Title Parameter Display Code Data type Default setting Attributes Fieldbus Manufacturer Product category Operations
0x2D4D:006 Motor utilisation (i²xt) - specific characteristic: y3 = i03/iN (x3) U16 100 % - Lenze i950
0x2D4D:007 Motor utilisation (i²xt) - specific characteristic: x4 = n04/nN (n04 = limit field weakening) U16 100 % - Lenze i950
0x2D4D:008 Motor utilisation (i²xt) - specific characteristic: y4 = i04/iN (x4) U16 100 % - Lenze i950
0x2D4E Motor utilisation (i²xt) - warning threshold U16 100 % - Lenze i950
0x2D4F Motor utilisation (i²xt) U16 x % (Read only) - Lenze i950, i550
0x2D50:001 Motor utilisation (i²xt) - monitoring: Error response U8 Error > CiA402 [1] - Lenze i950
0x2D50:002 Motor utilisation (i²xt) - monitoring: Error threshold U16 105 % - Lenze i950
0x2D51:001 Position error/speed error - monitoring: Speed error - error threshold U32 50 rpm - Lenze i950
0x2D51:002 Position error/speed error - monitoring: Speed error - min. time for error U16 0 ms - Lenze i950
0x2D51:003 Position error/speed error - monitoring: Speed error - error response U8 No response [0] - Lenze i950
0x2D51:004 Position error/speed error - monitoring: Position error - error threshold U32 360 ° - Lenze i950
0x2D51:005 Position error/speed error - monitoring: Position error - min. time for error U16 0 ms - Lenze i950
0x2D51:006 Position error/speed error - monitoring: Position error - error response U8 No response [0] - Lenze i950
0x2D52:001 Monitoring settings: Hysteresis for speed setpoint reached U16 0.0 % general Lenze i550
0x2D66:001 Mains failure control: Enable function U8 Disabled [0] - Lenze i950, i550
0x2D66:002 Mains failure control: DC-bus activation level U8 75 % - Lenze i950, i550
0x2D66:003 Mains failure control: Gain V-controller P721.03 U16 0.01000 Hz/V general Lenze i550
0x2D66:004 Mains failure control: Reset time V-controller P721.04 U16 20 ms general Lenze i550
0x2D66:005 Mains failure control: DC voltage setpoint P721.05 U8 100 % general Lenze i550
0x2D66:006 Mains failure control: Setpoint ramp P721.06 U16 20 ms general Lenze i550
0x2D66:007 Mains failure control: Clear time P721.07 U16 20 ms general Lenze i550
0x2D66:008 Mains failure control: Restart threshold P721.08 U16 0.0 Hz general Lenze i550
0x2D66:009 Mains failure control: Status mains failure control P721.09 U8 - (Read only) general Lenze i550
0x2D66:011 Mains failure control: Filter time U16 0.00 s - Lenze i950
0x2D66:012 Mains failure control: Ramp max. torque U16 30.0 % - Lenze i950
0x2D66:013 Mains failure control: Ramp time U16 1.00 s - Lenze i950
0x2D66:014 Mains failure control: Actual DC bus voltage (filtered) U32 x.xxx V (Read only) - Lenze i950
0x2D67:001 Maximum torque monitoring: Response P329.01 U8 No response [0] MCTRL Lenze i550
0x2D67:002 Maximum torque monitoring: Triggering delay P329.02 U16 0.000 s MCTRL Lenze i550
0x2D81:001 Life-diagnosis: Operating time U32 x s (Read only) - Lenze i950, i550
0x2D81:002 Life-diagnosis: Power-on time U32 x s (Read only) - Lenze i950, i550
0x2D81:003 Life-diagnosis: Control unit operating time P151.03 U64 x ns (Read only) general Lenze i550
0x2D81:004 Life-diagnosis: Main switching cycles U32 - (Read only) - Lenze i950, i550
0x2D81:005 Life-diagnosis: Relay switching cycles P151.05 U32 - (Read only) general Lenze i550
0x2D81:006 Life-diagnosis: Short-circuit counter U32 - (Read only) - Lenze i950, i550
0x2D81:007 Life-diagnosis: Earth fault counter U32 - (Read only) - Lenze i950, i550
0x2D81:008 Life-diagnosis: Clamp active P151.08 U16 - (Read only) general Lenze i550
0x2D81:009 Life-diagnosis: Fan operating time U32 x s (Read only) - Lenze i950, i550
0x2D82 Motor actual voltage (Veff) U32 x.x V (Read only) - Lenze i950
0x2D83:001 Motor phase currents: Zero system current I32 x.xx A (Read only) - Lenze i950
0x2D83:002 Motor phase currents: Phase U current I32 x.xx A (Read only) - Lenze i950
0x2D83:003 Motor phase currents: Phase V current I32 x.xx A (Read only) - Lenze i950
0x2D83:004 Motor phase currents: Phase W current I32 x.xx A (Read only) - Lenze i950
0x2D84:001 Heatsink temperature: Heatsink temperature I16 x.x °C (Read only) - Lenze i950, i550
0x2D84:002 Heatsink temperature: Warning threshold I16 90.0 °C - Lenze i950, i550
0x2D87 DC-bus voltage P105.00 U16 x V (Read only) general Lenze i550
0x2D88 Motor current P104.00 I16 x.x A (Read only) general Lenze i550
0x2D89 Motor voltage P106.00 U16 x VAC (Read only) general Lenze i550
0x2D8A Actual speed error I32 x rpm (Read only) - Lenze i950
0x2DA2:001 Output power: Effective power I32 x.xxx kW (Read only) - Lenze i950, i550