i950
- Rated power 0.37 kW/0.5 HP
- Output current 2.4 A
- Output frequency 0-599 Hz
- Rated mains voltage 1/N(3)/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 0.55 kW/0.75 HP
- Output current 3.2 A
- Output frequency 0-599 Hz
- Rated mains voltage 1/N(3)/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 0.55 kW/0.75 HP
- Output current 1.8/1.6 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 0.75 kW/1 HP
- Output current 4.2 A
- Output frequency 0-599 Hz
- Rated mains voltage 1/N(3)/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 0.75 kW/1 HP
- Output current 2.4/2.1 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 1.5 kW/2 HP
- Output current 7 A
- Output frequency 0-599 Hz
- Rated mains voltage 1/N(3)/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 2.2 kW/3 HP
- Output current 9.6 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 2.2 kW/3 HP
- Output current 5.6/4.8 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 4 kW/5 HP
- Output current 16.5 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 4 kW/5 HP
- Output current 9.5/8.2 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 5.5 kW/7.5 HP
- Output current 23 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 7.5 kW/10 HP
- Output current 16.5/14 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 11 kW/15 HP
- Output current 23.5/21 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 15 kW/20 HP
- Output current 32/27 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 22 kW/30 HP
- Output current 47/40.4 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 30 kW/40 HP
- Output current 61/52 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 45 kW/60 HP
- Output current 89/77 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 55 kW/75 HP
- Output current 110/96 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 75 kW/100 HP
- Output current 150/124 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 90 kW/125 HP
- Output current 180/156 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 110 kW/150 HP
- Output current 212/180 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
-
Fault message ID
704680081 0x2A009091 Description
CauseSD-In3 - Channel B remains stuck at HIGH
RemedyChannel B of SD_In3 cannot be deactivated.
Severity/responseCheck wiring for short circuit. Check configuration of the safe input.
Warning
-
Fault message ID
704680082 0x2A009092 Description
CauseSD-In4 - Channel A remains stuck at HIGH
RemedyChannel A of SD_In4 cannot be deactivated.
Severity/responseCheck wiring for short circuit. Check configuration of the safe input.
Warning
-
Fault message ID
704680083 0x2A009093 Description
CauseSD-In4 - Channel B remains stuck at HIGH
RemedyChannel B of SD_In4 cannot be deactivated.
Severity/responseCheck wiring for short circuit. Check configuration of the safe input.
Warning
-
Fault message ID
704680084 0x2A009094 Description
CauseCLA/CLB - Short circuit
RemedyShort circuit at the CLA/CLB clock outputs.
Severity/responseCheck wiring.
Warning
-
Fault message ID
704708488 0x2A00FF88 Description
CauseSS1/SS2 - Stop time exceeded
RemedyThe speed threshold "n = 0" was not reached within the stopping time.
Severity/responseIncrease SS1/SS2- stopping time. Reduce delay time in drive.
Warning
-
Fault message ID
704708489 0x2A00FF89 Description
CauseSLS1 - Nlim1 exceeded
RemedyThe safely limited speed SLS1 has been exceeded.
Severity/responseAdapt the speed-dependent parameters in the drive. Increase safely limited speed.
Warning
-
Fault message ID
704708490 0x2A00FF8A Description
CauseSLS2 - Nlim2 exceeded
RemedyThe safely limited speed SLS2 has been exceeded.
Severity/responseAdapt the speed-dependent parameters in the drive. Increase safely limited speed.
Warning
-
Fault message ID
704708491 0x2A00FF8B Description
CauseSLS3 - Nlim3 exceeded
RemedyThe safely limited speed SLS3 has been exceeded.
Severity/responseAdapt the speed-dependent parameters in the drive. Increase safely limited speed.
Warning
-
Fault message ID
704708492 0x2A00FF8C Description
CauseSLS4 - Nlim4 exceeded
RemedyThe safely limited speed SLS4 has been exceeded.
Severity/responseAdapt the speed-dependent parameters in the drive. Increase safely limited speed.
Warning
-
Fault message ID
704708493 0x2A00FF8D Description
CauseSLS/SMS - Error stop not executed
RemedyA safely limited speed (SLS1-SLS4) or the maximum speed (SMS) has been exceeded. The error was not reported within the parameterized response time.
Severity/responseAdapt the speed-dependent parameters in the drive. Increase response time.
Warning
-
Fault message ID
704708494 0x2A00FF8E Description
CauseSDIpos - Wrong direction
RemedyThe drive has moved too far in the wrong direction.
Severity/responseAdapt the parameterization of the higher-level controller. Increase 0x28BA:003 tolerance threshold
Warning
-
Fault message ID
704708495 0x2A00FF8F Description
CauseSDIneg - Wrong direction
RemedyThe drive has moved too far in the wrong direction.
Severity/responseAdapt the parameterization of the higher-level controller. Increase 0x28BA:003 tolerance threshold
Warning
-
Fault message ID
704708496 0x2A00FF90 Description
CauseSMS - Nmax exceeded
RemedyThe drive has exceeded the parameterized safe maximum speed (SMS).
Severity/responseAdapt the maximum speed in the drive.
Warning
-
Fault message ID
704708497 0x2A00FF91 Description
CauseSOS - Tolerance limit exceeded
RemedyThe position change during SOS is greater than the parameterized tolerance window 0x289F:001.
Severity/responseIncrease tolerance window Adapt response time of encoder monitoring.
Warning
-
Fault message ID
704708498 0x2A00FF92 Description
CauseNo feedback system configured
RemedyAn attempt was made to call up a speed-based or position-based safety function although no feedback is configured.
Severity/responseConfigure suitable feedback.
Warning
-
Fault message ID
704708499 0x2A00FF93 Description
CauseCAS - Round trip time exceeded
RemedyThe maximum allowed time between activation of the cascading and the feedback of the nodes was exceeded.
Severity/responseSet the input delay of SD-In4 0x211A:004 to ≤ 10 ms. Check wiring between the nodes.
Warning
-
Fault message ID
704708500 0x2A00FF94 Description
CauseCAS - Hardware or discrepancy error
RemedyThe hardware did not turn off the cascading output fast enough. A discrepancy error has occurred at the cascading input.
Severity/responseCheck wiring between the nodes.
Warning
-
Fault message ID
704708501 0x2A00FF95 Description
CauseSS1/SS2 - Speed ramp exceeded
RemedyRamp monitoring has responded because monitoring limits have been exceeded.
Severity/responseAdapt parameters for ramp monitoring. (0x2894) Deactivate ramp monitoring.
Warning
-
Fault message ID
704708502 0x2A00FF96 Description
CauseSLI - Safely limited increment exceeded
RemedyThe maximum permissible position change (0x28CA:001, 0x28CA:003) was exceeded.
Severity/responseAdapt parameters for SLI.
Warning
-
Fault message ID
704708503 0x2A00FF97 Description
CauseSLP1 - Position limits exceeded
RemedyThe upper or lower position limit of SLP1 has been exceeded.
Severity/responseAdapt parameters for SLP1. Increase the distance to the position limits in the application.
Warning
-
Fault message ID
704708504 0x2A00FF98 Description
CauseSLP2 - Position limits exceeded
RemedyThe upper or lower position limit of SLP2 has been exceeded.
Severity/responseAdapt parameters for SLP2. Increase the distance to the position limits in the application.
Warning
-
Fault message ID
704708505 0x2A00FF99 Description
CauseSLP3 - Position limits exceeded
RemedyThe upper or lower position limit of SLP3 has been exceeded.
Severity/responseAdapt parameters for SLP3. Increase the distance to the position limits in the application.
Warning
-
Fault message ID
704708506 0x2A00FF9A Description
CauseSLP4 - Position limits exceeded
RemedyThe upper or lower position limit of SLP4 has been exceeded.
Severity/responseAdapt parameters for SLP4. Increase the distance to the position limits in the application.
Warning
-
Fault message ID
704708507 0x2A00FF9B Description
CauseSLP - No home position
RemedySLP has been commissioned, but the home position is unknown.
Severity/responseCheck status of the safe reference. (0x2882:006)
Warning
-
Fault message ID
704708509 0x2A00FF9D Description
CausePDSS - Velocity exceeded
RemedyThe drive has exceeded the current allowed speed for PDSS.
Severity/responseCheck parameters for PDSS. Reduce speeds in the application. Increase distance to PDSS limit values.
Warning
-
0x2822:029
Parameter
Axis commands: Get load encoder/master encoder characteristic (resolver) Data type
U8 Default setting
Off/Ready [0] Attributes
- -
0x2822:030
Parameter
Axis commands: Get load encoder/master encoder information (HIPERFACE®) Data type
U8 Default setting
Off/Ready [0] Attributes
- -
0x2822:037
Parameter
Axis commands: Estimate all motor parameters based on rated data Data type
U8 Default setting
Off/Ready [0] Attributes
- -
0x2822:038
Parameter
Axis commands: HIPERFACE (A): Set position with synchronization Data type
U8 Default setting
Off/Ready [0] Attributes
- -
0x2822:039
Parameter
Axis commands: HIPERFACE (A): Set position with synchronization Data type
U8 Default setting
Off/Ready [0] Attributes
- -
0x2822:042
Parameter
Axis commands: Calculate speed filter time constant Data type
U8 Default setting
Off/Ready [0] Attributes
- -
0x2822:043
Parameter
Axis commands: Load power dependent motor parameters Data type
U8 Default setting
RANLI_C2822_S043_GEN_V00000000 [0] Attributes
- -
0x2822:044
Parameter
Axis commands: Cogging torque compensation Data type
U8 Default setting
RANLI_C2822_S044_GEN_V00000000 [0] Attributes
- -
0x2823
Parameter
Status of axis commands Data type
U8 Default setting
x % (Read only) Attributes
- -
0x2824
Parameter
Control via PDO/Application Data type
U8 Default setting
Keypad [1] Attributes
C -
0x2825
Parameter
Drive mode selection Data type
U8 Default setting
CiA402 operating modes [0] Attributes
C -
0x2826
Parameter
Timeout for error response -> quickstop Data type
U32 Default setting
4 s Attributes
- -
0x282A:001
Parameter
Status words: Cause of disable Data type
U32 Default setting
- (Read only) Attributes
H -
0x282A:004
Parameter
Status words: Extended status word Data type
U16 Default setting
- (Read only) Attributes
H -
0x282C:001
Parameter
I/O diagnostic: Application level of the digital inputs Data type
U32 Default setting
- (Read only) Attributes
H -
0x282C:002
Parameter
I/O diagnostic: Digital output levels Data type
U32 Default setting
- (Read only) Attributes
H -
0x2830
Parameter
Inverter control word Data type
U16 Default setting
0x0000 Attributes
H -
0x2831
Parameter
Inverter status word Data type
U16 Default setting
- (Read only) Attributes
H -
0x2832
Parameter
Identification status Data type
U16 Default setting
- (Read only) Attributes
H -
0x2833
Parameter
Inverter status word 2 Data type
U16 Default setting
- (Read only) Attributes
H -
0x2835:001
Parameter
Manual test mode: Current setpoint Data type
I16 Default setting
0 % Attributes
- -
0x2835:002
Parameter
Manual test mode: Frequency Data type
I16 Default setting
0.0 Hz Attributes
- -
0x2835:003
Parameter
Manual test mode: Starting angle Data type
I16 Default setting
0.0 ° Attributes
- -
0x2836:001
Parameter
Manual control mode: Current setpoint Data type
U16 Default setting
30 % Attributes
- -
0x2836:002
Parameter
Manual control mode: Frequency Data type
I16 Default setting
0.0 Hz Attributes
-
No results.