6AG1331-7KB02-2AB0

SIPLUS S7-300 SM 331 2 AI 20-pole based on 6ES7331-7KB02-0AB0 with conformal coating, -25…+70 °C, analog input isolated 2 AI, resolution 9/12/14 bits, U/I/thermocouple/resistor, alarm, diagnostics, 1x 20-pole, removing/inserting with active backplane bus

Siemens spare part — S7-300 product cancellation (PM410, 1 October 2025); available as a spare part until 2033.

Categorie de produs
Module analogice
Producător
SIEMENS
Serie de produse
S7-300
General information
based on6ES7331-7KB02-0AB0
Product function
Isochronous modeNo
Supply voltage
Load voltage L+
Rated value (DC)24 V
Reverse polarity protectionYes
Input current
from load voltage L+ (without load), max.80 mA
from backplane bus 5 V DC, max.50 mA
Power loss
Power loss, typ.1.3 W
Analog inputs
Number of analog inputs2
For resistance measurement1
permissible input voltage for voltage input (destruction limit), max.20 V; continuous; 75 V for max. 1 s (mark to space ratio 1:20)
permissible input current for current input (destruction limit), max.40 mA
Constant measurement current for resistance-type transmitter, typ.1.67 mA
Input ranges
VoltageYes
CurrentYes
ThermocoupleYes
Resistance thermometerYes
ResistanceYes
Input ranges (rated values), voltages
0 to +10 VNo
1 V to 5 VYes
Input resistance (1 V to 5 V)100 kΩ
1 V to 10 VNo
-1 V to +1 VYes
Input resistance (-1 V to +1 V)10 MΩ
-10 V to +10 VYes
Input resistance (-10 V to +10 V)100 kΩ
-2.5 V to +2.5 VYes
Input resistance (-2.5 V to +2.5 V)100 kΩ
-250 mV to +250 mVYes
Input resistance (-250 mV to +250 mV)10 MΩ
-5 V to +5 VYes
Input resistance (-5 V to +5 V)100 kΩ
-50 mV to +50 mVNo
-500 mV to +500 mVYes
Input resistance (-500 mV to +500 mV)10 MΩ
-80 mV to +80 mVYes
Input resistance (-80 mV to +80 mV)10 MΩ
Input ranges (rated values), currents
0 to 20 mAYes
Input resistance (0 to 20 mA)25 Ω
-10 mA to +10 mAYes
Input resistance (-10 mA to +10 mA)25 Ω
-20 mA to +20 mAYes
Input resistance (-20 mA to +20 mA)25 Ω
-3.2 mA to +3.2 mAYes
Input resistance (-3.2 mA to +3.2 mA)25 Ω
4 mA to 20 mAYes
Input resistance (4 mA to 20 mA)25 Ω
Input ranges (rated values), thermocouples
Type EYes
Input resistance (Type E)10 MΩ
Type JYes
Input resistance (type J)10 MΩ
Type KYes
Input resistance (Type K)10 MΩ
Type LNo
Type NYes
Input resistance (Type N)10 MΩ
Type RNo
Type SNo
Type TNo
Type UNo
Type TXK/TXK(L) to GOSTNo
Input ranges (rated values), resistance thermometer
Cu 10No
Ni 100Yes
Input resistance (Ni 100)10 MΩ; Standard
Pt 100Yes
Input resistance (Pt 100)10 kΩ; Standard
Input ranges (rated values), resistors
0 to 150 ohmsYes
Input resistance (0 to 150 ohms)10 MΩ
0 to 300 ohmsYes
Input resistance (0 to 300 ohms)10 MΩ
0 to 600 ohmsYes
Input resistance (0 to 600 ohms)10 MΩ
0 to 6000 ohmsNo
Thermocouple (TC)
Temperature compensation
ParameterizableYes
internal temperature compensationYes
external temperature compensation with compensations socketYes
for definable comparison point temperatureYes
Characteristic linearization
ParameterizableYes
for thermocouplesType E, J, K, L, N
for resistance thermometerPt100 (standard, climatic range), Ni100 (standard, climatic range)
Cable length
shielded, max.200 m; 50 m at 80 mV and thermocouples
Analog value generation for the inputs
Integration and conversion time/resolution per channel
Resolution with overrange (bit including sign), max.15 bit; Unipolar: 9/12/12/14 bit; bipolar: 9 bit + sign/12 bit + sign/12 bit + sign/14 bit + sign
Integration time, parameterizableYes; 2,5 / 16,67 / 20 / 100 ms
Interference voltage suppression for interference frequency f1 in Hz400 / 60 / 50 / 10 Hz
Encoder
Connection of signal encoders
for voltage measurementYes
for current measurement as 2-wire transducerYes
for current measurement as 4-wire transducerYes
for resistance measurement with two-wire connectionYes
for resistance measurement with three-wire connectionYes
for resistance measurement with four-wire connectionYes
Errors/accuracies
Operational error limit in overall temperature range
Voltage, relative to input range, (+/-)1 %; ±1% (80 mV); ±0.6% (250 mV to 1 000 mV); ±0.8% (2.5 V to 10 V) @ 0 ... +60 °C; ±1.3% (80 mV); ±0.8% (250 mV to 1 000 mV); ±1% (2.5 V to 10 V) @ -25 ... +70 °C
Current, relative to input range, (+/-)0.7 %; @ 0 ... +60 °C; ±0.9% @ -25 ... +70 °C; from 3.2 mA to 20 mA
Resistance, relative to input range, (+/-)0.7 %; @ 0 ... +60 °C; ±0.9% @ -25 ... +70 °C; 150, 300, 600 ohm
Resistance thermometer, relative to input range, (+/-)0.7 %; ±0.7 % (Pt100 / Ni100); ±0.8 % (Pt100 climate) @ 0 ... +60 °C; ±0.9 % (Pt100 / Ni100); ±1 % (Pt100 climate) @ -25 ... +70 °C
Thermocouple, relative to input range, (+/-)1.1 %; @ 0 ... +60 °C; 1.3% @ -25 ... +70 °C; type E, J, K, L, N
Basic error limit (operational limit at 25 °C)
Voltage, relative to input range, (+/-)0.6 %; ±0.6% (80 mV, 2.5 V to 10 V); ±0.4% (250 mV to 1 000 mV)
Current, relative to input range, (+/-)0.5 %; 3.2 to 20 mA
Resistance, relative to input range, (+/-)0.5 %; 150, 300, 600 Ohm
Resistance thermometer, relative to input range, (+/-)0.6 %; ±0.5% (Pt100/ Ni100), ±0.6% (Pt100 climate)
Thermocouple, relative to input range, (+/-)0.7 %; Type E, N, J, K, L
Interrupts/diagnostics/status information
Diagnostics functionYes; Parameterizable
Alarms
Diagnostic alarmYes
Limit value alarmYes; Parameterizable, channel 0
Diagnoses
Diagnostic information readableYes
Diagnostics indication LED
Group error SF (red)Yes
Potential separation
Potential separation analog inputs
between the channelsNo
between the channels and backplane busYes
between the channels and the power supply of the electronicsYes; Not for 2-wire transmitters
Isolation
Isolation tested with500 V DC
Standards, approvals, certificates
CE markYes
UL approvalYes; File E239877
RCM (formerly C-TICK)Yes
KC approvalYes
EAC (formerly Gost-R)Yes
Railway application
EN 50121-4No
EN 50155No
Ambient conditions
Ambient temperature during operation
min.-25 °C; = Tmin
max.70 °C; = Tmax; 60 °C @ UL/cUL, ATEX and FM use
Ambient temperature during storage/transportation
min.-40 °C
max.70 °C
Altitude during operation relating to sea level
Installation altitude above sea level, max.5 000 m
Ambient air temperature-barometric pressure-altitudeTmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m)
Relative humidity
With condensation, tested in accordance with IEC 60068-2-38, max.100 %; RH incl. condensation/frost (no commissioning under condensation conditions)
Resistance
Use in stationary industrial systems
to biologically active substances according to EN 60721-3-3Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request
to chemically active substances according to EN 60721-3-3Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); *
to mechanically active substances according to EN 60721-3-3Yes; Class 3S4 incl. sand, dust, *
Use on ships/at sea
to biologically active substances according to EN 60721-3-6Yes; Class 6B2 mold and fungal spores (excluding fauna); Class 6B3 on request
to chemically active substances according to EN 60721-3-6Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); *
to mechanically active substances according to EN 60721-3-6Yes; Class 6S3 incl. sand, dust; *
Usage in industrial process technology
Against chemically active substances acc. to EN 60654-4Yes; Class 3 (excluding trichlorethylene)
Environmental conditions for process, measuring and control systems acc. to ANSI/ISA-71.04Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil)
Remark
Note regarding classification of environmental conditions acc. to EN 60721, EN 60654-4 and ANSI/ISA-71.04* The supplied plug covers must remain in place over the unused interfaces during operation!
Connection method
required front connector20-pin
Dimensions
Width40 mm
Height125 mm
Depth120 mm
Weights
Weight, approx.250 g