Title Parameter Display Code Data type Default setting Attributes Fieldbus Manufacturer Product category Operations
0x2947:012 Inverter characteristic: Value y12 U16 0.00 V - Lenze i950
0x2947:013 Inverter characteristic: Value y13 U16 0.00 V - Lenze i950
0x2947:014 Inverter characteristic: Value y14 U16 0.00 V - Lenze i950
0x2947:015 Inverter characteristic: Value y15 U16 0.00 V - Lenze i950
0x2947:016 Inverter characteristic: Value y16 U16 0.00 V - Lenze i950
0x2947:017 Inverter characteristic: Value y17 U16 0.00 V - Lenze i950
0x2948:001 Torque setpoint: Actual torque setpoint I16 x.x % (Read only) general Lenze i550
0x2948:002 Torque setpoint: ramp time P336.02 U16 1.0 s general Lenze i550
0x2949:001 Torque limit source selection: Positive torque limit source P337.01 U8 Max torque [0] general Lenze i550
0x2949:002 Torque limit source selection: Negative torque limit source P337.02 U8 (-) Max torque [0] general Lenze i550
0x2949:003 Torque limit source selection: Actual positive torque limit P337.03 I16 x.x % (Read only) general Lenze i550
0x2949:004 Torque limit source selection: Actual negative torque limit P337.04 I16 x.x % (Read only) general Lenze i550
0x294A:001 Torque limits offset: Torque offset I16 0.0 % - Lenze i950
0x294A:002 Torque limits offset: Resulting positive torque limit I16 x.x % (Read only) - Lenze i950
0x294A:003 Torque limits offset: Resulting negative torque limit I16 x.x % (Read only) - Lenze i950
0x2980 Position controller gain U32 28.40 1/s - Lenze i950
0x2981 Position controller gain adaption U16 100.00 % - Lenze i950
0x2982 Position controller output signal limitation U32 480000.00 rpm - Lenze i950
0x2983 Actual position start value I32 0 - Lenze i950
0x2984 Mode for setting the actual position U8 Absolute [0] - Lenze i950
0x2986 Resulting gain adaption U32 x.xx % (Read only) - Lenze i950
0x29C0:001 Field controller settings: Gain U32 165.84 A/Vs - Lenze i950, i550
0x29C0:002 Field controller settings: Reset time U16 15.1 ms - Lenze i950, i550
0x29E0:001 Field weakening controller settings: Gain (ASM) U32 0.000 Vs/V - Lenze i950, i550
0x29E0:002 Field weakening controller settings: Reset time (ASM) U32 2000.0 ms - Lenze i950, i550
0x29E0:003 Field weakening controller settings: Reset time (PSM) U32 800.0 ms * MCTRL Lenze i550
0x29E1 Field weakening controller Field limitation U16 100.00 % - Lenze i950, i550
0x29E2 DC-bus filter time U16 25.0 ms - Lenze i950, i550
0x29E3 Motor voltage filter time U16 25.0 ms - Lenze i950, i550
0x29E4 Voltage reserve range U8 5 % - Lenze i950, i550
0x2B00 V/f characteristic shape U8 Linear [0] C Lenze i950, i550
0x2B01:001 V/f shape data: Base voltage U16 225 V - Lenze i950, i550
0x2B01:002 V/f shape data: Base frequency U16 270 Hz - Lenze i950, i550
0x2B01:003 V/f shape data: Midpoint voltage P303.03 U16 0 V MCTRL Lenze i550
0x2B01:004 V/f shape data: Midpoint frequency P303.04 U16 0 Hz MCTRL Lenze i550
0x2B02:001 Frequency grid points (x) user V/f characteristic: x1 = f01 I16 -50 Hz - Lenze i950, i550
0x2B02:002 Frequency grid points (x) user V/f characteristic: x2 = f02 I16 -40 Hz - Lenze i950, i550
0x2B02:003 Frequency grid points (x) user V/f characteristic: x3 = f03 I16 -30 Hz - Lenze i950, i550
0x2B02:004 Frequency grid points (x) user V/f characteristic: x4 = f04 I16 -20 Hz - Lenze i950, i550
0x2B02:005 Frequency grid points (x) user V/f characteristic: x5 = f05 I16 -10 Hz - Lenze i950, i550
0x2B02:006 Frequency grid points (x) user V/f characteristic: x6 = f06 I16 0 Hz - Lenze i950, i550
0x2B02:007 Frequency grid points (x) user V/f characteristic: x7 = f07 I16 10 Hz - Lenze i950, i550
0x2B02:008 Frequency grid points (x) user V/f characteristic: x8 = f08 I16 20 Hz - Lenze i950, i550
0x2B02:009 Frequency grid points (x) user V/f characteristic: x9 = f09 I16 30 Hz - Lenze i950, i550
0x2B02:010 Frequency grid points (x) user V/f characteristic: x10 = f10 I16 40 Hz - Lenze i950, i550
0x2B02:011 Frequency grid points (x) user V/f characteristic: x11 = f11 I16 50 Hz - Lenze i950, i550
0x2B03:001 Voltage grid points (y) user V/f characteristic: y1 = U01 (x = f01) U32 400.00 V - Lenze i950, i550
0x2B03:002 Voltage grid points (y) user V/f characteristic: y2 = U02 (x = f02) U32 320.00 V - Lenze i950, i550
0x2B03:003 Voltage grid points (y) user V/f characteristic: y3 = U03 (x = f03) U32 240.00 V - Lenze i950, i550
0x2B03:004 Voltage grid points (y) user V/f characteristic: y4 = U04 (x = f04) U32 160.00 V - Lenze i950, i550