0x2634:017 Digital outputs function: NetWordOUT1 - bit 7 P420.17 U8 Device warning active [58] general Lenze i550
0x2634:018 Digital outputs function: NetWordOUT1 - bit 8 P420.18 U8 Not connected [0] general Lenze i550
0x2634:019 Digital outputs function: NetWordOUT1 - bit 9 P420.19 U8 Not connected [0] general Lenze i550
0x2634:020 Digital outputs function: NetWordOUT1 - bit 10 P420.20 U8 Setpoint speed reached [72] general Lenze i550
0x2634:021 Digital outputs function: NetWordOUT1 - bit 11 P420.21 U8 Current limit reached [78] general Lenze i550
0x2634:022 Digital outputs function: NetWordOUT1 - bit 12 P420.22 U8 Actual speed = 0 [71] general Lenze i550
0x2634:023 Digital outputs function: NetWordOUT1 - bit 13 P420.23 U8 Rotational direction reversed [69] general Lenze i550
0x2634:024 Digital outputs function: NetWordOUT1 - bit 14 P420.24 U8 Release holding brake [115] general Lenze i550
0x2634:025 Digital outputs function: NetWordOUT1 - bit 15 P420.25 U8 Inverter disabled (safety) [55] general Lenze i550
0x2635:001 Inversion of digital outputs: Relay P421.01 U8 Not inverted [0] general Lenze i550
0x2635:002 Inversion of digital outputs: Digital output 1 U8 Not inverted [0] - Lenze i950, i550
0x2635:003 Inversion of digital outputs: Digital output 2 U8 Not inverted [0] - Lenze i950, i550
0x2635:004 Inversion of digital outputs: Digital output 3 U8 Not inverted [0] - Lenze i950
0x2635:005 Inversion of digital outputs: Digital output 4 U8 Not inverted [0] - Lenze i950
0x2635:006 Inversion of digital outputs: Digital output 5 U8 Not inverted [0] - Lenze i950
0x2635:007 Inversion of digital outputs: Digital output 6 U8 Not inverted [0] - Lenze i950
0x2635:010 Inversion of digital outputs: NetWordOUT1.00 U8 Not inverted [0] general Lenze i550
0x2635:011 Inversion of digital outputs: NetWordOUT1.01 U8 Not inverted [0] general Lenze i550
0x2635:012 Inversion of digital outputs: NetWordOUT1.02 U8 Not inverted [0] general Lenze i550
0x2635:013 Inversion of digital outputs: NetWordOUT1.03 U8 Not inverted [0] general Lenze i550
0x2635:014 Inversion of digital outputs: NetWordOUT1.04 U8 Not inverted [0] general Lenze i550
0x2635:015 Inversion of digital outputs: NetWordOUT1.05 U8 Not inverted [0] general Lenze i550
0x2635:016 Inversion of digital outputs: NetWordOUT1.06 U8 Not inverted [0] general Lenze i550
0x2635:017 Inversion of digital outputs: NetWordOUT1.07 U8 Not inverted [0] general Lenze i550
0x2635:018 Inversion of digital outputs: NetWordOUT1.08 U8 Not inverted [0] general Lenze i550
0x2635:019 Inversion of digital outputs: NetWordOUT1.09 U8 Not inverted [0] general Lenze i550
0x2635:020 Inversion of digital outputs: NetWordOUT1.10 U8 Not inverted [0] general Lenze i550
0x2635:021 Inversion of digital outputs: NetWordOUT1.11 U8 Not inverted [0] general Lenze i550
0x2635:022 Inversion of digital outputs: NetWordOUT1.12 U8 Not inverted [0] general Lenze i550
0x2635:023 Inversion of digital outputs: NetWordOUT1.13 U8 Not inverted [0] general Lenze i550
0x2635:024 Inversion of digital outputs: NetWordOUT1.14 U8 Not inverted [0] general Lenze i550
0x2635:025 Inversion of digital outputs: NetWordOUT1.15 U8 Not inverted [0] general Lenze i550
0x2636:001 Analog input 1: Input range U8 0 ... 10 VDC [0] - Lenze i950, i550
0x2636:002 Analog input 1: Min frequency value P430.02 I16 0.0 Hz general Lenze i550
0x2636:003 Analog input 1: Max frequency value P430.03 I16 Device for 50-Hz mains: 50.0 Hz Device for 60-Hz mains: 60.0 Hz general Lenze i550
0x2636:004 Analog input 1: Min PID value P430.04 I16 0.00 PID unit general Lenze i550
0x2636:005 Analog input 1: Max PID value P430.05 I16 100.00 PID unit general Lenze i550
0x2636:006 Analog input 1: Filter time U16 10 ms - Lenze i950, i550
0x2636:007 Analog input 1: Dead band U16 0.0 % - Lenze i950, i550
0x2636:008 Analog input 1: Monitoring threshold P430.08 I16 0.0 % general Lenze i550
0x2636:009 Analog input 1: Monitoring condition P430.09 U8 Input value < trigger threshold [0] general Lenze i550
0x2636:010 Analog input 1: Error response U8 No response [0] - Lenze i950, i550
0x2636:011 Analog input 1: Min torque value P430.11 I16 0.0 % general Lenze i550
0x2636:012 Analog input 1: Max torque value P430.12 I16 100.0 % general Lenze i550
0x2636:013 Analog input 1: Minimum value for scaling I16 0.0 % - Lenze i950
0x2636:014 Analog input 1: Maximum value for scaling I16 100.0 % - Lenze i950
0x2637:001 Analog input 2: Input range U8 0 ... 10 VDC [0] - Lenze i950, i550
0x2637:002 Analog input 2: Min frequency value P431.02 I16 0.0 Hz general Lenze i550
0x2637:003 Analog input 2: Max frequency value P431.03 I16 Device for 50-Hz mains: 50.0 Hz Device for 60-Hz mains: 60.0 Hz general Lenze i550
0x2637:004 Analog input 2: Min PID value P431.04 I16 0.00 PID unit general Lenze i550