Title Parameter Display Code Data type Default setting Attributes Fieldbus Manufacturer Product category Operations
0x2B03:005 Voltage grid points (y) user V/f characteristic: y5 = U05 (x = f05) U32 80.00 V - Lenze i950, i550
0x2B03:006 Voltage grid points (y) user V/f characteristic: y6 = U06 (x = f06) U32 0.00 V - Lenze i950, i550
0x2B03:007 Voltage grid points (y) user V/f characteristic: y7 = U07 (x = f07) U32 80.00 V - Lenze i950, i550
0x2B03:008 Voltage grid points (y) user V/f characteristic: y8 = U08 (x = f08) U32 160.00 V - Lenze i950, i550
0x2B03:009 Voltage grid points (y) user V/f characteristic: y9 = U09 (x = f09) U32 240.00 V - Lenze i950, i550
0x2B03:010 Voltage grid points (y) user V/f characteristic: y10 = U10 (x = f10) U32 320.00 V - Lenze i950, i550
0x2B03:011 Voltage grid points (y) user V/f characteristic: y11 = U11 (x = f11) U32 400.00 V - Lenze i950, i550
0x2B04 V/f boost controller - current setpoint U32 0.00 A - Lenze i950
0x2B05:001 V/f boost controller settings: Gain U32 148.21 V/A - Lenze i950
0x2B05:002 V/f boost controller settings: Reset time U32 3.77 ms - Lenze i950
0x2B05:003 V/f boost controller settings: Dynamic current setpoint U32 0.00 A - Lenze i950
0x2B06 Voltage boost U16 0.0 V - Lenze i950
0x2B07:001 Load adaption: Direction of rotation U8 Passive load [0] C Lenze i950
0x2B07:002 Load adaption: Load adaption value U32 20.00 % - Lenze i950
0x2B08:001 V/f Imax controller: Gain U32 0.001 Hz/A - Lenze i950, i550
0x2B08:002 V/f Imax controller: Reset time U32 100.0 ms - Lenze i950, i550
0x2B09:001 Slip compensation: Gain I16 0.00 % - Lenze i950, i550
0x2B09:002 Slip compensation: Filter time U16 2000 ms - Lenze i950, i550
0x2B0A:001 Oscillation damping: Gain I16 20 % - Lenze i950, i550
0x2B0A:002 Oscillation damping: Filter time U16 5 ms - Lenze i950, i550
0x2B0A:003 Oscillation damping: Limitation U16 0.2 Hz - Lenze i950
0x2B0A:004 Oscillation damping: Final ramp frequency U8 0 % - Lenze i950
0x2B0B Ramp generator frequency I16 x.x Hz (Read only) - Lenze i950, i550
0x2B0C Override field weakening I16 0.0 Hz - Lenze i950, i550
0x2B0D:001 VFC-ECO: Minimum voltage P330.01 I16 20 % MCTRL Lenze i550
0x2B0D:006 VFC-ECO: Cos phi actual value P330.06 I16 - (Read only) MCTRL Lenze i550
0x2B0E Frequency setpoint P102.00 I16 x.x Hz (Read only) general Lenze i550
0x2B0F Output frequency motor I16 x.x Hz (Read only) MCTRL Lenze i550
0x2B10:001 V/f torque limitation: Gain U16 0.00 % MCTRL Lenze i550
0x2B12:001 V/f voltage boost: Fixed boost P316.01 U8 2.5 % * MCTRL Lenze i550
0x2B12:002 V/f voltage boost: Boost at acceleration P316.02 U8 0.0 % general Lenze i550
0x2B13:001 Additive voltage impression: Enable Function U8 Disable [0] general Lenze i550
0x2B13:002 Additive voltage impression: Setpoint source U8 Analog input 1 [1] general Lenze i550
0x2B13:003 Additive voltage impression: Actual voltage I16 x V (Read only) general Lenze i550
0x2B13:004 Additive voltage impression: Ramp time U16 0.0 s general Lenze i550
0x2B14:001 Gain U16 0.100 - Lenze i950, i550
0x2B14:002 Reset time U16 100.0 ms - Lenze i950, i550
0x2B14:003 Frequency limitation U16 10.00 Hz - Lenze i950, i550
0x2B40:001 Gain U32 0.2686 Hz/A * MCTRL Lenze i550
0x2B40:002 Reset time U32 2.3 ms * MCTRL Lenze i550
0x2B40:003 Q-Feedforward U32 0.00 MCTRL Lenze i550
0x2B40:004 D-Feedforward U32 0.00 MCTRL Lenze i550
0x2B80 Current for DC-injection braking U16 0.00 A - Lenze i950
0x2B84:001 DC braking: Current P704.01 U16 0.0 % MCTRL Lenze i550
0x2B84:002 DC braking: Automatic hold time P704.02 U16 0.0 s general Lenze i550
0x2B84:003 DC braking: Automatic operating threshold P704.03 U16 0.0 Hz general Lenze i550
0x2B84:004 DC braking: Demagnetization time P704.04 U8 100 % general Lenze i550
0x2B84:005 DC braking: Default demagnetization time P704.05 U16 x ms (Read only) general Lenze i550
0x2B84:006 DC braking: Inverter disable P704.06 U8 Disabled [0] general Lenze i550
0x2BA0 Activate flying restart U8 Off [0] - Lenze i950