6ES7517-3HP00-0AB0
SIMATIC S7-1500H, CPU 1517H-3 PN, unitate centrală de procesare cu memorie de lucru de 2 MB pentru program și 8 MB pentru date, interfața 1: PROFINET RT cu switch cu 2 porturi, interfața 2: PROFINET, interfața 3/4: H-SYNC, necesită SIMATIC Memory Card.
Categorie de produs
CPUProducător
SIEMENSSerie de produse
S7-1500| General information | |
|---|---|
| Product type designation | CPU 1517H-3 PN |
| HW functional status | FS06 |
| Firmware version | V3.1 |
| FW update possible | Yes |
| Product function | |
| I&M data | Yes; I&M0 to I&M3 |
| Isochronous mode | No |
| SysLog | Yes |
| Engineering with | |
| STEP 7 TIA Portal configurable/integrated from version | V19 (FW V3.1) / V15.1 (FW V2.6) or higher |
| Display | |
| Screen diagonal [cm] | 6.1 cm |
| Control elements | |
| Number of keys | 6 |
| Mode selector switch | 1 |
| Supply voltage | |
| Rated value (DC) | 24 V |
| permissible range, lower limit (DC) | 19.2 V |
| permissible range, upper limit (DC) | 28.8 V |
| Reverse polarity protection | Yes |
| Mains buffering | |
| Mains/voltage failure stored energy time | 5 ms |
| Repeat rate, min. | 1/s |
| Input current | |
| Current consumption (rated value) | 1.5 A |
| Current consumption, max. | 1.9 A |
| Inrush current, max. | 1.9 A; Rated value |
| I²t | 0.4 A²·s |
| Power | |
| Infeed power to the backplane bus | 12 W |
| Power consumption from the backplane bus (balanced) | 30 W |
| Power loss | |
| Power loss, typ. | 24 W |
| Storage | |
| Number of slots for SIMATIC memory card | 1 |
| SIMATIC memory card required | Yes |
| Work memory | |
| integrated (for program) | 2 Mbyte |
| integrated (for data) | 8 Mbyte |
| Load memory | |
| Plug-in (SIMATIC Memory Card), max. | 32 Gbyte |
| Backup | |
| maintenance-free | Yes |
| CPU processing times | |
| for bit operations, typ. | 4 ns |
| for word operations, typ. | 6 ns |
| for fixed point arithmetic, typ. | 6 ns |
| for floating point arithmetic, typ. | 24 ns |
| CPU-blocks | |
| Number of elements (total) | 12 000; Blocks (OB, FB, FC, DB) and UDTs |
| DB | |
| Number range | Number range: 1 to 59 999 |
| Size, max. | 8 Mbyte; For non-optimized block accesses, the max. size of the DB is 64 KB |
| FB | |
| Number range | 0 ... 65 535 |
| Size, max. | 1 Mbyte |
| FC | |
| Number range | 0 ... 65 535 |
| Size, max. | 1 Mbyte |
| OB | |
| Size, max. | 1 Mbyte |
| Number of free cycle OBs | 100 |
| Number of time alarm OBs | 20 |
| Number of delay alarm OBs | 20 |
| Number of cyclic interrupt OBs | 20; with minimum OB 3x cycle of 1 ms |
| Number of process alarm OBs | 50 |
| Number of DPV1 alarm OBs | 3 |
| Number of startup OBs | 100 |
| Number of asynchronous error OBs | 4 |
| Number of synchronous error OBs | 2 |
| Number of diagnostic alarm OBs | 1 |
| Nesting depth | |
| per priority class | 24 |
| Counters, timers and their retentivity | |
| S7 counter | |
| Number | 2 048 |
| Retentivity | |
| adjustable | Yes |
| IEC counter | |
| Number | Any (only limited by the main memory) |
| Retentivity | |
| adjustable | Yes |
| S7 timer | |
| Number | 2 048 |
| Retentivity | |
| adjustable | Yes |
| IEC timer | |
| Number | Any (only limited by the main memory) |
| Retentivity | |
| can be set | Yes |
| Data areas and their retentivity | |
| Retentive data area (incl. timers, counters, flags), max. | 768 kbyte; In total; available retentive memory for bit memories, timers, counters, DBs, and technology data (axes): 700 KB |
| Flag | |
| Size, max. | 16 kbyte |
| Number of clock memories | 8; 8 clock memory bit, grouped into one clock memory byte |
| Data blocks | |
| Retentivity adjustable | Yes |
| Retentivity preset | No |
| Local data | |
| per priority class, max. | 64 kbyte; max. 16 KB per block |
| Address area | |
| Number of IO modules | 8 192; max. number of modules / submodules |
| I/O address area | |
| Inputs | 32 kbyte; All inputs are in the process image |
| Outputs | 32 kbyte; All outputs are in the process image |
| per integrated IO subsystem | |
| Inputs (volume) | 16 kbyte |
| Outputs (volume) | 16 kbyte |
| Subprocess images | |
| Number of subprocess images, max. | 31 |
| Hardware configuration | |
| Number of distributed IO systems | 64; A distributed I/O system is characterized not only by the integration of distributed I/O via PROFINET, but also by the connection of I/O via IE/PB-Links. |
| Number of IO Controllers | |
| Integrated | 1 |
| Rack | |
| Modules per rack, max. | 9; CPU + 2 PS + 6 CP |
| Time of day | |
| Clock | |
| Type | Hardware clock |
| Backup time | 6 wk; At 40 °C ambient temperature, typically |
| Deviation per day, max. | 10 s; Typ.: 2 s |
| Operating hours counter | |
| Number | 16 |
| Clock synchronization | |
| supported | Yes |
| on Ethernet via NTP | Yes |
| Interfaces | |
| Number of PROFINET interfaces | 2 |
| 1. Interface | |
| Interface types | |
| RJ 45 (Ethernet) | Yes; X1 |
| Number of ports | 2 |
| integrated switch | Yes |
| Protocols | |
| IP protocol | Yes; IPv4 |
| PROFINET IO Controller | Yes |
| PROFINET IO device | No |
| SIMATIC communication | Yes; Only Server |
| Open IE communication | Yes; Optionally also encrypted |
| Web server | Yes |
| Media redundancy | Yes |
| PROFINET IO Controller | |
| Services | |
| Isochronous mode | No |
| IRT | No |
| Dynamic Frame Packing (DFP) | Yes |
| PROFIenergy | Yes; per user program |
| Prioritized startup | No |
| Number of connectable IO Devices, max. | 256 |
| Updating times | The minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data |
| PROFINET Security Class | 1 |
| Update time for RT | |
| for send cycle of 1 ms | 1 ms to 512 ms |
| 2. Interface | |
| Interface types | |
| RJ 45 (Ethernet) | Yes; X2 |
| Number of ports | 1 |
| integrated switch | No |
| Protocols | |
| IP protocol | Yes; IPv4 |
| PROFINET IO Controller | No |
| PROFINET IO Device | No |
| SIMATIC communication | Yes; Only Server |
| Open IE communication | Yes; Optionally also encrypted |
| Web server | Yes |
| Media redundancy | No |
| 3. Interface | |
| Interface type | Pluggable synchronization submodule (FO) |
| Plug-in interface modules | Synchronization module 6ES7960-1CB00-0AA5, 6ES7960-1FB00-0AA5 or 6ES7 960-1FE00-0AA5 |
| 4. Interface | |
| Interface type | Pluggable synchronization submodule (FO) |
| Plug-in interface modules | Synchronization module 6ES7960-1CB00-0AA5, 6ES7960-1FB00-0AA5 or 6ES7960-1FE00-0AA5 |
| Interface types | |
| RJ 45 (Ethernet) | |
| 100 Mbps | Yes |
| Autonegotiation | Yes |
| Autocrossing | Yes |
| Industrial Ethernet status LED | Yes |
| Protocols | |
| PROFIsafe | No |
| Number of connections | |
| Number of connections, max. | 320; via integrated interfaces of the CPU and connected CPs |
| Number of connections reserved for ES/HMI/web | 10 |
| Number of connections via integrated interfaces | 288 |
| Number of S7 routing paths | 64 |
| Redundancy mode | |
| PROFINET system redundancy (S2) | Yes |
| PROFINET system redundancy (R1) | Yes |
| Media redundancy | |
| MRP | Yes; MRP Automanager according to IEC 62439-2 Edition 2.0 |
| MRP interconnection, supported | Yes; as MRP ring node according to IEC 62439-2 Edition 3.0 |
| MRPD | No |
| Switchover time on line break, typ. | 200 ms; PROFINET MRP |
| Number of stations in the ring, max. | 50 |
| SIMATIC communication | |
| PG/OP communication | Yes; encryption with TLS V1.3 pre-selected |
| S7 routing | Yes |
| S7 communication, as server | Yes |
| S7 communication, as client | No |
| Open IE communication | |
| TCP/IP | Yes |
| Data length, max. | 64 kbyte |
| several passive connections per port, supported | Yes |
| ISO-on-TCP (RFC1006) | Yes |
| Data length, max. | 64 kbyte |
| UDP | Yes |
| Data length, max. | 2 kbyte; 1 472 bytes for UDP broadcast |
| UDP multicast | Yes; 128 multicast circuits (of which max. 5 via X1) |
| DHCP | No |
| DNS | Yes |
| SNMP | Yes |
| DCP | Yes |
| LLDP | Yes |
| Encryption | Yes; Optional |
| Web server | |
| HTTP | No |
| HTTPS | Yes; only via Web API |
| web API | Yes |
| Number of sessions, max. | 200 |
| number of simultaneous HTTP calls, max. | 4 |
| HTTP request body, max. | 131 072 byte |
| OPC UA | |
| Runtime license required | Yes; "Large" license required per CPU |
| OPC UA Client | No |
| OPC UA Server | Yes; Data access (read, write, subscribe), method call, custom address space |
| Application authentication | Yes |
| Security policies | available security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256, Aes128Sha256RsaOaep, Aes256Sha256RsaPss |
| User authentication | "anonymous" or by user name & password |
| GDS support (certificate management) | No |
| Number of sessions, max. | 32 |
| Number of subscriptions per session, max. | 25 |
| Sampling interval, min. | 25 ms |
| Publishing interval, min. | 25 ms |
| Number of server methods, max. | 100 |
| Number of inputs/outputs per server method, max. | 20 |
| Number of monitored items, recommended max. | 5 000; for 1 s sampling interval and 1 s send interval |
| Number of server interfaces, max. | 10 of each "Server interfaces" / "Companion specification" type and 20 of the type "Reference namespace" |
| Number of nodes for user-defined server interfaces, max. | 30 000 |
| Alarms and Conditions | No |
| Further protocols | |
| MODBUS | Yes; MODBUS TCP |
| S7 message functions | |
| Number of login stations for message functions, max. | 64 |
| number of subscriptions, max. | 750 |
| number of tags/attributes for subscriptions, max. | 20 000 |
| Program alarms | Yes |
| Number of configurable program messages, max. | 10 000; Program messages are generated by the "Program_Alarm" block, ProDiag or GRAPH |
| Number of loadable program messages in RUN, max. | 10 000 |
| Number of simultaneously active program alarms | |
| Number of program alarms | 2 000 |
| Number of alarms for system diagnostics | 1 000 |
| Test commissioning functions | |
| Joint commission (Team Engineering) | No |
| Status block | Yes; Up to 16 simultaneously |
| Single step | No |
| Number of breakpoints | 20; Breakpoints are only supported in RUN-Solo status |
| Status/control | |
| Status/control variable | Yes |
| Variables | Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters |
| Number of variables, max. | |
| of which status variables, max. | 200; per job |
| of which control variables, max. | 200; per job |
| Forcing | |
| Forcing | Yes |
| Forcing, variables | Peripheral inputs/outputs |
| Number of variables, max. | 200 |
| Diagnostic buffer | |
| present | Yes |
| Number of entries, max. | 3 200 |
| of which powerfail-proof | 1 000 |
| Traces | |
| Number of configurable Traces | 8 |
| Memory size per trace, max. | 512 kbyte |
| Interrupts/diagnostics/status information | |
| Diagnostics indication LED | |
| RUN/STOP LED | Yes |
| ERROR LED | Yes |
| MAINT LED | Yes |
| Connection display LINK TX/RX | Yes |
| Supported technology objects | |
| Motion Control | No |
| Controller | |
| PID_Compact | Yes; Universal PID controller with integrated optimization |
| PID_3Step | Yes; PID controller with integrated optimization for valves |
| PID-Temp | Yes; PID controller with integrated optimization for temperature |
| Counting and measuring | Yes |
| Standards, approvals, certificates | |
| Ecological footprint | |
| environmental product declaration | Yes |
| Global warming potential | |
| global warming potential, (total) [CO2 eq] | 570 kg |
| global warming potential, (during production) [CO2 eq] | 96.9 kg |
| global warming potential, (during operation) [CO2 eq] | 483 kg |
| global warming potential, (after end of life cycle) [CO2 eq] | -9.97 kg |
| Security | |
| PROFINET Security Class | 1 |
| Ambient conditions | |
| Ambient temperature during operation | |
| horizontal installation, min. | 0 °C |
| horizontal installation, max. | 60 °C; Display: 50 °C, at an operating temperature of typically 50 °C, the display is switched off |
| vertical installation, min. | 0 °C |
| vertical installation, max. | 40 °C; Display: 40 °C, at an operating temperature of typically 40 °C, the display is switched off |
| Ambient temperature during storage/transportation | |
| min. | -40 °C |
| max. | 70 °C |
| Altitude during operation relating to sea level | |
| Installation altitude above sea level, max. | 5 000 m; Restrictions for installation altitudes > 2 000 m, see manual |
| Configuration | |
| Programming | |
| Programming language | |
| LAD | Yes |
| FBD | Yes |
| STL | Yes |
| SCL | Yes |
| CFC | Yes |
| GRAPH | Yes |
| Know-how protection | |
| User program protection/password protection | Yes |
| Copy protection | No |
| Block protection | Yes |
| Access protection | |
| protection of confidential configuration data | Yes |
| Password for display | Yes |
| Protection level: Write protection | Yes |
| Protection level: Read/write protection | Yes |
| Protection level: Write protection for Failsafe | No |
| Protection level: Complete protection | Yes |
| User administration | Yes |
| Cycle time monitoring | |
| lower limit | adjustable minimum cycle time |
| upper limit | adjustable maximum cycle time |
| Dimensions | |
| Width | 210 mm |
| Height | 147 mm |
| Depth | 129 mm |
| Weights | |
| Weight, approx. | 2 094 g; Interface modules: 2x 18 g |
| Approvals / Certificates | |