i950
- Rated power 0.37 kW/0.5 HP
- Output current 2.4 A
- Output frequency 0-599 Hz
- Rated mains voltage 1/N(3)/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 0.55 kW/0.75 HP
- Output current 3.2 A
- Output frequency 0-599 Hz
- Rated mains voltage 1/N(3)/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 0.55 kW/0.75 HP
- Output current 1.8/1.6 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 0.75 kW/1 HP
- Output current 4.2 A
- Output frequency 0-599 Hz
- Rated mains voltage 1/N(3)/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 0.75 kW/1 HP
- Output current 2.4/2.1 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 1.5 kW/2 HP
- Output current 7 A
- Output frequency 0-599 Hz
- Rated mains voltage 1/N(3)/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 2.2 kW/3 HP
- Output current 9.6 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 2.2 kW/3 HP
- Output current 5.6/4.8 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 4 kW/5 HP
- Output current 16.5 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 4 kW/5 HP
- Output current 9.5/8.2 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 5.5 kW/7.5 HP
- Output current 23 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 7.5 kW/10 HP
- Output current 16.5/14 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 11 kW/15 HP
- Output current 23.5/21 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 15 kW/20 HP
- Output current 32/27 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 22 kW/30 HP
- Output current 47/40.4 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 30 kW/40 HP
- Output current 61/52 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 45 kW/60 HP
- Output current 89/77 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 55 kW/75 HP
- Output current 110/96 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 75 kW/100 HP
- Output current 150/124 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 90 kW/125 HP
- Output current 180/156 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 110 kW/150 HP
- Output current 212/180 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
-
Fault message ID
704680081 0x2A009091 Description
CauseSD-In3 - Channel B remains stuck at HIGH
RemedyChannel B of SD_In3 cannot be deactivated.
Severity/responseCheck wiring for short circuit. Check configuration of the safe input.
Warning
-
Fault message ID
704680082 0x2A009092 Description
CauseSD-In4 - Channel A remains stuck at HIGH
RemedyChannel A of SD_In4 cannot be deactivated.
Severity/responseCheck wiring for short circuit. Check configuration of the safe input.
Warning
-
Fault message ID
704680083 0x2A009093 Description
CauseSD-In4 - Channel B remains stuck at HIGH
RemedyChannel B of SD_In4 cannot be deactivated.
Severity/responseCheck wiring for short circuit. Check configuration of the safe input.
Warning
-
Fault message ID
704680084 0x2A009094 Description
CauseCLA/CLB - Short circuit
RemedyShort circuit at the CLA/CLB clock outputs.
Severity/responseCheck wiring.
Warning
-
Fault message ID
704708488 0x2A00FF88 Description
CauseSS1/SS2 - Stop time exceeded
RemedyThe speed threshold "n = 0" was not reached within the stopping time.
Severity/responseIncrease SS1/SS2- stopping time. Reduce delay time in drive.
Warning
-
Fault message ID
704708489 0x2A00FF89 Description
CauseSLS1 - Nlim1 exceeded
RemedyThe safely limited speed SLS1 has been exceeded.
Severity/responseAdapt the speed-dependent parameters in the drive. Increase safely limited speed.
Warning
-
Fault message ID
704708490 0x2A00FF8A Description
CauseSLS2 - Nlim2 exceeded
RemedyThe safely limited speed SLS2 has been exceeded.
Severity/responseAdapt the speed-dependent parameters in the drive. Increase safely limited speed.
Warning
-
Fault message ID
704708491 0x2A00FF8B Description
CauseSLS3 - Nlim3 exceeded
RemedyThe safely limited speed SLS3 has been exceeded.
Severity/responseAdapt the speed-dependent parameters in the drive. Increase safely limited speed.
Warning
-
Fault message ID
704708492 0x2A00FF8C Description
CauseSLS4 - Nlim4 exceeded
RemedyThe safely limited speed SLS4 has been exceeded.
Severity/responseAdapt the speed-dependent parameters in the drive. Increase safely limited speed.
Warning
-
Fault message ID
704708493 0x2A00FF8D Description
CauseSLS/SMS - Error stop not executed
RemedyA safely limited speed (SLS1-SLS4) or the maximum speed (SMS) has been exceeded. The error was not reported within the parameterized response time.
Severity/responseAdapt the speed-dependent parameters in the drive. Increase response time.
Warning
-
Fault message ID
704708494 0x2A00FF8E Description
CauseSDIpos - Wrong direction
RemedyThe drive has moved too far in the wrong direction.
Severity/responseAdapt the parameterization of the higher-level controller. Increase 0x28BA:003 tolerance threshold
Warning
-
Fault message ID
704708495 0x2A00FF8F Description
CauseSDIneg - Wrong direction
RemedyThe drive has moved too far in the wrong direction.
Severity/responseAdapt the parameterization of the higher-level controller. Increase 0x28BA:003 tolerance threshold
Warning
-
Fault message ID
704708496 0x2A00FF90 Description
CauseSMS - Nmax exceeded
RemedyThe drive has exceeded the parameterized safe maximum speed (SMS).
Severity/responseAdapt the maximum speed in the drive.
Warning
-
Fault message ID
704708497 0x2A00FF91 Description
CauseSOS - Tolerance limit exceeded
RemedyThe position change during SOS is greater than the parameterized tolerance window 0x289F:001.
Severity/responseIncrease tolerance window Adapt response time of encoder monitoring.
Warning
-
Fault message ID
704708498 0x2A00FF92 Description
CauseNo feedback system configured
RemedyAn attempt was made to call up a speed-based or position-based safety function although no feedback is configured.
Severity/responseConfigure suitable feedback.
Warning
-
Fault message ID
704708499 0x2A00FF93 Description
CauseCAS - Round trip time exceeded
RemedyThe maximum allowed time between activation of the cascading and the feedback of the nodes was exceeded.
Severity/responseSet the input delay of SD-In4 0x211A:004 to ≤ 10 ms. Check wiring between the nodes.
Warning
-
Fault message ID
704708500 0x2A00FF94 Description
CauseCAS - Hardware or discrepancy error
RemedyThe hardware did not turn off the cascading output fast enough. A discrepancy error has occurred at the cascading input.
Severity/responseCheck wiring between the nodes.
Warning
-
Fault message ID
704708501 0x2A00FF95 Description
CauseSS1/SS2 - Speed ramp exceeded
RemedyRamp monitoring has responded because monitoring limits have been exceeded.
Severity/responseAdapt parameters for ramp monitoring. (0x2894) Deactivate ramp monitoring.
Warning
-
Fault message ID
704708502 0x2A00FF96 Description
CauseSLI - Safely limited increment exceeded
RemedyThe maximum permissible position change (0x28CA:001, 0x28CA:003) was exceeded.
Severity/responseAdapt parameters for SLI.
Warning
-
Fault message ID
704708503 0x2A00FF97 Description
CauseSLP1 - Position limits exceeded
RemedyThe upper or lower position limit of SLP1 has been exceeded.
Severity/responseAdapt parameters for SLP1. Increase the distance to the position limits in the application.
Warning
-
Fault message ID
704708504 0x2A00FF98 Description
CauseSLP2 - Position limits exceeded
RemedyThe upper or lower position limit of SLP2 has been exceeded.
Severity/responseAdapt parameters for SLP2. Increase the distance to the position limits in the application.
Warning
-
Fault message ID
704708505 0x2A00FF99 Description
CauseSLP3 - Position limits exceeded
RemedyThe upper or lower position limit of SLP3 has been exceeded.
Severity/responseAdapt parameters for SLP3. Increase the distance to the position limits in the application.
Warning
-
Fault message ID
704708506 0x2A00FF9A Description
CauseSLP4 - Position limits exceeded
RemedyThe upper or lower position limit of SLP4 has been exceeded.
Severity/responseAdapt parameters for SLP4. Increase the distance to the position limits in the application.
Warning
-
Fault message ID
704708507 0x2A00FF9B Description
CauseSLP - No home position
RemedySLP has been commissioned, but the home position is unknown.
Severity/responseCheck status of the safe reference. (0x2882:006)
Warning
-
Fault message ID
704708509 0x2A00FF9D Description
CausePDSS - Velocity exceeded
RemedyThe drive has exceeded the current allowed speed for PDSS.
Severity/responseCheck parameters for PDSS. Reduce speeds in the application. Increase distance to PDSS limit values.
Warning
-
0x60B2
Parameter
Offset torque Data type
I16 Default setting
0.0 % Attributes
- -
0x60B8
Parameter
Touch probe settings Data type
U16 Default setting
0x0000 Attributes
H -
0x60B9
Parameter
Touch probe status Data type
U16 Default setting
- (Read only) Attributes
H -
0x60BA
Parameter
Touch probe 1: Position at pos. edge Data type
I32 Default setting
- (Read only) Attributes
- -
0x60BB
Parameter
Touch probe 1: Position at neg. edge Data type
I32 Default setting
- (Read only) Attributes
- -
0x60BC
Parameter
Touch probe 2: Position at pos. edge Data type
I32 Default setting
- (Read only) Attributes
- -
0x60BD
Parameter
Touch probe 2: Position at neg. edge Data type
I32 Default setting
- (Read only) Attributes
- -
0x60C0
Parameter
Interpolation mode Data type
I16 Default setting
Quadratic [-1] Attributes
- -
0x60C2:001
Parameter
Interpolation time: Interpolation time mantissa Data type
U8 Default setting
1 Attributes
- -
0x60C2:002
Parameter
Interpolation time: Interpolation time exponent Data type
I8 Default setting
-3 Attributes
- -
0x60E0
Parameter
Positive torque limit Data type
U16 Default setting
100.0 % Attributes
- -
0x60E1
Parameter
Negative torque limit Data type
U16 Default setting
100.0 % Attributes
- -
0x60E4:001
Parameter
Additional position actual value: Load encoder/ master encoder - actual position Data type
I32 Default setting
- (Read only) Attributes
- -
0x60E5:001
Parameter
Additional velocity actual value: Load encoder/ master encoder - actual speed Data type
I32 Default setting
rpm (Read only) Attributes
- -
0x60E6:001
Parameter
Additional position encoder resolution - encoder increments: Load encoder/master encoder - number of increments Data type
U32 Default setting
16 Bit [65536] Attributes
C -
0x60EB:001
Parameter
Additional position encoder resolution - motor revolutions: Load encoder/master encoder - resolution of motor revolutions Data type
U32 Default setting
1 Attributes
C -
0x60F4
Parameter
Following error actual value Data type
I32 Default setting
- (Read only) Attributes
- -
0x60FA
Parameter
Control effort Data type
I32 Default setting
rpm (Read only) Attributes
- -
0x60FC
Parameter
Position demand internal value Data type
I32 Default setting
- (Read only) Attributes
- -
0x60FD
Parameter
Digital input status Data type
U32 Default setting
- (Read only) Attributes
H -
0x60FE:001
Parameter
Digital outputs: Digital output status Data type
U32 Default setting
0x00000000 Attributes
H -
0x60FF
Parameter
Set speed Data type
I32 Default setting
0.00 rpm Attributes
- -
0x6404
Parameter
Motor manufacturer Data type
STRING[50] Default setting
"Lenze" Attributes
- -
0x6502
Parameter
Supported drive modes Data type
U32 Default setting
- (Read only) Attributes
H -
0x67FF
Parameter
Device profile number Data type
U32 Default setting
- (Read only) Attributes
-
No results.