Parameters

Filters
Title Parameter Display Code Data type Default setting Attributes Fieldbus Manufacturer Product category Operations
0x2640:008 HTL input settings: Maximum torque setpoint P415.08 I16 100.0 % general Lenze i550
0x2640:009 HTL input settings: IN1 Filter time constant P415.09 U16 10 ms general Lenze i550
0x2641:001 HTL input monitoring: IN1 Minimal frequency threshold P416.01 I32 0.0 Hz general Lenze i550
0x2641:002 HTL input monitoring: IN1 Minimum delay threshold P416.02 U16 5.0 s general Lenze i550
0x2641:003 HTL input monitoring: IN1 Maximal frequency threshold P416.03 I32 0.0 Hz general Lenze i550
0x2641:004 HTL input monitoring: IN1 Maximum delay threshold P416.04 U16 5.0 s general Lenze i550
0x2641:005 HTL input monitoring: IN 1Monitoring conditions P416.05 U8 Below minimum frequency [1] general Lenze i550
0x2641:006 HTL input monitoring: IN1 Error response P416.06 U8 No response [0] general Lenze i550
0x2642:001 HTL input diagnostics: Input frequency P115.01 I32 x.x Hz (Read only) general Lenze i550
0x2642:002 HTL input diagnostics: Frequency setpoint P115.02 I16 x.x Hz (Read only) general Lenze i550
0x2642:003 HTL input diagnostics: PID setpoint P115.03 I16 x.xx PID unit (Read only) general Lenze i550
0x2642:004 HTL input diagnostics: Torque setpoint P115.04 I16 x.x % (Read only) general Lenze i550
0x2644:001 DO1 frequency setup: Minimum frequency P423.01 I32 0.0 Hz general Lenze i550
0x2644:002 DO1 frequency setup: Maximum frequency P423.02 I32 10000.0 Hz general Lenze i550
0x2644:003 DO1 frequency setup: Function P423.03 U8 Not active [0] general Lenze i550
0x2644:004 DO1 frequency setup: Minimum signal P423.04 I32 0 general Lenze i550
0x2644:005 DO1 frequency setup: Maximum signal P423.05 I32 1000 general Lenze i550
0x2646:001 DO actual frequency: Digital output 1 P114.01 I32 x.x Hz (Read only) general Lenze i550
0x2811:003 Motor mounting direction U8 Not inverted [0] MCTRL Lenze i550
0x2820:001 Holding brake control: Brake mode U8 Off [2] - Lenze i950, i550
0x2820:002 Holding brake control: Brake closing time U16 100 ms - Lenze i950, i550
0x2820:003 Holding brake control: Brake opening time U16 100 ms - Lenze i950, i550
0x2820:004 Holding brake control: Brake detection U16 - (Read only) - Lenze i950
0x2820:005 Holding brake control: Brake polarity U8 Normal [0] - Lenze i950
0x2820:006 Holding brake control: Brake error response U8 Fault > CiA402 [1] - Lenze i950
0x2820:007 Holding brake control: Brake closing threshold P712.07 U16 0.2 Hz general Lenze i550
0x2820:008 Holding brake control: Brake holding load P712.08 I16 0.0 % general Lenze i550
0x2820:009 Holding brake control: Starting torque source U16 Torque in 0x2820:010 [1] - Lenze i950
0x2820:010 Holding brake control: Starting torque I16 0.0 % - Lenze i950
0x2820:011 Holding brake control: Override of the brake control U8 No override active [0] - Lenze i950
0x2820:012 Holding brake control: Closing threshold delay P712.12 U16 0 ms general Lenze i550
0x2820:013 Holding brake control: Holding load ramptime U16 0 ms - Lenze i950, i550
0x2820:015 Holding brake control: Brake status U8 - (Read only) - Lenze i950, i550
0x2820:019 Holding brake control: Brake opening time test signal U16 500 ms - Lenze i950
0x2820:020 Holding brake control: Brake control word U8 0x00 H Lenze i950
0x2820:021 Holding brake control: Detected actual torque I16 x.x % (Read only) - Lenze i950
0x2820:022 Holding brake control: Holding brake supply voltage U8 No reduction [100] - Lenze i950
0x2820:023 Holding brake control: Control configuration U8 Via internal brake module [0] - Lenze i950
0x2822:001 Axis commands: Enable inverter U8 Inverter enabled [1] - Lenze i950
0x2822:003 Axis commands: Reset error U8 Off/Ready [0] - Lenze i950
0x2822:004 Identify motor data (energized) P327.04 U8 0 general Lenze i550
0x2822:005 Calibrate motor data (non-energized) P327.05 U8 0 general Lenze i550
0x2822:006 Motor identification U8 0 general Lenze i550
0x2822:010 Identify inverter characteristic U8 0 general Lenze i550
0x2822:019 Calculate Imax controller parameter U8 0 general Lenze i550
0x2822:021 Axis commands: Load default Lh saturation characteristic U8 Off/Ready [0] - Lenze i950
0x2822:022 Axis commands: Load default inverter characteristic U8 Off/Ready [0] - Lenze i950
0x2822:023 Axis commands: Estimate optimum magnetizing current U8 Off/Ready [0] - Lenze i950
0x2822:024 Axis commands: Estimate basic motor parameters based on rated data U8 Off/Ready [0] - Lenze i950
0x2822:025 Axis commands: Get motor encoder characteristic (resolver) U8 Off/Ready [0] - Lenze i950
← Previous Page 24 of 58 Next →