Parameters

Filters
Title Parameter Display Code Data type Default setting Attributes Fieldbus Manufacturer Product category Operations
0x2637:005 Analog input 2: Max PID value P431.05 I16 100.00 PID unit general Lenze i550
0x2637:006 Analog input 2: Filter time U16 10 ms - Lenze i950, i550
0x2637:007 Analog input 2: Dead band U16 0.0 % - Lenze i950, i550
0x2637:008 Analog input 2: Monitoring threshold P431.08 I16 0.0 % general Lenze i550
0x2637:009 Analog input 2: Monitoring condition P431.09 U8 Input value < trigger threshold [0] general Lenze i550
0x2637:010 Analog input 2: Error response U8 No response [0] - Lenze i950, i550
0x2637:011 Analog input 2: Min torque value P431.11 I16 0.0 % general Lenze i550
0x2637:012 Analog input 2: Max torque value P431.12 I16 100.0 % general Lenze i550
0x2637:013 Analog input 2: Minimum value for scaling I16 0.0 % - Lenze i950
0x2637:014 Analog input 2: Maximum value for scaling I16 100.0 % - Lenze i950
0x2639:001 Analog output 1: Output range U8 Inhibited [0] - Lenze i950, i550
0x2639:002 Analog output 1: Function P440.02 U8 Output frequency [1] general Lenze i550
0x2639:003 Analog output 1: Min. signal I16 0.0 - Lenze i950, i550
0x2639:004 Analog output 1: Max. signal I16 100.0 - Lenze i950, i550
0x2639:005 Analog output 1: Scaled percent value I16 0.00 % - Lenze i950
0x2639:006 Analog output 1: Filter time P440.06 U16 250 ms general Lenze i550
0x263A:001 Analog output 2: Output range P441.01 U8 0 ... 10 VDC [1] Appl. I/O Lenze i550
0x263A:002 Analog output 2: Function P441.02 U8 Motor current [5] Appl. I/O Lenze i550
0x263A:003 Analog output 2: Min. signal P441.03 I32 0 Appl. I/O Lenze i550
0x263A:004 Analog output 2: Max. signal P441.04 I32 1000 Appl. I/O Lenze i550
0x263A:006 Analog output 2: Filter time P441.06 U16 250 ms Appl. I/O Lenze i550
0x263B:001 Digital inputs internal control: Activation U8 Off [0] - Lenze i950
0x263B:002 Digital inputs internal control: DI1 internal control U8 Off [0] - Lenze i950
0x263B:003 Digital inputs internal control: DI2 internal control U8 Off [0] - Lenze i950
0x263B:004 Digital inputs internal control: DI3 internal control U8 Off [0] - Lenze i950
0x263B:005 Digital inputs internal control: DI4 internal control U8 Off [0] - Lenze i950
0x263B:006 Digital inputs internal control: DI5 internal control U8 Off [0] - Lenze i950
0x263B:007 Digital inputs internal control: DI6 internal control U8 Off [0] - Lenze i950
0x263B:008 Digital inputs internal control: DI7 internal control U8 Off [0] - Lenze i950
0x263B:009 Digital inputs internal control: DI8 internal control U8 Off [0] - Lenze i950
0x263B:010 Digital inputs internal control: DI9 internal control U8 Off [0] - Lenze i950
0x263C:001 Digital outputs internal control: Activation U8 Off [0] - Lenze i950
0x263C:002 Digital outputs internal control: DO1 internal control U8 Off [0] - Lenze i950
0x263C:003 Digital outputs internal control: DO2 internal control U8 Off [0] - Lenze i950
0x263C:004 Digital outputs internal control: DO3 internal control U8 Off [0] - Lenze i950
0x263C:005 Digital outputs internal control: DO4 internal control U8 Off [0] - Lenze i950
0x263C:006 Digital outputs internal control: DO5 internal control U8 Off [0] - Lenze i950
0x263C:007 Digital outputs internal control: DO6 internal control U8 Off [0] - Lenze i950
0x263D:001 Analog inputs internal control: Activation U8 Off [0] - Lenze i950
0x263D:002 Analog inputs internal control: AI1 internal control I16 100.00 % - Lenze i950
0x263D:003 Analog inputs internal control: AI2 internal control I16 100.00 % - Lenze i950
0x263E:001 Activation U8 Off [0] - Lenze i950
0x263E:002 AO1 internal control I16 100.00 % - Lenze i950
0x2640:001 HTL input settings: Minimum frequency P415.01 I32 0.0 Hz general Lenze i550
0x2640:002 HTL input settings: Maximum frequency P415.02 I32 0.0 Hz general Lenze i550
0x2640:003 HTL input settings: Minimum motor frequency P415.03 I16 0.0 Hz general Lenze i550
0x2640:004 HTL input settings: Maximum motor frequency P415.04 I16 Device for 50-Hz mains: 50.0 Hz Device for 60-Hz mains: 60.0 Hz general Lenze i550
0x2640:005 HTL input settings: Minimum PID setpoint P415.05 I16 0.00 PID unit general Lenze i550
0x2640:006 HTL input settings: Maximum PID setpoint P415.06 I16 100.00 PID unit general Lenze i550
0x2640:007 HTL input settings: Minimum torque setpoint P415.07 I16 0.0 % general Lenze i550
← Previous Page 23 of 58 Next →