i950
- Rated power 0.37 kW/0.5 HP
- Output current 2.4 A
- Output frequency 0-599 Hz
- Rated mains voltage 1/N(3)/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 0.55 kW/0.75 HP
- Output current 3.2 A
- Output frequency 0-599 Hz
- Rated mains voltage 1/N(3)/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 0.55 kW/0.75 HP
- Output current 1.8/1.6 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 0.75 kW/1 HP
- Output current 4.2 A
- Output frequency 0-599 Hz
- Rated mains voltage 1/N(3)/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 0.75 kW/1 HP
- Output current 2.4/2.1 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 1.5 kW/2 HP
- Output current 7 A
- Output frequency 0-599 Hz
- Rated mains voltage 1/N(3)/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 2.2 kW/3 HP
- Output current 9.6 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 2.2 kW/3 HP
- Output current 5.6/4.8 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 4 kW/5 HP
- Output current 16.5 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 4 kW/5 HP
- Output current 9.5/8.2 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 5.5 kW/7.5 HP
- Output current 23 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 7.5 kW/10 HP
- Output current 16.5/14 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 11 kW/15 HP
- Output current 23.5/21 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 15 kW/20 HP
- Output current 32/27 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 22 kW/30 HP
- Output current 47/40.4 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 30 kW/40 HP
- Output current 61/52 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 45 kW/60 HP
- Output current 89/77 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 55 kW/75 HP
- Output current 110/96 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 75 kW/100 HP
- Output current 150/124 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 90 kW/125 HP
- Output current 180/156 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 110 kW/150 HP
- Output current 212/180 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
-
Fault message ID
704708510 0x2A00FF9E Description
CausePDSS - Creep velocity SCS exceeded
RemedyThe drive has exceeded the currently permitted SCS creeping speed.
Severity/responseCheck parameters for PDSS. Reduce speeds in the application. Increase distance to PDSS limit values.
Warning
-
Fault message ID
704708511 0x2A00FF9F Description
CausePDSS - No diagnostic mark detected
RemedyNo diagnostic marker for PDSS was detected.
Severity/responseAdapt parameters for the diagnostic marker. Check the function of the diagnostic sensors. Correct position of the diagnostic sensors.
Warning
-
Fault message ID
704708512 0x2A00FFA0 Description
CausePDSS - Diagnostic mark detected at invalid position
RemedyA diagnostic marker for PDSS was detected at an invalid position.
Severity/responseAdapt parameters for the diagnostic marker. Correct position of the diagnostic sensors.
Warning
-
Fault message ID
704708518 0x2A00FFA6 Description
CauseSHom - Time-out
RemedyAfter SHom_Start, the home position was not detected within the timeout set in 0x2882:002.
Severity/responseAdapt timeout. Check configuration of triggers for SHom_Start and SHom_Load.
Warning
-
Fault message ID
704708519 0x2A00FFA7 Description
CauseSHom - Home position deleted
RemedyThe home position was deleted by acknowledging a position error or manually via 0x2114:014.
Severity/responseExecute SHom again.
Information
-
Fault message ID
704708520 0x2A00FFA8 Description
CauseSHom - Maximum slip value exceeded
RemedyThe maximum permissible slip has been exceeded.
Severity/responseEvaluate slip monitoring in 0x2870:2. Check the wear-prone drive components and replace then if necessary.
Warning
-
Fault message ID
704708521 0x2A00FFA9 Description
CauseSHom - Tolerance of start position exceeded
RemedyThe tolerance for the starting position has been exceeded.
Severity/responseDo not move drive components while the mains voltage is switched off. Execute SHom again.
Warning
-
Fault message ID
704708522 0x2A00FFAA Description
CauseSHom - Tolerance of position comparison exceeded
RemedyThe tolerance for the position comparison has been exceeded.
Severity/responseCheck gearbox factor and mounting direction. Check the wear-prone drive components and replace then if necessary. Execute SHom again.
Warning
-
Fault message ID
704708523 0x2A00FFAB Description
CauseSSM - Invalid safe velocity
RemedyNo safe speed could be determined. The encoder is not initialized or the status transmitted by the encoder is invalid.
Severity/responseCheck encoder. A certified motor/encoder combination must be used.
Warning
-
Fault message ID
704708524 0x2A00FFAC Description
CauseSSM - Encoder error
RemedyThe monitoring of the safe speed via encoder is faulty.
Severity/responseCheck encoder. Check configuration of the encoder.
Warning
-
Fault message ID
704708525 0x2A00FFAD Description
CauseSSM - Resolver error
RemedyThe monitoring of the safe speed via resolver is faulty.
Severity/responseCheck encoder. Check configuration of the encoder.
Warning
-
Fault message ID
704708526 0x2A00FFAE Description
CauseSSM - Error in standard device data
RemedySafe speed monitoring is faulty because the device is transmitting incorrect data.
Severity/responseCheck encoder. Check configuration of the encoder.
Warning
-
Fault message ID
704708527 0x2A00FFAF Description
CauseSSM - Speed deviation too high
RemedyThe difference between the internally calculated speed and the speed transmitted by the encoder is too large.
Severity/responseCheck configuration of the encoder. Check gearbox factor. Check tolerance for the deviation.
Warning
-
Fault message ID
704708528 0x2A00FFB0 Description
CauseSSM - Synchronization error
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
Fault message ID
704708529 0x2A00FFB1 Description
CauseMUT - Muting function active
RemedyMUT - Muting function active
Severity/responseFor information only. No remedy necessary.
Information
-
Fault message ID
704708530 0x2A00FFB2 Description
CauseMUT - Muting function completed
RemedyMUT - Muting function completed
Severity/responseFor information only. No remedy necessary.
Information
-
Fault message ID
704708531 0x2A00FFB3 Description
CauseMUT - Muting function aborted
RemedyCommunication error. The muting function was canceled.
Severity/responseReconnect to the device. Restart the muting function.
Information
-
Fault message ID
704708536 0x2A00FFB8 Description
CauseHDSL encoder - ID was set
RemedyThe encoder ID of the connected HIPERFACE DSL® encoder has been set to the correct value. The error Different encoder ID has been fixed. The status bit has been reset: 0x2878:050, bit 13
Severity/responseCheck whether the encoder-axis assignment is now correct.
Information
-
Fault message ID
805306384 0x30000010 Description
CauseInternal error
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
Fault message ID
805306385 0x30000011 Description
CauseInternal error
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
Fault message ID
805306386 0x30000012 Description
CauseInternal error
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
Fault message ID
805306387 0x30000013 Description
CauseInternal error
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
Fault message ID
805306570 0x300000CA Description
CauseInternal error
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
Fault message ID
805306571 0x300000CB Description
CauseInternal error
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
Fault message ID
805311368 0x30001388 Description
CauseInternal error
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
0x2B02:009
Parameter
Frequency grid points (x) user V/f characteristic: x9 = f09 Data type
I16 Default setting
30 Hz Attributes
- -
0x2B02:010
Parameter
Frequency grid points (x) user V/f characteristic: x10 = f10 Data type
I16 Default setting
40 Hz Attributes
- -
0x2B02:011
Parameter
Frequency grid points (x) user V/f characteristic: x11 = f11 Data type
I16 Default setting
50 Hz Attributes
- -
0x2B03:001
Parameter
Voltage grid points (y) user V/f characteristic: y1 = U01 (x = f01) Data type
U32 Default setting
400.00 V Attributes
- -
0x2B03:002
Parameter
Voltage grid points (y) user V/f characteristic: y2 = U02 (x = f02) Data type
U32 Default setting
320.00 V Attributes
- -
0x2B03:003
Parameter
Voltage grid points (y) user V/f characteristic: y3 = U03 (x = f03) Data type
U32 Default setting
240.00 V Attributes
- -
0x2B03:004
Parameter
Voltage grid points (y) user V/f characteristic: y4 = U04 (x = f04) Data type
U32 Default setting
160.00 V Attributes
- -
0x2B03:005
Parameter
Voltage grid points (y) user V/f characteristic: y5 = U05 (x = f05) Data type
U32 Default setting
80.00 V Attributes
- -
0x2B03:006
Parameter
Voltage grid points (y) user V/f characteristic: y6 = U06 (x = f06) Data type
U32 Default setting
0.00 V Attributes
- -
0x2B03:007
Parameter
Voltage grid points (y) user V/f characteristic: y7 = U07 (x = f07) Data type
U32 Default setting
80.00 V Attributes
- -
0x2B03:008
Parameter
Voltage grid points (y) user V/f characteristic: y8 = U08 (x = f08) Data type
U32 Default setting
160.00 V Attributes
- -
0x2B03:009
Parameter
Voltage grid points (y) user V/f characteristic: y9 = U09 (x = f09) Data type
U32 Default setting
240.00 V Attributes
- -
0x2B03:010
Parameter
Voltage grid points (y) user V/f characteristic: y10 = U10 (x = f10) Data type
U32 Default setting
320.00 V Attributes
- -
0x2B03:011
Parameter
Voltage grid points (y) user V/f characteristic: y11 = U11 (x = f11) Data type
U32 Default setting
400.00 V Attributes
- -
0x2B04
Parameter
V/f boost controller - current setpoint Data type
U32 Default setting
0.00 A Attributes
- -
0x2B05:001
Parameter
V/f boost controller settings: Gain Data type
U32 Default setting
148.21 V/A Attributes
- -
0x2B05:002
Parameter
V/f boost controller settings: Reset time Data type
U32 Default setting
3.77 ms Attributes
- -
0x2B05:003
Parameter
V/f boost controller settings: Dynamic current setpoint Data type
U32 Default setting
0.00 A Attributes
- -
0x2B06
Parameter
Voltage boost Data type
U16 Default setting
0.0 V Attributes
- -
0x2B07:001
Parameter
Load adaption: Direction of rotation Data type
U8 Default setting
Passive load [0] Attributes
C -
0x2B07:002
Parameter
Load adaption: Load adaption value Data type
U32 Default setting
20.00 % Attributes
- -
0x2B08:001
Parameter
V/f Imax controller: Gain Data type
U32 Default setting
0.001 Hz/A Attributes
- -
0x2B08:002
Parameter
V/f Imax controller: Reset time Data type
U32 Default setting
100.0 ms Attributes
- -
0x2B09:001
Parameter
Slip compensation: Gain Data type
I16 Default setting
0.00 % Attributes
- -
0x2B09:002
Parameter
Slip compensation: Filter time Data type
U16 Default setting
2000 ms Attributes
-