Parameters
Filters
| Title | Parameter | Display Code | Data type | Default setting | Attributes | Fieldbus | Manufacturer | Product category | Operations |
|---|---|---|---|---|---|---|---|---|---|
| 0x2923:031 | Internal: Identified pole 2 - real part | I32 | 0.000 1/s | - | Lenze | i950 | |||
| 0x2923:032 | Internal: Identified pole 2 - imaginary part | I32 | 0.000 1/s | - | Lenze | i950 | |||
| 0x2923:033 | Internal: Identified pole 3 - real part | I32 | 0.000 1/s | - | Lenze | i950 | |||
| 0x2923:034 | Internal: Identified pole 3 - imaginary part | I32 | 0.000 1/s | - | Lenze | i950 | |||
| 0x2923:035 | Internal: Identified pole 4 - real part | I32 | 0.000 1/s | - | Lenze | i950 | |||
| 0x2923:036 | Internal: Identified pole 4 - imaginary part | I32 | 0.000 1/s | - | Lenze | i950 | |||
| 0x2923:050 | Internal: Identified result - motor moment of inertia | U32 | 0.00 kg cm² | - | Lenze | i950 | |||
| 0x2923:051 | Internal: Identified result - load 1 moment of inertia | U32 | 0.00 kg cm² | - | Lenze | i950 | |||
| 0x2923:052 | Internal: Identified result - load 2 moment of inertia | U32 | 0.00 kg cm² | - | Lenze | i950 | |||
| 0x2923:054 | Internal: Identified result - coupling between motor and load 1 | U32 | 0.00 | - | Lenze | i950 | |||
| 0x2923:055 | Internal: Identified result - coupling between load 1 and load 2 | U32 | 0.00 | - | Lenze | i950 | |||
| 0x2923:057 | Internal: Identified result - damping between motor and load 1 | U32 | 0.00 | - | Lenze | i950 | |||
| 0x2923:058 | Internal: Identified result - damping between load 1 and load 2 | U32 | 0.00 | - | Lenze | i950 | |||
| 0x2939 | Switching frequency | U8 | 4 kHz variable / drive-optimised [1] | - | Lenze | i950, i550 | |||
| 0x293A | Actual switching frequency | P116.00 | U8 | - (Read only) | general | Lenze | i550 | ||
| 0x2941 | Current controller feedforward control | U8 | Disable [0] | - | Lenze | i950 | |||
| 0x2942:001 | Current controller parameters: Gain | U32 | 148.21 V/A | - | Lenze | i950, i550 | |||
| 0x2942:002 | Current controller parameters: Reset time | U32 | 3.77 ms | - | Lenze | i950, i550 | |||
| 0x2942:004 | Current controller parameters: d-axis gain | U32 | 26.00 V/A * | MCTRL | Lenze | i550 | |||
| 0x2942:005 | Current controller parameters: d-axis reset time | U32 | 3.00 ms * | MCTRL | Lenze | i550 | |||
| 0x2942:006 | Current controller parameters: q-axis gain | U32 | 26.00 V/A * | MCTRL | Lenze | i550 | |||
| 0x2942:007 | Current controller parameters: q-axis reset time | U32 | 3.00 ms * | MCTRL | Lenze | i550 | |||
| 0x2943 | Current setpoint filter time | U16 | 0.00 ms | - | Lenze | i950 | |||
| 0x2944:001 | Torque setpoint notch filter: Frequency notch filter 1 | U16 | 200.0 Hz | - | Lenze | i950 | |||
| 0x2944:002 | Torque setpoint notch filter: Bandwidth notch filter 1 | U16 | 20.0 Hz | - | Lenze | i950 | |||
| 0x2944:003 | Torque setpoint notch filter: Damping notch filter 1 | U8 | 0 dB | - | Lenze | i950 | |||
| 0x2944:004 | Torque setpoint notch filter: Frequency notch filter 2 | U16 | 400.0 Hz | - | Lenze | i950 | |||
| 0x2944:005 | Torque setpoint notch filter: Bandwidth notch filter 2 | U16 | 40.0 Hz | - | Lenze | i950 | |||
| 0x2944:006 | Torque setpoint notch filter: Damping notch filter 2 | U8 | 0 dB | - | Lenze | i950 | |||
| 0x2945 | Torque setpoint jerk limitation | U16 | 400.0 | - | Lenze | i950 | |||
| 0x2946:001 | Speed limitation: Upper speed limit | I32 | 0 rpm | - | Lenze | i950, i550 | |||
| 0x2946:002 | Speed limitation: Lower speed limit | I32 | 0 rpm | - | Lenze | i950, i550 | |||
| 0x2946:003 | Speed limitation: Upper speed limit source | P340.03 | U8 | Maximum frequency [0] | general | Lenze | i550 | ||
| 0x2946:004 | Speed limitation: Lower speed limit source | P340.04 | U8 | (-) Maximum frequency [0] | general | Lenze | i550 | ||
| 0x2946:005 | Speed limitation: Upper frequency limit | P340.05 | I16 | Device for 50-Hz mains: 50.0 Hz Device for 60-Hz mains: 60.0 Hz | general | Lenze | i550 | ||
| 0x2946:006 | Speed limitation: Lower frequency limit | P340.06 | I16 | Device for 50-Hz mains: -50.0 Hz Device for 60-Hz mains: -60.0 Hz | general | Lenze | i550 | ||
| 0x2946:007 | Speed limitation: Actual upper speed limit | P340.07 | I16 | x.x Hz (Read only) | general | Lenze | i550 | ||
| 0x2946:008 | Speed limitation: Actual lower speed limit | P340.08 | I16 | x.x Hz (Read only) | general | Lenze | i550 | ||
| 0x2947:001 | Inverter characteristic: Value y1 | U16 | 0.00 V | - | Lenze | i950 | |||
| 0x2947:001 ... 0x2947:017 | Inverter characteristic: Value y1 ... Value y17 | U16 | 0.00 V * | MCTRL | Lenze | i550 | |||
| 0x2947:002 | Inverter characteristic: Value y2 | U16 | 0.00 V | - | Lenze | i950 | |||
| 0x2947:003 | Inverter characteristic: Value y3 | U16 | 0.00 V | - | Lenze | i950 | |||
| 0x2947:004 | Inverter characteristic: Value y4 | U16 | 0.00 V | - | Lenze | i950 | |||
| 0x2947:005 | Inverter characteristic: Value y5 | U16 | 0.00 V | - | Lenze | i950 | |||
| 0x2947:006 | Inverter characteristic: Value y6 | U16 | 0.00 V | - | Lenze | i950 | |||
| 0x2947:007 | Inverter characteristic: Value y7 | U16 | 0.00 V | - | Lenze | i950 | |||
| 0x2947:008 | Inverter characteristic: Value y8 | U16 | 0.00 V | - | Lenze | i950 | |||
| 0x2947:009 | Inverter characteristic: Value y9 | U16 | 0.00 V | - | Lenze | i950 | |||
| 0x2947:010 | Inverter characteristic: Value y10 | U16 | 0.00 V | - | Lenze | i950 | |||
| 0x2947:011 | Inverter characteristic: Value y11 | U16 | 0.00 V | - | Lenze | i950 |