0x4006:001 | Load loss detection: Threshold | P710.01 | U16 | 0.0 % | general | Lenze | i550 | ||
| 0x4006:002 | Load loss detection: Delay time | P710.02 | U16 | 0.0 s | general | Lenze | i550 | ||
| 0x4006:003 | Load loss detection: Error response | P710.03 | U8 | No response [0] | general | Lenze | i550 | ||
| 0x4007:001 | Heavy load monitoring: Error threshold | U16 | 200.0 % | general | Lenze | i550 | |||
| 0x4007:002 | Heavy load monitoring: Delay time | U16 | 3.0 s | general | Lenze | i550 | |||
| 0x4007:003 | Heavy load monitoring: Error response | U8 | No response [0] | general | Lenze | i550 | |||
| 0x4008:001 | Process input words: NetWordIN1 | P590.01 | U16 | 0x0000 | general | Lenze | i550 | ||
| 0x4008:002 | Process input words: NetWordIN2 | P590.02 | U16 | 0x0000 | general | Lenze | i550 | ||
| 0x4008:003 | Process input words: NetWordIN3 | P590.03 | U16 | 0.0 % | general | Lenze | i550 | ||
| 0x4008:004 | Process input words: NetWordIN4 | P590.04 | U16 | 0.0 % | general | Lenze | i550 | ||
| 0x4008:005 | Process input words: NetWordIN5 | P590.05 | I16 | 0.0 % | general | Lenze | i550 | ||
| 0x4009:001 | MOP values saved: Frequency | U16 | x.x Hz (Read only) | general | Lenze | i550 |