6AG1317-2FK14-2AB0

SIPLUS S7-300 CPU 317F-2PN/DP based on 6ES7317-2FK14-0AB0 with conformal coating, -25…+60 °C, central processing unit with 1.5 MB work memory, 1st interface MPI/DP 12 Mbps, 2nd interface Ethernet PROFINET, with 2-port switch, Micro Memory Card required

Siemens spare part — S7-300 product cancellation (PM410, 1 October 2025); available as a spare part until 2033.

Categorie de produs
CPU
Producător
SIEMENS
Serie de produse
S7-300
General information
Product type designationCPU 317F-2 PN/DP
based on6ES7317-2FK14-0AB0
Product function
Isochronous modeYes; Via PROFIBUS DP or PROFINET interface
Engineering with
Programming packageSTEP 7 V5.5 or higher, Distributed Safety V5.4 SP4
Supply voltage
Rated value (DC)24 V
permissible range, lower limit (DC)20.4 V
permissible range, upper limit (DC)28.8 V
external protection for power supply lines (recommendation)2 A min.
Mains buffering
Mains/voltage failure stored energy time5 ms
Repeat rate, min.1 s
Input current
Current consumption (rated value)750 mA
Current consumption (in no-load operation), typ.150 mA
Inrush current, typ.4 A
I²t1 A²·s
Power loss
Power loss, typ.4.65 W
Storage
Work memory
integrated1 536 kbyte
expandableNo
Load memory
Plug-in (MMC)Yes
Plug-in (MMC), max.8 Mbyte
Data management on MMC (after last programming), min.10 a
Backup
presentYes; Guaranteed by MMC (maintenance-free)
without batteryYes; Program and data
CPU processing times
for bit operations, typ.0.025 µs
for word operations, typ.0.03 µs
for fixed point arithmetic, typ.0.04 µs
for floating point arithmetic, typ.0.16 µs
CPU-blocks
Number of elements (total)2 048; (DBs, FCs, FBs); the maximum number of loadable blocks can be reduced by the MMC used.
DB
Number, max.2 048; Number range: 1 to 16000
Size, max.64 kbyte
FB
Number, max.2 048; Number range: 0 to 7999
Size, max.64 kbyte
FC
Number, max.2 048; Number range: 0 to 7999
Size, max.64 kbyte
OB
Size, max.64 kbyte
Number of free cycle OBs1; OB 1
Number of time alarm OBs1; OB 10
Number of delay alarm OBs2; OB 20, 21
Number of cyclic interrupt OBs4; OB 32, 33, 34, 35
Number of process alarm OBs1; OB 40
Number of DPV1 alarm OBs3; OB 55, 56, 57
Number of isochronous mode OBs1; OB 61 - isochronous mode is possible either on DP or PROFINET IO (not simultaneously)
Number of startup OBs1; OB 100
Number of asynchronous error OBs6; OB 80, 82, 83, 85, 86, 87 (OB83 only for PROFINET IO)
Number of synchronous error OBs2; OB 121, 122
Nesting depth
per priority class16
additional within an error OB4
Counters, timers and their retentivity
S7 counter
Number512
Retentivity
adjustableYes
presetZ 0 to Z 7
Counting range
can be setYes
lower limit0
upper limit999
IEC counter
presentYes
TypeSFB
NumberUnlimited (limited only by RAM capacity)
S7 timer
Number512
Retentivity
adjustableYes
presetNo retentivity
Time range
lower limit10 ms
upper limit9 990 s
IEC timer
presentYes
TypeSFB
NumberUnlimited (limited only by RAM capacity)
Data areas and their retentivity
Retentive data area (incl. timers, counters, flags), max.256 kbyte
Flag
Size, max.4 096 byte
Retentivity availableYes; From MB 0 to MB 4 095
Retentivity presetMB 0 to MB 15
Number of clock memories8; 1 memory byte
Data blocks
Retentivity adjustableYes; via non-retain property on DB
Retentivity presetYes
Local data
per priority class, max.32 768 byte; Max. 2048 bytes per block
Address area
I/O address area
Inputs8 192 byte
Outputs8 192 byte
of which distributed
Inputs8 192 byte
Outputs8 192 byte
Process image
Inputs8 192 byte
Outputs8 192 byte
Inputs, adjustable8 192 byte
Outputs, adjustable8 192 byte
Inputs, default256 byte
Outputs, default256 byte
Subprocess images
Number of subprocess images, max.1; With PROFINET IO, the length of the user data is limited to 1600 bytes
Digital channels
Inputs65 536
of which central1 024
Outputs65 536
of which central1 024
Analog channels
Inputs4 096
of which central256
Outputs4 096
of which central256
Hardware configuration
Number of expansion units, max.3
Number of DP masters
integrated1
via CP4
Number of operable FMs and CPs (recommended)
FM8
CP, PtP8
CP, LAN10
Rack
Racks, max.4
Modules per rack, max.8
Time of day
Clock
Hardware clock (real-time)Yes
retentive and synchronizableYes
Backup time6 wk; At 40 °C ambient temperature
Deviation per day, max.10 s; Typ.: 2 s
Behavior of the clock following POWER-ONClock continues running after POWER OFF
Behavior of the clock following expiry of backup periodthe clock continues at the time of day it had when power was switched off
Operating hours counter
Number4
Number/Number range0 to 3
Range of values0 to 2^31 hours (when using SFC 101)
Granularity1 h
retentiveYes; Must be restarted at each restart
Clock synchronization
supportedYes
to MPI, masterYes
on MPI, deviceYes
to DP, masterYes; With DP slave only slave clock
on DP, deviceYes
in AS, masterYes
in AS, deviceYes
on Ethernet via NTPYes; As client
Digital inputs
Number of digital inputs0
Digital outputs
Number of digital outputs0
Analog inputs
Number of analog inputs0
Interfaces
Number of PROFINET interfaces1
Number of RS 485 interfaces1
Number of RS 422 interfaces0
1. Interface
Interface typeIntegrated RS 485 interface
IsolatedYes
Interface types
RS 485Yes
Output current of the interface, max.200 mA
Protocols
MPIYes
PROFIBUS DP masterYes
PROFIBUS DP deviceYes
Point-to-point connectionNo
MPI
Transmission rate, max.12 Mbit/s
Services
PG/OP communicationYes
RoutingYes
Global data communicationYes
S7 basic communicationYes
S7 communicationYes
S7 communication, as clientNo; but via CP and loadable FB
S7 communication, as serverYes
PROFIBUS DP master
Transmission rate, max.12 Mbit/s
max. number of DP devices124
Services
PG/OP communicationYes
RoutingYes
Global data communicationNo
S7 basic communicationYes; I blocks only
S7 communicationYes
S7 communication, as clientNo
S7 communication, as serverYes
EquidistanceYes
Isochronous modeYes; OB 61; isochronous mode can only be used alternatively on PROFIBUS DP or PROFINET IO
SYNC/FREEZEYes
activation/deactivation of DP devicesYes
max. number of DP devices that can be activated/deactivated at the same time8
Direct data exchange (slave-to-slave communication)Yes; as subscriber
DPV1Yes
Address area
Inputs, max.8 kbyte
Outputs, max.8 kbyte
User data per DP device
Inputs, max.244 byte
Outputs, max.244 byte
PROFIBUS DP device
Transmission rate, max.12 Mbit/s
automatic baud rate searchYes; only with passive interface
Address area, max.32
User data per address area, max.32 byte
Services
PG/OP communicationYes
RoutingYes; Only with active interface
Global data communicationNo
S7 basic communicationNo
S7 communicationYes
S7 communication, as clientNo
S7 communication, as serverYes; Connection configured on one side only
Direct data exchange (slave-to-slave communication)Yes
DPV1No
Transfer memory
Inputs244 byte
Outputs244 byte
2. Interface
Interface typePROFINET
IsolatedYes
automatic detection of transmission rateYes; 10/100 Mbit/s
AutonegotiationYes
AutocrossingYes
Change of IP address at runtime, supportedYes
Interface types
RJ 45 (Ethernet)Yes
Number of ports2
integrated switchYes
Protocols
MPINo
PROFINET IO ControllerYes; Also simultaneously with IO-Device functionality
PROFINET IO DeviceYes; Also simultaneously with IO Controller functionality
PROFINET CBAYes
PROFIBUS DP masterNo
PROFIBUS DP deviceNo
Open IE communicationYes; Via TCP/IP, ISO on TCP, and UDP
Web serverYes
Media redundancyYes
PROFINET IO Controller
Transmission rate, max.100 Mbit/s
Services
PG/OP communicationYes
RoutingYes
S7 communicationYes; with loadable FBs, max. configurable connections: 16, max. number of instances: 32
Isochronous modeYes; OB 61; isochronous mode can only be used alternatively on PROFIBUS DP or PROFINET IO
IRTYes
Shared deviceYes
Prioritized startupYes
Number of IO devices with prioritized startup, max.32
Number of connectable IO Devices, max.128
Of which IO devices with IRT, max.64
of which in line, max.64
Number of IO Devices with IRT and the option "high flexibility"128
of which in line, max.61
Number of connectable IO Devices for RT, max.128
of which in line, max.128
Activation/deactivation of IO DevicesYes
Number of IO Devices that can be simultaneously activated/deactivated, max.8
IO Devices changing during operation (partner ports), supportedYes
Number of IO Devices per tool, max.8
Device replacement without swap mediumYes
Send cycles250 μs, 500 μs,1 ms; 2 ms, 4 ms (not in the case of IRT with "high flexibility" option)
Updating time250 µs to 512 ms (depending on the operating mode, see Manual "S7-300 CPU 31xC and CPU 31x, technical Data" for more details)
Address area
Inputs, max.8 kbyte
Outputs, max.8 kbyte
User data consistency, max.1 024 byte
PROFINET IO Device
Services
PG/OP communicationYes
RoutingYes
S7 communicationYes; with loadable FBs, max. configurable connections: 16, max. number of instances: 32
Isochronous modeNo
IRTYes
PROFIenergyYes; With SFB 73 / 74 prepared for loadable PROFIenergy standard FB for I-Device
Shared deviceYes
Number of IO Controllers with shared device, max.2
Transfer memory
Inputs, max.1 440 byte; Per IO Controller with shared device
Outputs, max.1 440 byte; Per IO Controller with shared device
Submodules
Number, max.64
User data per submodule, max.1 024 byte
PROFINET CBA
acyclic transmissionYes
cyclic transmissionYes
Open IE communication
Number of connections, max.16
Local port numbers used at the system end0, 20, 21, 25, 80, 102, 135, 161, 8080, 34962, 34963, 34964, 65532, 65533, 65534, 65535
Keep-alive function, supportedYes
Protocols
PROFIsafeYes
Redundancy mode
Media redundancy
Switchover time on line break, typ.200 ms; PROFINET MRP
Number of stations in the ring, max.50
Open IE communication
TCP/IPYes; via integrated PROFINET interface and loadable FBs
Number of connections, max.16
Data length for connection type 01H, max.1 460 byte
Data length for connection type 11H, max.32 768 byte
several passive connections per port, supportedYes
ISO-on-TCP (RFC1006)Yes; via integrated PROFINET interface and loadable FBs
Number of connections, max.16
Data length, max.32 768 byte
UDPYes; via integrated PROFINET interface and loadable FBs
Number of connections, max.16
Data length, max.1 472 byte
Web server
supportedYes
User-defined websitesYes
Number of HTTP clients5
Communication functions
PG/OP communicationYes
Data record routingYes
Global data communication
supportedYes
Number of GD loops, max.8
Number of GD packets, max.8
Number of GD packets, transmitter, max.8
Number of GD packets, receiver, max.8
Size of GD packets, max.22 byte
Size of GD packet (of which consistent), max.22 byte
S7 basic communication
supportedYes
User data per job, max.76 byte
User data per job (of which consistent), max.76 byte; 76 bytes (with X_SEND or X_RCV); 64 bytes (with X_PUT or X_GET as server)
S7 communication
supportedYes
as serverYes
as clientYes; via integrated PROFINET interface and loadable FB or via CP and loadable FB
User data per job, max.See online help of STEP 7 (shared parameters of the SFBs/FBs and of the SFCs/FCs of S7 Communication)
S5 compatible communication
supportedYes; via CP and loadable FC
PROFINET CBA (at set setpoint communication load)
Setpoint for the CPU communication load50 %
Number of remote interconnection partners32
number of master/device functions30
total of all master/device connections1 000
data length of all incoming master/device connections, max.4 000 byte
data length of all outgoing master/device connections, max.4 000 byte
Number of device-internal and PROFIBUS interconnections500
Data length of device-internal und PROFIBUS interconnections, max.4 000 byte
Data length per connection, max.1 400 byte
Remote interconnections with cyclic transmission
Transmission frequency: Transmission interval, min.10 ms
Number of incoming interconnections200
Number of outgoing interconnections200
Data length of all incoming interconnections, max.2 000 byte
Data length of all outgoing interconnections, max.2 000 byte
Data length per connection, max.450 byte
HMI variables via PROFINET (acyclic)
Number of stations that can log on for HMI variables (PN OPC/iMap)3; 2x PN OPC/1x iMap
HMI variable updating500 ms
Number of HMI variables200
Data length of all HMI variables, max.2 000 byte
PROFIBUS proxy functionality
supportedYes
Number of linked PROFIBUS devices16
Data length per connection, max.240 byte; Slave-dependent
Number of connections
overall32
usable for PG communication31
reserved for PG communication1
adjustable for PG communication, min.1
adjustable for PG communication, max.31
usable for OP communication31
reserved for OP communication1
adjustable for OP communication, min.1
adjustable for OP communication, max.31
usable for S7 basic communication30
reserved for S7 basic communication0
adjustable for S7 basic communication, min.0
adjustable for S7 basic communication, max.30
usable for S7 communication16
reserved for S7 communication0
adjustable for S7 communication, min.0
adjustable for S7 communication, max.16
total number of instances, max.32
usable for routingX1 as MPI: max. 10; X1 as DP master: max. 24; X1 as DP slave (active): max. 14; X2 as PROFINET: 24 max.
S7 message functions
Number of login stations for message functions, max.32; Depending on the configured connections for PG/OP and S7 basic communication
Process diagnostic messagesYes
simultaneously active Alarm_S blocks, max.300
Test commissioning functions
Status blockYes; Up to 2 simultaneously
Single stepYes
Number of breakpoints4
Status/control
Status/control variableYes
VariablesInputs, outputs, memory bits, DB, times, counters
Number of variables, max.30
of which status variables, max.30
of which control variables, max.14
Forcing
ForcingYes
Forcing, variablesInputs, outputs
Number of variables, max.10
Diagnostic buffer
presentYes
Number of entries, max.500
can be setNo
of which powerfail-proof100; Only the last 100 entries are retained
Number of entries readable in RUN, max.499
can be setYes; From 10 to 499
preset10
Service data
Can be read outYes
Standards, approvals, certificates
CE markYes
UL approvalYes; File E239877
RCM (formerly C-TICK)Yes
KC approvalYes
EAC (formerly Gost-R)Yes
Use in hazardous areas
ATEX markingYes
Railway application
EN 50155No
Ambient conditions
Ambient temperature during operation
min.-25 °C; = Tmin
max.60 °C; = Tmax
Ambient temperature during storage/transportation
min.-40 °C
max.70 °C
Altitude during operation relating to sea level
Installation altitude above sea level, max.2 000 m
Ambient air temperature-barometric pressure-altitudeTmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m)
Relative humidity
With condensation, tested in accordance with IEC 60068-2-38, max.100 %; RH incl. condensation/frost (no commissioning under condensation conditions)
Resistance
Use in stationary industrial systems
to biologically active substances according to EN 60721-3-3Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request
to chemically active substances according to EN 60721-3-3Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); *
to mechanically active substances according to EN 60721-3-3Yes; Class 3S4 incl. sand, dust, *
Use on ships/at sea
to biologically active substances according to EN 60721-3-6Yes; Class 6B2 mold and fungal spores (excluding fauna); Class 6B3 on request
to chemically active substances according to EN 60721-3-6Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); *
to mechanically active substances according to EN 60721-3-6Yes; Class 6S3 incl. sand, dust; *
Usage in industrial process technology
Against chemically active substances acc. to EN 60654-4Yes; Class 3 (excluding trichlorethylene)
Environmental conditions for process, measuring and control systems acc. to ANSI/ISA-71.04Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil)
Remark
Note regarding classification of environmental conditions acc. to EN 60721, EN 60654-4 and ANSI/ISA-71.04* The supplied plug covers must remain in place over the unused interfaces during operation!
Configuration
Configuration software
STEP 7Yes; V5.5 or higher
Programming
Command setsee instruction list
Nesting levels8
System functions (SFC)see instruction list
System function blocks (SFB)see instruction list
Programming language
LADYes
FBDYes
STLYes
SCLYes
CFCYes
GRAPHYes
HiGraph®Yes
Know-how protection
User program protection/password protectionYes
Block encryptionYes; With S7 block Privacy
Dimensions
Width40 mm
Height125 mm
Depth130 mm
Weights
Weight, approx.340 g
Approvals / Certificates