0x2BA1 Flying restart circuit U16 15 % - Lenze i950
0x2BA1:001 Flying restart circuit: Current P718.01 U16 30 % MCTRL Lenze i550
0x2BA1:002 Flying restart circuit: Start frequency P718.02 I16 20.0 Hz MCTRL Lenze i550
0x2BA1:003 Flying restart circuit: Restart time P718.03 U16 5911 ms * MCTRL Lenze i550
0x2BA1:008 Flying restart circuit: Flying restart frequency P718.08 I16 x.x Hz (Read only) MCTRL Lenze i550
0x2BA2 Start frequency I16 20.0 Hz - Lenze i950
0x2BA3 Integration time U16 600 ms - Lenze i950
0x2BA4 Minimum deviation U16 5.00 ° - Lenze i950
0x2BA5 Delay time U16 0 ms - Lenze i950
0x2BA6:001 Result: Determined speed [rpm] I16 x rpm (Read only) - Lenze i950
0x2BA6:002 Result: Determined speed [n unit] I32 rpm (Read only) - Lenze i950
0x2C00 Motor control mode U8 Servo control (SC-PSM) [1] C Lenze i950, i550
0x2C01:001 Motor parameters: Number of pole pairs U8 - (Read only) - Lenze i950, i550
0x2C01:002 Motor parameters: Stator resistance U32 13.5000 Ω - Lenze i950, i550
0x2C01:003 Motor parameters: Stator leakage inductance U32 51.000 mH - Lenze i950, i550
0x2C01:004 Motor parameters: Rated speed U16 4050 rpm - Lenze i950, i550
0x2C01:005 Motor parameters: Rated frequency U16 270.0 Hz - Lenze i950, i550
0x2C01:006 Motor parameters: Rated power U16 0.25 kW - Lenze i950, i550
0x2C01:007 Motor parameters: Rated voltage U16 225 V - Lenze i950, i550
0x2C01:008 Motor parameters: Cosine phi U16 0.80 - Lenze i950, i550
0x2C01:009 Motor parameters: Insulation class U8 F (cut-off temperature = 155 °C) [4] - Lenze i950
0x2C01:010 Motor parameters: Motor name STRING[50] "MCS06C41" - Lenze i950, i550
0x2C02:001 Motor parameter (ASM): Rotor resistance U32 0.0000 Ω - Lenze i950, i550
0x2C02:002 Motor parameter (ASM): Mutual inductance U32 0.0 mH - Lenze i950, i550
0x2C02:003 Motor parameter (ASM): Magnetising current U16 0.00 A - Lenze i950, i550
0x2C02:004 Motor parameter (ASM): Slip frequency P351.04 U16 x.x Hz (Read only) MCTRL Lenze i550
0x2C03:001 Motor parameter (PSM): Back EMF constant U32 41.8 V/1000rpm - Lenze i950, i550
0x2C03:002 Motor parameter (PSM): Resolver pole position I16 -90.0 ° - Lenze i950
0x2C03:003 Motor parameter (PSM): Magnets temperature coefficient (kTN) I16 -0.110 %/°C - Lenze i950
0x2C03:004 Motor parameter (PSM): Encoder pole position I16 0.0 ° - Lenze i950
0x2C03:005 Motor parameter (PSM): D-axis inductance Ld P352.05 U32 20.000 mH * MCTRL Lenze i550
0x2C03:006 Motor parameter (PSM): Q-axis inductance Lq P352.06 U32 20.000 mH * MCTRL Lenze i550
0x2C04:001 d-axis Lss saturation characteristic: y1 = L01 (x = 0.00 %) U16 165 % - Lenze i950
0x2C04:002 d-axis Lss saturation characteristic: y2 = L02 (x = 6.25 %) U16 200 % - Lenze i950
0x2C04:003 d-axis Lss saturation characteristic: y3 = L03 (x = 12.50 %) U16 146 % - Lenze i950
0x2C04:004 d-axis Lss saturation characteristic: y4 = L04 (x = 18.75 %) U16 117 % - Lenze i950
0x2C04:005 d-axis Lss saturation characteristic: y5 = L05 (x = 25.00 %) U16 97 % - Lenze i950
0x2C04:006 d-axis Lss saturation characteristic: y6 = L06 (x = 31.25 %) U16 82 % - Lenze i950
0x2C04:007 d-axis Lss saturation characteristic: y7 = L07 (x = 37.50 %) U16 71 % - Lenze i950
0x2C04:008 d-axis Lss saturation characteristic: y8 = L08 (x = 42.75 %) U16 62 % - Lenze i950
0x2C04:009 d-axis Lss saturation characteristic: y9 = L09 (x = 50.00 %) U16 55 % - Lenze i950
0x2C04:010 d-axis Lss saturation characteristic: y10 = L10 (x = 56.25 %) U16 50 % - Lenze i950
0x2C04:011 d-axis Lss saturation characteristic: y11 = L11 (x = 62.50 %) U16 46 % - Lenze i950
0x2C04:012 d-axis Lss saturation characteristic: y12 = L12 (x = 68.75 %) U16 43 % - Lenze i950
0x2C04:013 d-axis Lss saturation characteristic: y13 = L13 (x = 75.00 %) U16 42 % - Lenze i950
0x2C04:014 d-axis Lss saturation characteristic: y14 = L14 (x = 81.25 %) U16 41 % - Lenze i950
0x2C04:015 d-axis Lss saturation characteristic: y15 = L15 (x = 87.50 %) U16 41 % - Lenze i950
0x2C04:016 d-axis Lss saturation characteristic: y16 = L16 (x = 93.25 %) U16 41 % - Lenze i950
0x2C04:017 d-axis Lss saturation characteristic: y17 = L17 (x = 100.00 %) U16 41 % - Lenze i950
0x2C04:018 d-axis Lss saturation characteristic: Activation Lss saturation characteristic U16 Adjustment on [1] - Lenze i950