0x2C11:004 High speed range: Tracking controller decouple time U16 200.0 ms MCTRL Lenze i550
0x2C11:006 High speed range: Stall monitoring limit U16 50 % MCTRL Lenze i550
0x2C12:001 SM low speed range: Acceleration current U16 70 % MCTRL Lenze i550
0x2C12:002 SM low speed range: Standstill current U16 30 % MCTRL Lenze i550
0x2C13 SLSM-PSM low speed method U8 Carrier based [1] MCTRL Lenze i550
0x2C16:001 Cogging torque compensation: Enable compensation U8 On [1] - Lenze i950
0x2C16:002 Cogging torque compensation: Commutation turns U8 1 - Lenze i950
0x2C16:003 Cogging torque compensation: Max. recommended identification speed U16 x rpm (Read only) - Lenze i950
0x2C16:004 Cogging torque compensation: Max. compensation speed U8 [13] - Lenze i950
0x2C16:005 Cogging torque compensation: Identification state U16 - (Read only) H Lenze i950
0x2C16:006 Cogging torque compensation: Amplitude 1 I16 0.000 % C Lenze i950
0x2C16:007 Cogging torque compensation: Phase 1 I16 0.0 ° C Lenze i950
0x2C16:008 Cogging torque compensation: Amplitude 2 I16 0.000 % C Lenze i950
0x2C16:009 Cogging torque compensation: Phase 2 I16 0.0 ° C Lenze i950
0x2C16:010 Cogging torque compensation: Amplitude 3 I16 0.000 % C Lenze i950
0x2C16:011 Cogging torque compensation: Phase 3 I16 0.0 ° C Lenze i950
0x2C16:012 Cogging torque compensation: Amplitude 4 I16 0.000 % C Lenze i950
0x2C16:013 Cogging torque compensation: Phase 4 I16 0.0 ° C Lenze i950
0x2C16:014 Cogging torque compensation: Amplitude 5 I16 0.000 % C Lenze i950
0x2C16:015 Cogging torque compensation: Phase 5 I16 0.0 ° C Lenze i950
0x2C16:016 Cogging torque compensation: Amplitude 6 I16 0.000 % C Lenze i950
0x2C16:017 Cogging torque compensation: Phase 6 I16 0.0 ° C Lenze i950
0x2C16:018 Cogging torque compensation: Amplitude 7 I16 0.000 % C Lenze i950
0x2C16:019 Cogging torque compensation: Phase 7 I16 0.0 ° C Lenze i950
0x2C16:020 Cogging torque compensation: Amplitude 8 I16 0.000 % C Lenze i950
0x2C16:021 Cogging torque compensation: Phase 8 I16 0.0 ° C Lenze i950
0x2C16:022 Cogging torque compensation: Amplitude 9 I16 0.000 % C Lenze i950
0x2C16:023 Cogging torque compensation: Phase 9 I16 0.0 ° C Lenze i950
0x2C16:024 Cogging torque compensation: Amplitude 10 I16 0.000 % C Lenze i950
0x2C16:025 Cogging torque compensation: Phase 10 I16 0.0 ° C Lenze i950
0x2C40 Motor encoder type U8 SinCos encoder [1] C Lenze i950
0x2C41:001 Motor encoder settings (HIPERFACE®): Type code detected U8 - (Read only) - Lenze i950
0x2C41:002 Motor encoder settings (HIPERFACE®): Type code manual input U8 0 C Lenze i950
0x2C41:003 Motor encoder settings (HIPERFACE®): Manual input - Number of detectable motor encoder revolutions U16 1 C Lenze i950
0x2C41:004 Motor encoder settings (HIPERFACE®): Error response U8 Fault > CiA402 [1] - Lenze i950
0x2C41:005 Motor encoder settings (HIPERFACE®): Serial number STRING[50] - (Read only) - Lenze i950
0x2C41:006 Motor encoder settings (HIPERFACE®): Actual position (raw data) U32 - (Read only) - Lenze i950
0x2C41:007 Motor encoder settings (HIPERFACE®): No. of periods detected U16 - (Read only) - Lenze i950
0x2C41:008 Motor encoder settings (HIPERFACE®): Type code verification U8 - (Read only) - Lenze i950
0x2C41:009 Motor encoder settings (HIPERFACE®): Encoder type U8 - (Read only) - Lenze i950
0x2C41:010 Motor encoder settings (HIPERFACE®): Period length of linear encoder U32 x nm (Read only) - Lenze i950
0x2C42:001 Encoder settings: Increments/revolution U32 1024 C Lenze i950, i550
0x2C42:002 Encoder settings: Supply voltage U8 5.0 V C Lenze i950
0x2C42:003 Encoder settings: Angle drift I16 x.x ° (Read only) - Lenze i950
0x2C42:004 Encoder settings: Actual amplitude signal quality U8 x % (Read only) - Lenze i950
0x2C42:006 Encoder settings: Actual velocity I32 x rpm (Read only) general Lenze i550
0x2C42:007 Encoder settings: Status U32 - (Read only) general Lenze i550
0x2C42:008 Encoder settings: Encoder voltage cos track I16 x.xxx V (Read only) - Lenze i950
0x2C42:009 Encoder settings: Encoder voltage sin track I16 x.xxx V (Read only) - Lenze i950
0x2C42:010 Encoder settings: TTL/HTL signal evaluation U8 High resolution encoder - 4-fold evaluation [1] C Lenze i950