0x2D02:001 Touch probe diagnostics: Touch probe 3/4 function U16 0x0000 H Lenze i950
0x2D02:002 Touch probe diagnostics: Touch-Probe 3/4 status U16 - (Read only) H Lenze i950
0x2D03:001 Touch probe position: Touch probe 3 position rising edge I32 - (Read only) - Lenze i950
0x2D03:002 Touch probe position: Touch probe 3 position falling edge I32 - (Read only) - Lenze i950
0x2D03:003 Touch probe position: Touch probe 4 position rising edge I32 - (Read only) - Lenze i950
0x2D03:004 Touch probe position: Touch probe 4 position falling edge I32 - (Read only) - Lenze i950
0x2D40:001 Device utilisation ixt: Power unit actual utilisation U16 x % (Read only) - Lenze i950
0x2D40:002 Device utilisation ixt: Power unit warning threshold U16 95 % - Lenze i950, i550
0x2D40:003 Device utilisation ixt: Power unit error threshold U16 x % (Read only) - Lenze i950
0x2D40:004 Device utilisation ixt: Device actual utilisation U16 x % (Read only) - Lenze i950, i550
0x2D40:005 Device utilisation ixt: Device warning threshold U16 95 % - Lenze i950, i550
0x2D40:006 Device utilisation ixt: Device error threshold U16 x % (Read only) - Lenze i950
0x2D40:007 Device utilisation ixt: Actual total utilisation U16 x % (Read only) - Lenze i950
0x2D40:008 Device utilisation ixt: Total utilisation warning threshold U16 95 % - Lenze i950
0x2D40:009 Device utilisation ixt: Total utilisation error threshold U16 x % (Read only) - Lenze i950
0x2D43:001 Inverter load characteristic: Duty selection P306.01 U8 Heavy Duty [0] general Lenze i550
0x2D44:001 Overspeed monitoring: Threshold U16 8000 rpm - Lenze i950, i550
0x2D44:002 Overspeed monitoring: Response U8 Fault > CiA402 [1] - Lenze i950, i550
0x2D45:001 Motor phase failure detection: Response - Motor phase 1 U8 No response [0] - Lenze i950, i550
0x2D45:002 Motor phase failure detection: Current threshold U8 5.0 % - Lenze i950, i550
0x2D45:003 Motor phase failure detection: Voltage threshold U16 10.0 V - Lenze i950, i550
0x2D45:004 Motor phase failure detection: Response - Motor phase 2 U8 No response [0] - Lenze i950
0x2D46:001 Overcurrent monitoring: Threshold U16 5.4 A - Lenze i950, i550
0x2D46:002 Overcurrent monitoring: Response U8 Fault > CiA402 [1] - Lenze i950, i550
0x2D48:002 PTC temperature sensor monitoring: Error response U8 Fault > CiA402 [1] - Lenze i950
0x2D49:001 Motor temperature monitoring: Temperature sensor type U8 PT1000 [5] - Lenze i950
0x2D49:002 Motor temperature monitoring: Response U8 Warning [1] - Lenze i950, i550
0x2D49:003 Motor temperature monitoring: Warning threshold I16 145.0 °C - Lenze i950
0x2D49:004 Motor temperature monitoring: Error threshold I16 155.0 °C - Lenze i950
0x2D49:005 Motor temperature monitoring: Actual motor temperature I16 x.x °C (Read only) - Lenze i950
0x2D49:006 Motor temperature monitoring: Spec. characteristic temperature grid point 1 I16 25.0 °C - Lenze i950
0x2D49:007 Motor temperature monitoring: Spec. characteristic temperature grid point 2 I16 150.0 °C - Lenze i950
0x2D49:008 Motor temperature monitoring: Spec. characteristic resistance grid point 1 I16 1000 Ω - Lenze i950
0x2D49:009 Motor temperature monitoring: Spec. characteristic resistance grid point 2 I16 2225 Ω - Lenze i950
0x2D49:010 Motor temperature monitoring: Temperature sensor feedback type U8 Motor encoder [0] - Lenze i950
0x2D49:011 Motor temperature monitoring: Motor temperature (Motor encoder) I16 x.x °C (Read only) - Lenze i950
0x2D49:012 Motor temperature monitoring: Motor temperature (load encoder) I16 x.x °C (Read only) - Lenze i950
0x2D4B:001 Motor overload monitoring (i²xt): Maximum utilisation [60 s] P308.01 U16 150 % MCTRL Lenze i550
0x2D4B:002 Motor overload monitoring (i²xt): Speed compensation P308.02 U8 On [0] MCTRL Lenze i550
0x2D4B:003 Motor overload monitoring (i²xt): Response P308.03 U8 Fault [3] general Lenze i550
0x2D4B:005 Motor overload monitoring (i²xt): Thermal load U16 - (Read only) general Lenze i550
0x2D4C:001 Thermal model motor utilization (i²xt): Motor utilisation (i²xt) U16 60 s - Lenze i950
0x2D4C:002 Thermal model motor utilization (i²xt): Thermal time constant - laminations U16 852 s - Lenze i950
0x2D4C:003 Thermal model motor utilization (i²xt): Winding influence U8 27 % - Lenze i950
0x2D4C:004 Thermal model motor utilization (i²xt): Starting value U16 0 % - Lenze i950
0x2D4D:001 Motor utilisation (i²xt) - specific characteristic: x1 = n01/nN (n01 ~ 0) U16 0 % - Lenze i950
0x2D4D:002 Motor utilisation (i²xt) - specific characteristic: y1 = i01/iN (x1) U16 100 % - Lenze i950
0x2D4D:003 Motor utilisation (i²xt) - specific characteristic: x2 = n02/nN (n02 = limit reduced cooling) U16 0 % - Lenze i950
0x2D4D:004 Motor utilisation (i²xt) - specific characteristic: y2 = i02/iN (x2) U16 100 % - Lenze i950
0x2D4D:005 Motor utilisation (i²xt) - specific characteristic: x3 = n03/nN (n03 = rated speed) U16 100 % - Lenze i950