0x2C5A:022 Load encoder/master encoder (SSI) protocol parameters: Monoflop time U16 0 C Lenze i950
0x2C5A:023 Load encoder/master encoder (SSI) protocol parameters: Resulting SSI-telegram cycle time U16 - (Read only) - Lenze i950
0x2C5F Parameter CRC of load encoder/master encoder U32 - (Read only) - Lenze i950
0x2C60 PPI monitoring: Response U8 Fault > CiA402 [1] - Lenze i950, i550
0x2C61:001 Pole position identification (360°) settings: Current amplitude U16 71 % C Lenze i950
0x2C61:002 Pole position identification (360°) settings: Ramp time U16 40 s C Lenze i950
0x2C61:003 Pole position identification (360°) settings: Direction of rotation U8 CW [0] C Lenze i950
0x2C61:004 Pole position identification (360°) settings: Error tolerance U8 20 ° - Lenze i950
0x2C61:005 Pole position identification (360°) settings: Absolute current amplitude U32 x.xx A (Read only) - Lenze i950
0x2C61:006 Pole position identification (360°) settings: ixt threshold for reversal of rotating direction U8 30 % - Lenze i950
0x2C61:010 Pole position identification (360°) settings: Actual commutation angle U32 x.xxx ° (Read only) - Lenze i950
0x2C62:001 Pole position identification (min. movement) settings: Current amplitude U16 25 % C Lenze i950
0x2C62:002 Pole position identification (min. movement) settings: Ramp time U16 10 s C Lenze i950
0x2C62:003 Pole position identification (min. movement) settings: Gain U16 0 % - Lenze i950
0x2C62:004 Pole position identification (min. movement) settings: Reset time U16 62.5 ms - Lenze i950
0x2C62:005 Pole position identification (min. movement) settings: Max. move permitted U8 20 ° - Lenze i950
0x2C62:006 Pole position identification (min. movement) settings: Absolute current amplitude U32 x.xx A (Read only) - Lenze i950
0x2C63:001 PPI without movement: Execution U8 Disabled [0] C Lenze i950, i550
0x2C63:002 PPI without movement: Current adjust factor U16 100 % C Lenze i950, i550
0x2C64:001 Cable Check: Behavior after switch on U8 No action [0] C Lenze i950
0x2C64:002 Cable Check: Status word U16 - (Read only) H Lenze i950
0x2C65:001 PPI validation: Activation U8 Off [0] C Lenze i950
0x2C65:002 PPI validation: Settings U8 No action [0] - Lenze i950
0x2C65:003 PPI validation: Status U16 - (Read only) H Lenze i950
0x2C65:004 PPI validation: Pole position set value I16 0.0 ° - Lenze i950
0x2C66:001 PPI mode for 0x6060: Selection U8 PPI 360° [1] C Lenze i950
0x2C67:001 MOL settings for 0x6060: Current setpoint 1 U16 71 % - Lenze i950
0x2C67:002 MOL settings for 0x6060: Frequency 1 I16 1.0 Hz - Lenze i950
0x2C67:003 MOL settings for 0x6060: Current 1 - ramp time U16 10 ms - Lenze i950
0x2C67:004 MOL settings for 0x6060: Frequency 1 - ramp time U16 200 ms - Lenze i950
0x2C67:005 MOL settings for 0x6060: Starting angle 1 I16 0.0 ° - Lenze i950
0x2C67:006 MOL settings for 0x6060: Stopping time 1 U32 10000.0 s C Lenze i950
0x2C67:011 MOL settings for 0x6060: Current setpoint 2 U16 71 % - Lenze i950
0x2C67:012 MOL settings for 0x6060: Frequency 2 I16 5.0 Hz - Lenze i950
0x2C67:013 MOL settings for 0x6060: Current 2 - ramp time U16 10 ms - Lenze i950
0x2C67:014 MOL settings for 0x6060: Frequency 2 - ramp time U16 1000 ms - Lenze i950
0x2C67:015 MOL settings for 0x6060: Starting angle 2 I16 0.0 ° - Lenze i950
0x2C67:016 MOL settings for 0x6060: Stopping time 2 U32 10000.0 s C Lenze i950
0x2D00:001 Touch probe (TP) delay time: Touch probe 1 delay time U16 0.000 ms - Lenze i950
0x2D00:002 Touch probe (TP) delay time: Touch probe 2 delay time U16 0.000 ms - Lenze i950
0x2D00:003 Touch probe (TP) delay time: Touch probe 3 delay time U16 0.000 ms - Lenze i950
0x2D00:004 Touch probe (TP) delay time: Touch probe 4 delay time U16 0.000 ms - Lenze i950
0x2D01:001 Touch probe (TP) time stamp: Touch probe 1-rising edge time stamp U32 x ns (Read only) - Lenze i950
0x2D01:002 Touch probe (TP) time stamp: Touch probe 1-falling edge time stamp U32 x ns (Read only) - Lenze i950
0x2D01:003 Touch probe (TP) time stamp: Touch probe 2-rising edge time stamp U32 x ns (Read only) - Lenze i950
0x2D01:004 Touch probe (TP) time stamp: Touch probe 2-falling edge time stamp U32 x ns (Read only) - Lenze i950
0x2D01:005 Touch probe (TP) time stamp: Touch probe 3-rising edge time stamp U32 x ns (Read only) - Lenze i950
0x2D01:006 Touch probe (TP) time stamp: Touch probe 3-falling edge time stamp U32 x ns (Read only) - Lenze i950
0x2D01:007 Touch probe (TP) time stamp: Touch probe 4-rising edge time stamp U32 x ns (Read only) - Lenze i950
0x2D01:008 Touch probe (TP) time stamp: Touch probe 4-falling edge time stamp U32 x ns (Read only) - Lenze i950