Parameters
Filters
| Title | Parameter | Display Code | Data type | Default setting | Attributes | Fieldbus | Manufacturer | Product category | Operations |
|---|---|---|---|---|---|---|---|---|---|
| 0x2947:012 | Inverter characteristic: Value y12 | U16 | 0.00 V | - | Lenze | i950 | |||
| 0x2947:013 | Inverter characteristic: Value y13 | U16 | 0.00 V | - | Lenze | i950 | |||
| 0x2947:014 | Inverter characteristic: Value y14 | U16 | 0.00 V | - | Lenze | i950 | |||
| 0x2947:015 | Inverter characteristic: Value y15 | U16 | 0.00 V | - | Lenze | i950 | |||
| 0x2947:016 | Inverter characteristic: Value y16 | U16 | 0.00 V | - | Lenze | i950 | |||
| 0x2947:017 | Inverter characteristic: Value y17 | U16 | 0.00 V | - | Lenze | i950 | |||
| 0x2948:001 | Torque setpoint: Actual torque setpoint | I16 | x.x % (Read only) | general | Lenze | i550 | |||
| 0x2948:002 | Torque setpoint: ramp time | P336.02 | U16 | 1.0 s | general | Lenze | i550 | ||
| 0x2949:001 | Torque limit source selection: Positive torque limit source | P337.01 | U8 | Max torque [0] | general | Lenze | i550 | ||
| 0x2949:002 | Torque limit source selection: Negative torque limit source | P337.02 | U8 | (-) Max torque [0] | general | Lenze | i550 | ||
| 0x2949:003 | Torque limit source selection: Actual positive torque limit | P337.03 | I16 | x.x % (Read only) | general | Lenze | i550 | ||
| 0x2949:004 | Torque limit source selection: Actual negative torque limit | P337.04 | I16 | x.x % (Read only) | general | Lenze | i550 | ||
| 0x294A:001 | Torque limits offset: Torque offset | I16 | 0.0 % | - | Lenze | i950 | |||
| 0x294A:002 | Torque limits offset: Resulting positive torque limit | I16 | x.x % (Read only) | - | Lenze | i950 | |||
| 0x294A:003 | Torque limits offset: Resulting negative torque limit | I16 | x.x % (Read only) | - | Lenze | i950 | |||
| 0x2980 | Position controller gain | U32 | 28.40 1/s | - | Lenze | i950 | |||
| 0x2981 | Position controller gain adaption | U16 | 100.00 % | - | Lenze | i950 | |||
| 0x2982 | Position controller output signal limitation | U32 | 480000.00 rpm | - | Lenze | i950 | |||
| 0x2983 | Actual position start value | I32 | 0 | - | Lenze | i950 | |||
| 0x2984 | Mode for setting the actual position | U8 | Absolute [0] | - | Lenze | i950 | |||
| 0x2986 | Resulting gain adaption | U32 | x.xx % (Read only) | - | Lenze | i950 | |||
| 0x29C0:001 | Field controller settings: Gain | U32 | 165.84 A/Vs | - | Lenze | i950, i550 | |||
| 0x29C0:002 | Field controller settings: Reset time | U16 | 15.1 ms | - | Lenze | i950, i550 | |||
| 0x29E0:001 | Field weakening controller settings: Gain (ASM) | U32 | 0.000 Vs/V | - | Lenze | i950, i550 | |||
| 0x29E0:002 | Field weakening controller settings: Reset time (ASM) | U32 | 2000.0 ms | - | Lenze | i950, i550 | |||
| 0x29E0:003 | Field weakening controller settings: Reset time (PSM) | U32 | 800.0 ms * | MCTRL | Lenze | i550 | |||
| 0x29E1 | Field weakening controller Field limitation | U16 | 100.00 % | - | Lenze | i950, i550 | |||
| 0x29E2 | DC-bus filter time | U16 | 25.0 ms | - | Lenze | i950, i550 | |||
| 0x29E3 | Motor voltage filter time | U16 | 25.0 ms | - | Lenze | i950, i550 | |||
| 0x29E4 | Voltage reserve range | U8 | 5 % | - | Lenze | i950, i550 | |||
| 0x2B00 | V/f characteristic shape | U8 | Linear [0] | C | Lenze | i950, i550 | |||
| 0x2B01:001 | V/f shape data: Base voltage | U16 | 225 V | - | Lenze | i950, i550 | |||
| 0x2B01:002 | V/f shape data: Base frequency | U16 | 270 Hz | - | Lenze | i950, i550 | |||
| 0x2B01:003 | V/f shape data: Midpoint voltage | P303.03 | U16 | 0 V | MCTRL | Lenze | i550 | ||
| 0x2B01:004 | V/f shape data: Midpoint frequency | P303.04 | U16 | 0 Hz | MCTRL | Lenze | i550 | ||
| 0x2B02:001 | Frequency grid points (x) user V/f characteristic: x1 = f01 | I16 | -50 Hz | - | Lenze | i950, i550 | |||
| 0x2B02:002 | Frequency grid points (x) user V/f characteristic: x2 = f02 | I16 | -40 Hz | - | Lenze | i950, i550 | |||
| 0x2B02:003 | Frequency grid points (x) user V/f characteristic: x3 = f03 | I16 | -30 Hz | - | Lenze | i950, i550 | |||
| 0x2B02:004 | Frequency grid points (x) user V/f characteristic: x4 = f04 | I16 | -20 Hz | - | Lenze | i950, i550 | |||
| 0x2B02:005 | Frequency grid points (x) user V/f characteristic: x5 = f05 | I16 | -10 Hz | - | Lenze | i950, i550 | |||
| 0x2B02:006 | Frequency grid points (x) user V/f characteristic: x6 = f06 | I16 | 0 Hz | - | Lenze | i950, i550 | |||
| 0x2B02:007 | Frequency grid points (x) user V/f characteristic: x7 = f07 | I16 | 10 Hz | - | Lenze | i950, i550 | |||
| 0x2B02:008 | Frequency grid points (x) user V/f characteristic: x8 = f08 | I16 | 20 Hz | - | Lenze | i950, i550 | |||
| 0x2B02:009 | Frequency grid points (x) user V/f characteristic: x9 = f09 | I16 | 30 Hz | - | Lenze | i950, i550 | |||
| 0x2B02:010 | Frequency grid points (x) user V/f characteristic: x10 = f10 | I16 | 40 Hz | - | Lenze | i950, i550 | |||
| 0x2B02:011 | Frequency grid points (x) user V/f characteristic: x11 = f11 | I16 | 50 Hz | - | Lenze | i950, i550 | |||
| 0x2B03:001 | Voltage grid points (y) user V/f characteristic: y1 = U01 (x = f01) | U32 | 400.00 V | - | Lenze | i950, i550 | |||
| 0x2B03:002 | Voltage grid points (y) user V/f characteristic: y2 = U02 (x = f02) | U32 | 320.00 V | - | Lenze | i950, i550 | |||
| 0x2B03:003 | Voltage grid points (y) user V/f characteristic: y3 = U03 (x = f03) | U32 | 240.00 V | - | Lenze | i950, i550 | |||
| 0x2B03:004 | Voltage grid points (y) user V/f characteristic: y4 = U04 (x = f04) | U32 | 160.00 V | - | Lenze | i950, i550 |