0x2631:036 Function list: Abort sequence P400.36 U8 Not connected [0] Sequencer Lenze i550
0x2631:037 Function list: Activate network control P400.37 U8 Not connected [0] general Lenze i550
0x2631:039 Function list: Activate ramp 2 P400.39 U8 Not connected [0] general Lenze i550
0x2631:040 Function list: Load parameter set P400.40 U8 Not connected [0] general Lenze i550
0x2631:041 Function list: Select parameter set (bit 0) P400.41 U8 Not connected [0] general Lenze i550
0x2631:042 Function list: Select parameter set (bit 1) P400.42 U8 Not connected [0] general Lenze i550
0x2631:043 Function list: Activate fault 1 P400.43 U8 Not connected [0] general Lenze i550
0x2631:044 Function list: Activate fault 2 P400.44 U8 Not connected [0] general Lenze i550
0x2631:045 Function list: Disable PID controller P400.45 U8 Not connected [0] general Lenze i550
0x2631:046 Function list: Set process controller output to 0 P400.46 U8 Not connected [0] general Lenze i550
0x2631:047 Function list: Inhibit process controller I-component P400.47 U8 Not connected [0] general Lenze i550
0x2631:048 Function list: Activate PID influence ramp P400.48 U8 Constant TRUE [1] general Lenze i550
0x2631:049 Function list: Open holding brake P400.49 U8 Not connected [0] general Lenze i550
0x2631:050 Function list: Select sequence (bit 0) P400.50 U8 Not connected [0] Sequencer Lenze i550
0x2631:051 Function list: Select sequence (bit 1) P400.51 U8 Not connected [0] Sequencer Lenze i550
0x2631:052 Function list: Select sequence (bit 2) P400.52 U8 Not connected [0] Sequencer Lenze i550
0x2631:053 Function list: Select sequence (bit 3) P400.53 U8 Not connected [0] Sequencer Lenze i550
0x2631:054 Function list: Set position counter P400.54 U8 Not connected [0] general Lenze i550
0x2631:055 Function list: Activate UPS operation P400.55 U8 Not connected [0] general Lenze i550
0x2631:056 Function list: Assist pump 1 P400.56 U8 Not connected [0] Lenze i550
0x2631:057 Function list: Assist pump 2 P400.57 U8 Not connected [0] Lenze i550
0x2631:058 Function list: Reset operating time P400.58 U8 Not connected [0] Lenze i550
0x2632:001 Inversion of digital inputs: Digital input 1 U8 Not inverted [0] - Lenze i950, i550
0x2632:002 Inversion of digital inputs: Digital input 2 U8 Not inverted [0] - Lenze i950, i550
0x2632:003 Inversion of digital inputs: Digital input 3 U8 Not inverted [0] - Lenze i950, i550
0x2632:004 Inversion of digital inputs: Digital input 4 U8 Not inverted [0] - Lenze i950, i550
0x2632:005 Inversion of digital inputs: Digital input 5 U8 Not inverted [0] - Lenze i950, i550
0x2632:006 Inversion of digital inputs: Digital input 6 U8 Not inverted [0] - Lenze i950, i550
0x2632:007 Inversion of digital inputs: Digital input 7 U8 Not inverted [0] - Lenze i950, i550
0x2632:008 Inversion of digital inputs: Digital input 8 U8 Not inverted [0] - Lenze i950
0x2632:009 Inversion of digital inputs: Digital input 9 U8 Not inverted [0] - Lenze i950
0x2633:001 Digital input debounce time: Digital input 1 U8 0 ms - Lenze i950, i550
0x2633:002 Digital input debounce time: Digital input 2 U8 0 ms - Lenze i950, i550
0x2633:003 Digital input debounce time: Digital input 3 U8 0 ms - Lenze i950, i550
0x2633:004 Digital input debounce time: Digital input 4 U8 0 ms - Lenze i950, i550
0x2633:005 Digital input debounce time: Digital input 5 U8 0 ms - Lenze i950, i550
0x2633:006 Digital input debounce time: Digital input 6 U8 0 ms - Lenze i950, i550
0x2633:007 Digital input debounce time: Digital input 7 U8 0 ms - Lenze i950, i550
0x2633:008 Digital input debounce time: Digital input 8 U8 0 ms - Lenze i950
0x2633:009 Digital input debounce time: Digital input 9 U8 0 ms - Lenze i950
0x2634:001 Digital outputs function: Relay P420.01 U8 Ready for operation [51] general Lenze i550
0x2634:002 Digital outputs function: Digital output 1 U8 Signal from application [10] - Lenze i950, i550
0x2634:003 Digital outputs function: Digital output 2 P420.03 U8 Fault active [56] Appl. I/O Lenze i550
0x2634:010 Digital outputs function: NetWordOUT1 - bit 0 P420.10 U8 Ready for operation [51] general Lenze i550
0x2634:011 Digital outputs function: NetWordOUT1 - bit 1 P420.11 U8 Not connected [0] general Lenze i550
0x2634:012 Digital outputs function: NetWordOUT1 - bit 2 P420.12 U8 Operation enabled [52] general Lenze i550
0x2634:013 Digital outputs function: NetWordOUT1 - bit 3 P420.13 U8 Fault active [56] general Lenze i550
0x2634:014 Digital outputs function: NetWordOUT1 - bit 4 P420.14 U8 Not connected [0] general Lenze i550
0x2634:015 Digital outputs function: NetWordOUT1 - bit 5 P420.15 U8 Quick stop active [54] general Lenze i550
0x2634:016 Digital outputs function: NetWordOUT1 - bit 6 P420.16 U8 Running [50] general Lenze i550