0x2C04:019 d-axis Lss saturation characteristic: Cross saturation factor U16 0 % - Lenze i950
0x2C05 Reference for current grid points (x) Lss saturation characteristic U16 5.4 A - Lenze i950
0x2C06:001 Grid points for magnet characteristic (current): x1 = i01/iN U16 0 % - Lenze i950
0x2C06:002 Grid points for magnet characteristic (current): y1 = kT01/kTN U16 100 % - Lenze i950
0x2C06:003 Grid points for magnet characteristic (current): x2 = i02/iN U16 100 % - Lenze i950
0x2C06:004 Grid points for magnet characteristic (current): y2 = kT02/kTN U16 100 % - Lenze i950
0x2C06:005 Grid points for magnet characteristic (current): x3 = i03/iN U16 200 % - Lenze i950
0x2C06:006 Grid points for magnet characteristic (current): y3 = kT03/kTN U16 100 % - Lenze i950
0x2C06:007 Grid points for magnet characteristic (current): x4 = i04/iN U16 415 % - Lenze i950
0x2C06:008 Grid points for magnet characteristic (current): y4 = kT04/kTN U16 72 % - Lenze i950
0x2C07:001 Inductance grid points (y) Lh saturation characteristic: y1 = L01 (x = 0.00 %) U16 118 % - Lenze i950
0x2C07:002 Inductance grid points (y) Lh saturation characteristic: y2 = L02 (x = 6.25 %) U16 118 % - Lenze i950
0x2C07:003 Inductance grid points (y) Lh saturation characteristic: y3 = L03 (x = 12.50 %) U16 118 % - Lenze i950
0x2C07:004 Inductance grid points (y) Lh saturation characteristic: y4 = L04 (x = 18.75 %) U16 117 % - Lenze i950
0x2C07:005 Inductance grid points (y) Lh saturation characteristic: y5 = L05 (x = 25.00 %) U16 116 % - Lenze i950
0x2C07:006 Inductance grid points (y) Lh saturation characteristic: y6 = L06 (x = 31.25 %) U16 114 % - Lenze i950
0x2C07:007 Inductance grid points (y) Lh saturation characteristic: y7 = L07 (x = 37.50 %) U16 111 % - Lenze i950
0x2C07:008 Inductance grid points (y) Lh saturation characteristic: y8 = L08 (x = 43.75 %) U16 107 % - Lenze i950
0x2C07:009 Inductance grid points (y) Lh saturation characteristic: y9 = L09 (x = 50.00 %) U16 100 % - Lenze i950
0x2C07:010 Inductance grid points (y) Lh saturation characteristic: y10 = L10 (x = 56.25 %) U16 93 % - Lenze i950
0x2C07:011 Inductance grid points (y) Lh saturation characteristic: y11 = L11 (x = 62.50 %) U16 86 % - Lenze i950
0x2C07:012 Inductance grid points (y) Lh saturation characteristic: y12 = L12 (x = 68.75 %) U16 78 % - Lenze i950
0x2C07:013 Inductance grid points (y) Lh saturation characteristic: y13 = L13 (x = 75.00 %) U16 71 % - Lenze i950
0x2C07:014 Inductance grid points (y) Lh saturation characteristic: y14 = L14 (x = 81.25 %) U16 64 % - Lenze i950
0x2C07:015 Inductance grid points (y) Lh saturation characteristic: y15 = L15 (x = 87.50 %) U16 57 % - Lenze i950
0x2C07:016 Inductance grid points (y) Lh saturation characteristic: y16 = L16 (x = 93.75 %) U16 50 % - Lenze i950
0x2C07:017 Inductance grid points (y) Lh saturation characteristic: y17 = L17 (x = 100.00 %) U16 42 % - Lenze i950
0x2C08 Method for setting motor parameters U8 Select from catalogue (Lenze motors) [1] - Lenze i950
0x2C09:001 q-axis Lss saturation characteristic: y1 = L01 (x = 0.00 %) U16 165 % - Lenze i950
0x2C09:003 q-axis Lss saturation characteristic: y3 = L03 (x = 12.50 %) U16 146 % - Lenze i950
0x2C09:004 q-axis Lss saturation characteristic: y4 = L04 (x = 18.75 %) U16 117 % - Lenze i950
0x2C09:005 q-axis Lss saturation characteristic: y5 = L05 (x = 25.00 %) U16 97 % - Lenze i950
0x2C09:006 q-axis Lss saturation characteristic: y6 = L06 (x = 31.25 %) U16 82 % - Lenze i950
0x2C09:007 q-axis Lss saturation characteristic: y7 = L07 (x = 37.50 %) U16 71 % - Lenze i950
0x2C09:008 q-axis Lss saturation characteristic: y8 = L08 (x = 42.75 %) U16 62 % - Lenze i950
0x2C09:009 q-axis Lss saturation characteristic: y9 = L09 (x = 50.00 %) U16 55 % - Lenze i950
0x2C09:010 q-axis Lss saturation characteristic: y10 = L10 (x = 56.25 %) U16 50 % - Lenze i950
0x2C09:011 q-axis Lss saturation characteristic: y11 = L11 (x = 62.50 %) U16 46 % - Lenze i950
0x2C09:012 q-axis Lss saturation characteristic: y12 = L12 (x = 68.75 %) U16 43 % - Lenze i950
0x2C09:013 q-axis Lss saturation characteristic: y13 = L13 (x = 75.00 %) U16 42 % - Lenze i950
0x2C09:014 q-axis Lss saturation characteristic: y14 = L14 (x = 81.25 %) U16 41 % - Lenze i950
0x2C09:015 q-axis Lss saturation characteristic: y15 = L15 (x = 87.50 %) U16 41 % - Lenze i950
0x2C09:016 q-axis Lss saturation characteristic: y16 = L16 (x = 93.25 %) U16 41 % - Lenze i950
0x2C09:017 q-axis Lss saturation characteristic: y17 = L17 (x = 100.00 %) U16 41 % - Lenze i950
0x2C09:018 q-axis Lss saturation characteristic: Table source U16 Identical to d-axis (0x2C04) [0] - Lenze i950
0x2C10:001 HF amplitude U16 50.0 V MCTRL Lenze i550
0x2C10:008 HF injection range U16 6.0 % MCTRL Lenze i550
0x2C11:001 High speed range: Lower limit U16 10 % MCTRL Lenze i550
0x2C11:002 High speed range: Tracking controller gain U16 200 % MCTRL Lenze i550
0x2C11:003 High speed range: Tracking controller reset time U16 6.00 ms MCTRL Lenze i550