Parameters

Filters
Title Parameter Display Code Data type Default setting Attributes Fieldbus Manufacturer Product category Operations
0x2822:026 Axis commands: Get motor encoder information (HIPERFACE®) U8 Off/Ready [0] - Lenze i950
0x2822:027 Axis commands: Calculate SLVC controller parameter U8 RANLI_C2822_S027_GEN_V00000000 [0] - Lenze i950
0x2822:029 Axis commands: Get load encoder/master encoder characteristic (resolver) U8 Off/Ready [0] - Lenze i950
0x2822:030 Axis commands: Get load encoder/master encoder information (HIPERFACE®) U8 Off/Ready [0] - Lenze i950
0x2822:037 Axis commands: Estimate all motor parameters based on rated data U8 Off/Ready [0] - Lenze i950
0x2822:038 Axis commands: HIPERFACE (A): Set position with synchronization U8 Off/Ready [0] - Lenze i950
0x2822:039 Axis commands: HIPERFACE (A): Set position with synchronization U8 Off/Ready [0] - Lenze i950
0x2822:042 Axis commands: Calculate speed filter time constant U8 Off/Ready [0] - Lenze i950
0x2822:043 Axis commands: Load power dependent motor parameters U8 RANLI_C2822_S043_GEN_V00000000 [0] - Lenze i950
0x2822:044 Axis commands: Cogging torque compensation U8 RANLI_C2822_S044_GEN_V00000000 [0] - Lenze i950
0x2823 Status of axis commands U8 x % (Read only) - Lenze i950
0x2824 Control via PDO/Application U8 Keypad [1] C Lenze i950, i550
0x2825 Drive mode selection U8 CiA402 operating modes [0] C Lenze i950
0x2826 Timeout for error response -> quickstop U32 4 s - Lenze i950, i550
0x2827 Currently loaded parameter settings P198.00 U8 - (Read only) general Lenze i550
0x2829 Automatic storage in the memory module P732.00 U8 Inhibit [0] general Lenze i550
0x282A:001 Status words: Cause of disable U32 - (Read only) H Lenze i950, i550
0x282A:002 Status words: Cause of quick stop P126.02 U16 - (Read only) general Lenze i550
0x282A:003 Status words: Cause of stop P126.03 U16 - (Read only) general Lenze i550
0x282A:004 Status words: Extended status word U16 - (Read only) H Lenze i950, i550
0x282A:005 Status words: Device status P126.05 U8 - (Read only) general Lenze i550
0x282B:001 Inverter diagnostics: Active control source P125.01 U8 - (Read only) general Lenze i550
0x282B:002 Inverter diagnostics: Active setpoint source P125.02 U8 - (Read only) general Lenze i550
0x282B:003 Inverter diagnostics: Keypad LCD status P125.03 U8 - (Read only) general Lenze i550
0x282B:004 Inverter diagnostics: Active drive mode P125.04 U8 - (Read only) general Lenze i550
0x282B:005 Inverter diagnostics: Most recently used control register P125.05 U32 - (Read only) general Lenze i550
0x282B:006 Inverter diagnostics: Most recently used setpoint register P125.06 U32 - (Read only) general Lenze i550
0x282B:007 Inverter diagnostics: Default frequency setpoint I16 x.x Hz (Read only) general Lenze i550
0x282B:008 Inverter diagnostics: Preset frequency setpoint I16 x.x Hz (Read only) general Lenze i550
0x282B:009 Inverter diagnostics: Actual frequency setpoint I16 x.x Hz (Read only) general Lenze i550
0x282B:010 Inverter diagnostics: Default PID setpoint I16 x.xx PID unit (Read only) general Lenze i550
0x282B:011 Inverter diagnostics: Preset PID setpoint I16 x.xx PID unit (Read only) general Lenze i550
0x282B:012 Inverter diagnostics: Default torque setpoint I16 x.x % (Read only) general Lenze i550
0x282B:013 Inverter diagnostics: Preset torque setpoint I16 x.x % (Read only) general Lenze i550
0x282C:001 I/O diagnostic: Application level of the digital inputs U32 - (Read only) H Lenze i950
0x282C:002 I/O diagnostic: Digital output levels U32 - (Read only) H Lenze i950
0x2830 Inverter control word U16 0x0000 H Lenze i950
0x2831 Inverter status word U16 - (Read only) H Lenze i950, i550
0x2832 Identification status U16 - (Read only) H Lenze i950
0x2833 Inverter status word 2 U16 - (Read only) H Lenze i950, i550
0x2835:001 Manual test mode: Current setpoint I16 0 % - Lenze i950
0x2835:002 Manual test mode: Frequency I16 0.0 Hz - Lenze i950
0x2835:003 Manual test mode: Starting angle I16 0.0 ° - Lenze i950
0x2836:001 Manual control mode: Current setpoint U16 30 % - Lenze i950
0x2836:002 Manual control mode: Frequency I16 0.0 Hz - Lenze i950
0x2836:003 Manual control mode: Ramp time (current) U16 0 ms - Lenze i950
0x2836:004 Manual control mode: Ramp time (frequency) U16 500 ms - Lenze i950
0x2836:005 Manual control mode: Time monitoring (frequency) U32 2500 ms - Lenze i950
0x2836:006 Manual control mode: Current controller gain U32 20.00 V/A - Lenze i950
0x2836:007 Manual control mode: Current controller reset time U32 20.00 ms - Lenze i950
← Previous Page 25 of 58 Next →