i950
- Rated power 0.37 kW/0.5 HP
- Output current 2.4 A
- Output frequency 0-599 Hz
- Rated mains voltage 1/N(3)/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 0.55 kW/0.75 HP
- Output current 3.2 A
- Output frequency 0-599 Hz
- Rated mains voltage 1/N(3)/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 0.55 kW/0.75 HP
- Output current 1.8/1.6 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 0.75 kW/1 HP
- Output current 4.2 A
- Output frequency 0-599 Hz
- Rated mains voltage 1/N(3)/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 0.75 kW/1 HP
- Output current 2.4/2.1 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 1.5 kW/2 HP
- Output current 7 A
- Output frequency 0-599 Hz
- Rated mains voltage 1/N(3)/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 2.2 kW/3 HP
- Output current 9.6 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 2.2 kW/3 HP
- Output current 5.6/4.8 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 4 kW/5 HP
- Output current 16.5 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 4 kW/5 HP
- Output current 9.5/8.2 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 5.5 kW/7.5 HP
- Output current 23 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 7.5 kW/10 HP
- Output current 16.5/14 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 11 kW/15 HP
- Output current 23.5/21 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 15 kW/20 HP
- Output current 32/27 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 22 kW/30 HP
- Output current 47/40.4 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 30 kW/40 HP
- Output current 61/52 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 45 kW/60 HP
- Output current 89/77 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 55 kW/75 HP
- Output current 110/96 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 75 kW/100 HP
- Output current 150/124 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 90 kW/125 HP
- Output current 180/156 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 110 kW/150 HP
- Output current 212/180 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
-
Fault message ID
704680081 0x2A009091 Description
CauseSD-In3 - Channel B remains stuck at HIGH
RemedyChannel B of SD_In3 cannot be deactivated.
Severity/responseCheck wiring for short circuit. Check configuration of the safe input.
Warning
-
Fault message ID
704680082 0x2A009092 Description
CauseSD-In4 - Channel A remains stuck at HIGH
RemedyChannel A of SD_In4 cannot be deactivated.
Severity/responseCheck wiring for short circuit. Check configuration of the safe input.
Warning
-
Fault message ID
704680083 0x2A009093 Description
CauseSD-In4 - Channel B remains stuck at HIGH
RemedyChannel B of SD_In4 cannot be deactivated.
Severity/responseCheck wiring for short circuit. Check configuration of the safe input.
Warning
-
Fault message ID
704680084 0x2A009094 Description
CauseCLA/CLB - Short circuit
RemedyShort circuit at the CLA/CLB clock outputs.
Severity/responseCheck wiring.
Warning
-
Fault message ID
704708488 0x2A00FF88 Description
CauseSS1/SS2 - Stop time exceeded
RemedyThe speed threshold "n = 0" was not reached within the stopping time.
Severity/responseIncrease SS1/SS2- stopping time. Reduce delay time in drive.
Warning
-
Fault message ID
704708489 0x2A00FF89 Description
CauseSLS1 - Nlim1 exceeded
RemedyThe safely limited speed SLS1 has been exceeded.
Severity/responseAdapt the speed-dependent parameters in the drive. Increase safely limited speed.
Warning
-
Fault message ID
704708490 0x2A00FF8A Description
CauseSLS2 - Nlim2 exceeded
RemedyThe safely limited speed SLS2 has been exceeded.
Severity/responseAdapt the speed-dependent parameters in the drive. Increase safely limited speed.
Warning
-
Fault message ID
704708491 0x2A00FF8B Description
CauseSLS3 - Nlim3 exceeded
RemedyThe safely limited speed SLS3 has been exceeded.
Severity/responseAdapt the speed-dependent parameters in the drive. Increase safely limited speed.
Warning
-
Fault message ID
704708492 0x2A00FF8C Description
CauseSLS4 - Nlim4 exceeded
RemedyThe safely limited speed SLS4 has been exceeded.
Severity/responseAdapt the speed-dependent parameters in the drive. Increase safely limited speed.
Warning
-
Fault message ID
704708493 0x2A00FF8D Description
CauseSLS/SMS - Error stop not executed
RemedyA safely limited speed (SLS1-SLS4) or the maximum speed (SMS) has been exceeded. The error was not reported within the parameterized response time.
Severity/responseAdapt the speed-dependent parameters in the drive. Increase response time.
Warning
-
Fault message ID
704708494 0x2A00FF8E Description
CauseSDIpos - Wrong direction
RemedyThe drive has moved too far in the wrong direction.
Severity/responseAdapt the parameterization of the higher-level controller. Increase 0x28BA:003 tolerance threshold
Warning
-
Fault message ID
704708495 0x2A00FF8F Description
CauseSDIneg - Wrong direction
RemedyThe drive has moved too far in the wrong direction.
Severity/responseAdapt the parameterization of the higher-level controller. Increase 0x28BA:003 tolerance threshold
Warning
-
Fault message ID
704708496 0x2A00FF90 Description
CauseSMS - Nmax exceeded
RemedyThe drive has exceeded the parameterized safe maximum speed (SMS).
Severity/responseAdapt the maximum speed in the drive.
Warning
-
Fault message ID
704708497 0x2A00FF91 Description
CauseSOS - Tolerance limit exceeded
RemedyThe position change during SOS is greater than the parameterized tolerance window 0x289F:001.
Severity/responseIncrease tolerance window Adapt response time of encoder monitoring.
Warning
-
Fault message ID
704708498 0x2A00FF92 Description
CauseNo feedback system configured
RemedyAn attempt was made to call up a speed-based or position-based safety function although no feedback is configured.
Severity/responseConfigure suitable feedback.
Warning
-
Fault message ID
704708499 0x2A00FF93 Description
CauseCAS - Round trip time exceeded
RemedyThe maximum allowed time between activation of the cascading and the feedback of the nodes was exceeded.
Severity/responseSet the input delay of SD-In4 0x211A:004 to ≤ 10 ms. Check wiring between the nodes.
Warning
-
Fault message ID
704708500 0x2A00FF94 Description
CauseCAS - Hardware or discrepancy error
RemedyThe hardware did not turn off the cascading output fast enough. A discrepancy error has occurred at the cascading input.
Severity/responseCheck wiring between the nodes.
Warning
-
Fault message ID
704708501 0x2A00FF95 Description
CauseSS1/SS2 - Speed ramp exceeded
RemedyRamp monitoring has responded because monitoring limits have been exceeded.
Severity/responseAdapt parameters for ramp monitoring. (0x2894) Deactivate ramp monitoring.
Warning
-
Fault message ID
704708502 0x2A00FF96 Description
CauseSLI - Safely limited increment exceeded
RemedyThe maximum permissible position change (0x28CA:001, 0x28CA:003) was exceeded.
Severity/responseAdapt parameters for SLI.
Warning
-
Fault message ID
704708503 0x2A00FF97 Description
CauseSLP1 - Position limits exceeded
RemedyThe upper or lower position limit of SLP1 has been exceeded.
Severity/responseAdapt parameters for SLP1. Increase the distance to the position limits in the application.
Warning
-
Fault message ID
704708504 0x2A00FF98 Description
CauseSLP2 - Position limits exceeded
RemedyThe upper or lower position limit of SLP2 has been exceeded.
Severity/responseAdapt parameters for SLP2. Increase the distance to the position limits in the application.
Warning
-
Fault message ID
704708505 0x2A00FF99 Description
CauseSLP3 - Position limits exceeded
RemedyThe upper or lower position limit of SLP3 has been exceeded.
Severity/responseAdapt parameters for SLP3. Increase the distance to the position limits in the application.
Warning
-
Fault message ID
704708506 0x2A00FF9A Description
CauseSLP4 - Position limits exceeded
RemedyThe upper or lower position limit of SLP4 has been exceeded.
Severity/responseAdapt parameters for SLP4. Increase the distance to the position limits in the application.
Warning
-
Fault message ID
704708507 0x2A00FF9B Description
CauseSLP - No home position
RemedySLP has been commissioned, but the home position is unknown.
Severity/responseCheck status of the safe reference. (0x2882:006)
Warning
-
Fault message ID
704708509 0x2A00FF9D Description
CausePDSS - Velocity exceeded
RemedyThe drive has exceeded the current allowed speed for PDSS.
Severity/responseCheck parameters for PDSS. Reduce speeds in the application. Increase distance to PDSS limit values.
Warning
-
0x2D40:007
Parameter
Device utilisation ixt: Actual total utilisation Data type
U16 Default setting
x % (Read only) Attributes
- -
0x2D40:008
Parameter
Device utilisation ixt: Total utilisation warning threshold Data type
U16 Default setting
95 % Attributes
- -
0x2D40:009
Parameter
Device utilisation ixt: Total utilisation error threshold Data type
U16 Default setting
x % (Read only) Attributes
- -
0x2D44:001
Parameter
Overspeed monitoring: Threshold Data type
U16 Default setting
8000 rpm Attributes
- -
0x2D44:002
Parameter
Overspeed monitoring: Response Data type
U8 Default setting
Fault > CiA402 [1] Attributes
- -
0x2D45:001
Parameter
Motor phase failure detection: Response - Motor phase 1 Data type
U8 Default setting
No response [0] Attributes
- -
0x2D45:002
Parameter
Motor phase failure detection: Current threshold Data type
U8 Default setting
5.0 % Attributes
- -
0x2D45:003
Parameter
Motor phase failure detection: Voltage threshold Data type
U16 Default setting
10.0 V Attributes
- -
0x2D45:004
Parameter
Motor phase failure detection: Response - Motor phase 2 Data type
U8 Default setting
No response [0] Attributes
- -
0x2D46:001
Parameter
Overcurrent monitoring: Threshold Data type
U16 Default setting
5.4 A Attributes
- -
0x2D46:002
Parameter
Overcurrent monitoring: Response Data type
U8 Default setting
Fault > CiA402 [1] Attributes
- -
0x2D48:002
Parameter
PTC temperature sensor monitoring: Error response Data type
U8 Default setting
Fault > CiA402 [1] Attributes
- -
0x2D49:001
Parameter
Motor temperature monitoring: Temperature sensor type Data type
U8 Default setting
PT1000 [5] Attributes
- -
0x2D49:002
Parameter
Motor temperature monitoring: Response Data type
U8 Default setting
Warning [1] Attributes
- -
0x2D49:003
Parameter
Motor temperature monitoring: Warning threshold Data type
I16 Default setting
145.0 °C Attributes
- -
0x2D49:004
Parameter
Motor temperature monitoring: Error threshold Data type
I16 Default setting
155.0 °C Attributes
- -
0x2D49:005
Parameter
Motor temperature monitoring: Actual motor temperature Data type
I16 Default setting
x.x °C (Read only) Attributes
- -
0x2D49:006
Parameter
Motor temperature monitoring: Spec. characteristic temperature grid point 1 Data type
I16 Default setting
25.0 °C Attributes
- -
0x2D49:007
Parameter
Motor temperature monitoring: Spec. characteristic temperature grid point 2 Data type
I16 Default setting
150.0 °C Attributes
- -
0x2D49:008
Parameter
Motor temperature monitoring: Spec. characteristic resistance grid point 1 Data type
I16 Default setting
1000 Ω Attributes
- -
0x2D49:009
Parameter
Motor temperature monitoring: Spec. characteristic resistance grid point 2 Data type
I16 Default setting
2225 Ω Attributes
- -
0x2D49:010
Parameter
Motor temperature monitoring: Temperature sensor feedback type Data type
U8 Default setting
Motor encoder [0] Attributes
- -
0x2D49:011
Parameter
Motor temperature monitoring: Motor temperature (Motor encoder) Data type
I16 Default setting
x.x °C (Read only) Attributes
- -
0x2D49:012
Parameter
Motor temperature monitoring: Motor temperature (load encoder) Data type
I16 Default setting
x.x °C (Read only) Attributes
- -
0x2D4C:001
Parameter
Thermal model motor utilization (i²xt): Motor utilisation (i²xt) Data type
U16 Default setting
60 s Attributes
-