Parameters

Filters
Title Parameter Display Code Data type Default setting Attributes Fieldbus Manufacturer Product category Operations
0x2838:001 Start/stop configuration: Start method P203.01 U8 Normal [0] MCTRL Lenze i550
0x2838:002 Start/stop configuration: Start at power-up P203.02 U8 Off [0] general Lenze i550
0x2838:003 Start/stop configuration: Stop method P203.03 U8 Standard ramp [1] general Lenze i550
0x2839:002 Fault configuration: Restart delay P760.02 U16 3.0 s general Lenze i550
0x2839:003 Fault configuration: Number of restart attempts P760.03 U8 5 general Lenze i550
0x2839:004 Fault configuration: Trouble counter reset time P760.04 U16 40.0 s general Lenze i550
0x2839:005 Fault configuration: Trouble counter P760.05 U8 - (Read only) general Lenze i550
0x2839:006 Fault configuration: Fault handling in case of state change P760.06 U8 Reset fault [0] general Lenze i550
0x283A Limitation of rotation P304.00 U8 Both rotational directions [1] general Lenze i550
0x2840 Error reset time I32 x ms (Read only) - Lenze i950
0x2841 Reset error U8 0 - Lenze i950
0x284E:001 Additional error information: Component ID U16 - (Read only) - Lenze i950
0x284F Current error OCTET[64] - (Read only) - Lenze i950
0x2857:001 CANopen monitoring: RPDO1-Timeout U8 Warning [2] - Lenze i950, i550
0x2857:002 CANopen monitoring: RPDO2-Timeout U8 Warning [2] - Lenze i950, i550
0x2857:003 CANopen monitoring: RPDO3-Timeout U8 Warning [2] - Lenze i950, i550
0x2857:004 CANopen monitoring: RPDO4-Timeout U8 Warning [2] - Lenze i950
0x2857:005 CANopen monitoring: Heartbeat-Timeout Consumer 1 U8 Warning [2] - Lenze i950, i550
0x2857:006 CANopen monitoring: Heartbeat-Timeout Consumer 2 U8 Warning [2] - Lenze i950, i550
0x2857:007 CANopen monitoring: Heartbeat-Timeout Consumer 3 U8 Warning [2] - Lenze i950, i550
0x2857:008 CANopen monitoring: Heartbeat-Timeout Consumer 4 U8 Warning [2] - Lenze i950, i550
0x2857:010 CANopen monitoring: "Bus-off" state change U8 Warning [2] - Lenze i950, i550
0x2857:011 CANopen monitoring: Warning U8 Warning [2] - Lenze i950, i550
0x2858:001 Modbus monitoring: Response to time-out P515.01 U8 Fault [3] Modbus RTU Lenze i550
0x2858:002 Modbus monitoring: Time-out time P515.02 U16 2.0 s Modbus RTU Lenze i550
0x2859:001 Network monitoring: Watchdog elapsed U8 Warning [2] - Lenze i950, i550
0x2859:002 Network monitoring: Data exchange exited U8 No response [0] - Lenze i950, i550
0x2859:003 Network monitoring: Invalid configuration U8 Warning [2] - Lenze i950, i550
0x2859:004 Network monitoring: Initialisation error U8 Warning [2] - Lenze i950, i550
0x2859:005 Network monitoring: Invalid process data U8 Warning [2] - Lenze i950, i550
0x2859:006 Network monitoring: Time-out explicit message U8 Warning [2] - Lenze i950, i550
0x2859:007 Network monitoring: Timeout communication U8 Warning [2] - Lenze i950, i550
0x2859:008 Modbus TCP/IP monitoring: Fault response to master timeout P515.08 U8 Fault [3] Modbus TCP/IP Lenze i550
0x2859:009 Modbus TCP/IP monitoring: Fault response to keep alive timeout P515.09 U8 Fault [3] Modbus TCP/IP Lenze i550
0x2859:010 POWERLINK monitoring: CRC error U8 Trouble [2] POWERLINK Lenze i550
0x2859:011 POWERLINK monitoring: Loss of SoC U8 Trouble [2] POWERLINK Lenze i550
0x285A:001 Diagnostic configuration: Alarm suppression U16 0x0000 H Lenze i950, i550
0x285B:001 onboard EtherCAT monitoring: Watchdog elapsed U8 Fault > CiA402 [1] - Lenze i950
0x285B:002 onboard EtherCAT monitoring: EtherCAT role check U8 Warning [2] - Lenze i950
0x285C:001 Alarm supression: Entry 1 U32 0x00000000 Fieldbus Lenze i550
0x285C:002 Alarm supression: Entry 2 U32 0x00000000 Fieldbus Lenze i550
0x285C:003 Alarm supression: Entry 3 U32 0x00000000 Fieldbus Lenze i550
0x285C:004 Alarm supression: Entry 4 U32 0x00000000 Fieldbus Lenze i550
0x285C:005 Alarm supression: Entry 5 U32 0x00000000 Fieldbus Lenze i550
0x285C:006 Alarm supression: Entry 6 U32 0x00000000 Fieldbus Lenze i550
0x285C:007 Alarm supression: Entry 7 U32 0x00000000 Fieldbus Lenze i550
0x285C:008 Alarm supression: Entry 8 U32 0x00000000 Fieldbus Lenze i550
0x285C:009 Alarm supression: Entry 9 U32 0x00000000 Fieldbus Lenze i550
0x285C:010 Alarm supression: Entry 10 U32 0x00000000 Fieldbus Lenze i550
0x2860:001 Frequency control: Default setpoint source P201.01 U8 Analog input 1 [2] general Lenze i550