i950
- Rated power 0.37 kW/0.5 HP
- Output current 2.4 A
- Output frequency 0-599 Hz
- Rated mains voltage 1/N(3)/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 0.55 kW/0.75 HP
- Output current 3.2 A
- Output frequency 0-599 Hz
- Rated mains voltage 1/N(3)/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 0.55 kW/0.75 HP
- Output current 1.8/1.6 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 0.75 kW/1 HP
- Output current 4.2 A
- Output frequency 0-599 Hz
- Rated mains voltage 1/N(3)/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 0.75 kW/1 HP
- Output current 2.4/2.1 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 1.5 kW/2 HP
- Output current 7 A
- Output frequency 0-599 Hz
- Rated mains voltage 1/N(3)/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 2.2 kW/3 HP
- Output current 9.6 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 2.2 kW/3 HP
- Output current 5.6/4.8 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 4 kW/5 HP
- Output current 16.5 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 4 kW/5 HP
- Output current 9.5/8.2 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 5.5 kW/7.5 HP
- Output current 23 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 7.5 kW/10 HP
- Output current 16.5/14 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 11 kW/15 HP
- Output current 23.5/21 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 15 kW/20 HP
- Output current 32/27 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 22 kW/30 HP
- Output current 47/40.4 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 30 kW/40 HP
- Output current 61/52 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 45 kW/60 HP
- Output current 89/77 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 55 kW/75 HP
- Output current 110/96 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 75 kW/100 HP
- Output current 150/124 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 90 kW/125 HP
- Output current 180/156 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 110 kW/150 HP
- Output current 212/180 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
-
Fault message ID
704708510 0x2A00FF9E Description
CausePDSS - Creep velocity SCS exceeded
RemedyThe drive has exceeded the currently permitted SCS creeping speed.
Severity/responseCheck parameters for PDSS. Reduce speeds in the application. Increase distance to PDSS limit values.
Warning
-
Fault message ID
704708511 0x2A00FF9F Description
CausePDSS - No diagnostic mark detected
RemedyNo diagnostic marker for PDSS was detected.
Severity/responseAdapt parameters for the diagnostic marker. Check the function of the diagnostic sensors. Correct position of the diagnostic sensors.
Warning
-
Fault message ID
704708512 0x2A00FFA0 Description
CausePDSS - Diagnostic mark detected at invalid position
RemedyA diagnostic marker for PDSS was detected at an invalid position.
Severity/responseAdapt parameters for the diagnostic marker. Correct position of the diagnostic sensors.
Warning
-
Fault message ID
704708518 0x2A00FFA6 Description
CauseSHom - Time-out
RemedyAfter SHom_Start, the home position was not detected within the timeout set in 0x2882:002.
Severity/responseAdapt timeout. Check configuration of triggers for SHom_Start and SHom_Load.
Warning
-
Fault message ID
704708519 0x2A00FFA7 Description
CauseSHom - Home position deleted
RemedyThe home position was deleted by acknowledging a position error or manually via 0x2114:014.
Severity/responseExecute SHom again.
Information
-
Fault message ID
704708520 0x2A00FFA8 Description
CauseSHom - Maximum slip value exceeded
RemedyThe maximum permissible slip has been exceeded.
Severity/responseEvaluate slip monitoring in 0x2870:2. Check the wear-prone drive components and replace then if necessary.
Warning
-
Fault message ID
704708521 0x2A00FFA9 Description
CauseSHom - Tolerance of start position exceeded
RemedyThe tolerance for the starting position has been exceeded.
Severity/responseDo not move drive components while the mains voltage is switched off. Execute SHom again.
Warning
-
Fault message ID
704708522 0x2A00FFAA Description
CauseSHom - Tolerance of position comparison exceeded
RemedyThe tolerance for the position comparison has been exceeded.
Severity/responseCheck gearbox factor and mounting direction. Check the wear-prone drive components and replace then if necessary. Execute SHom again.
Warning
-
Fault message ID
704708523 0x2A00FFAB Description
CauseSSM - Invalid safe velocity
RemedyNo safe speed could be determined. The encoder is not initialized or the status transmitted by the encoder is invalid.
Severity/responseCheck encoder. A certified motor/encoder combination must be used.
Warning
-
Fault message ID
704708524 0x2A00FFAC Description
CauseSSM - Encoder error
RemedyThe monitoring of the safe speed via encoder is faulty.
Severity/responseCheck encoder. Check configuration of the encoder.
Warning
-
Fault message ID
704708525 0x2A00FFAD Description
CauseSSM - Resolver error
RemedyThe monitoring of the safe speed via resolver is faulty.
Severity/responseCheck encoder. Check configuration of the encoder.
Warning
-
Fault message ID
704708526 0x2A00FFAE Description
CauseSSM - Error in standard device data
RemedySafe speed monitoring is faulty because the device is transmitting incorrect data.
Severity/responseCheck encoder. Check configuration of the encoder.
Warning
-
Fault message ID
704708527 0x2A00FFAF Description
CauseSSM - Speed deviation too high
RemedyThe difference between the internally calculated speed and the speed transmitted by the encoder is too large.
Severity/responseCheck configuration of the encoder. Check gearbox factor. Check tolerance for the deviation.
Warning
-
Fault message ID
704708528 0x2A00FFB0 Description
CauseSSM - Synchronization error
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
Fault message ID
704708529 0x2A00FFB1 Description
CauseMUT - Muting function active
RemedyMUT - Muting function active
Severity/responseFor information only. No remedy necessary.
Information
-
Fault message ID
704708530 0x2A00FFB2 Description
CauseMUT - Muting function completed
RemedyMUT - Muting function completed
Severity/responseFor information only. No remedy necessary.
Information
-
Fault message ID
704708531 0x2A00FFB3 Description
CauseMUT - Muting function aborted
RemedyCommunication error. The muting function was canceled.
Severity/responseReconnect to the device. Restart the muting function.
Information
-
Fault message ID
704708536 0x2A00FFB8 Description
CauseHDSL encoder - ID was set
RemedyThe encoder ID of the connected HIPERFACE DSL® encoder has been set to the correct value. The error Different encoder ID has been fixed. The status bit has been reset: 0x2878:050, bit 13
Severity/responseCheck whether the encoder-axis assignment is now correct.
Information
-
Fault message ID
805306384 0x30000010 Description
CauseInternal error
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
Fault message ID
805306385 0x30000011 Description
CauseInternal error
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
Fault message ID
805306386 0x30000012 Description
CauseInternal error
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
Fault message ID
805306387 0x30000013 Description
CauseInternal error
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
Fault message ID
805306570 0x300000CA Description
CauseInternal error
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
Fault message ID
805306571 0x300000CB Description
CauseInternal error
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
Fault message ID
805311368 0x30001388 Description
CauseInternal error
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
0x60B2
Parameter
Offset torque Data type
I16 Default setting
0.0 % Attributes
- -
0x60B8
Parameter
Touch probe settings Data type
U16 Default setting
0x0000 Attributes
H -
0x60B9
Parameter
Touch probe status Data type
U16 Default setting
- (Read only) Attributes
H -
0x60BA
Parameter
Touch probe 1: Position at pos. edge Data type
I32 Default setting
- (Read only) Attributes
- -
0x60BB
Parameter
Touch probe 1: Position at neg. edge Data type
I32 Default setting
- (Read only) Attributes
- -
0x60BC
Parameter
Touch probe 2: Position at pos. edge Data type
I32 Default setting
- (Read only) Attributes
- -
0x60BD
Parameter
Touch probe 2: Position at neg. edge Data type
I32 Default setting
- (Read only) Attributes
- -
0x60C0
Parameter
Interpolation mode Data type
I16 Default setting
Quadratic [-1] Attributes
- -
0x60C2:001
Parameter
Interpolation time: Interpolation time mantissa Data type
U8 Default setting
1 Attributes
- -
0x60C2:002
Parameter
Interpolation time: Interpolation time exponent Data type
I8 Default setting
-3 Attributes
- -
0x60E0
Parameter
Positive torque limit Data type
U16 Default setting
100.0 % Attributes
- -
0x60E1
Parameter
Negative torque limit Data type
U16 Default setting
100.0 % Attributes
- -
0x60E4:001
Parameter
Additional position actual value: Load encoder/ master encoder - actual position Data type
I32 Default setting
- (Read only) Attributes
- -
0x60E5:001
Parameter
Additional velocity actual value: Load encoder/ master encoder - actual speed Data type
I32 Default setting
rpm (Read only) Attributes
- -
0x60E6:001
Parameter
Additional position encoder resolution - encoder increments: Load encoder/master encoder - number of increments Data type
U32 Default setting
16 Bit [65536] Attributes
C -
0x60EB:001
Parameter
Additional position encoder resolution - motor revolutions: Load encoder/master encoder - resolution of motor revolutions Data type
U32 Default setting
1 Attributes
C -
0x60F4
Parameter
Following error actual value Data type
I32 Default setting
- (Read only) Attributes
- -
0x60FA
Parameter
Control effort Data type
I32 Default setting
rpm (Read only) Attributes
- -
0x60FC
Parameter
Position demand internal value Data type
I32 Default setting
- (Read only) Attributes
- -
0x60FD
Parameter
Digital input status Data type
U32 Default setting
- (Read only) Attributes
H -
0x60FE:001
Parameter
Digital outputs: Digital output status Data type
U32 Default setting
0x00000000 Attributes
H -
0x60FF
Parameter
Set speed Data type
I32 Default setting
0.00 rpm Attributes
- -
0x6404
Parameter
Motor manufacturer Data type
STRING[50] Default setting
"Lenze" Attributes
- -
0x6502
Parameter
Supported drive modes Data type
U32 Default setting
- (Read only) Attributes
H -
0x67FF
Parameter
Device profile number Data type
U32 Default setting
- (Read only) Attributes
-
No results.