i950

i950-C0.37/230-2 i950-C0.37/230-2 Description
Lenze logo Order code / SKU
On request
  • Rated power 0.37 kW/0.5 HP
  • Output current 2.4 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 1/N(3)/PE 230/240 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter not integrated
i950-C0.55/230-2 i950-C0.55/230-2 Description
Lenze logo Order code / SKU
On request
  • Rated power 0.55 kW/0.75 HP
  • Output current 3.2 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 1/N(3)/PE 230/240 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter not integrated
i950-C0.55/400-3 i950-C0.55/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 0.55 kW/0.75 HP
  • Output current 1.8/1.6 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter Integrated
i950-C0.75/230-2 i950-C0.75/230-2 Description
Lenze logo Order code / SKU
On request
  • Rated power 0.75 kW/1 HP
  • Output current 4.2 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 1/N(3)/PE 230/240 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter not integrated
i950-C0.75/400-3 i950-C0.75/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 0.75 kW/1 HP
  • Output current 2.4/2.1 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter Integrated
i950-C1.5/230-2 i950-C1.5/230-2 Description
Lenze logo Order code / SKU
On request
  • Rated power 1.5 kW/2 HP
  • Output current 7 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 1/N(3)/PE 230/240 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter not integrated
i950-C2.2/230-3 i950-C2.2/230-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 2.2 kW/3 HP
  • Output current 9.6 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 230/240 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter not integrated
i950-C2.2/400-3 i950-C2.2/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 2.2 kW/3 HP
  • Output current 5.6/4.8 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter Integrated
i950-C4/230-3 i950-C4/230-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 4 kW/5 HP
  • Output current 16.5 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 230/240 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter not integrated
i950-C4/400-3 i950-C4/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 4 kW/5 HP
  • Output current 9.5/8.2 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter Integrated
i950-C5.5/230-3 i950-C5.5/230-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 5.5 kW/7.5 HP
  • Output current 23 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 230/240 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter not integrated
i950-C7.5/400-3 i950-C7.5/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 7.5 kW/10 HP
  • Output current 16.5/14 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter Integrated
i950-C11/400-3 i950-C11/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 11 kW/15 HP
  • Output current 23.5/21 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter Integrated
i950-C15/400-3 i950-C15/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 15 kW/20 HP
  • Output current 32/27 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter Integrated
i950-C22/400-3 i950-C22/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 22 kW/30 HP
  • Output current 47/40.4 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter Integrated
i950-C30/400-3 i950-C30/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 30 kW/40 HP
  • Output current 61/52 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter Integrated
i950-C45/400-3 i950-C45/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 45 kW/60 HP
  • Output current 89/77 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter Integrated
i950-C55/400-3 i950-C55/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 55 kW/75 HP
  • Output current 110/96 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter Integrated
i950-C75/400-3 i950-C75/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 75 kW/100 HP
  • Output current 150/124 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter Integrated
i950-C90/400-3 i950-C90/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 90 kW/125 HP
  • Output current 180/156 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter Integrated
i950-C110/400-3 i950-C110/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 110 kW/150 HP
  • Output current 212/180 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter Integrated
Showing 176–200 of 563
  • Fault message ID
    704680081
    0x2A009091 Description

    SD-In3 - Channel B remains stuck at HIGH

    Cause

    Channel B of SD_In3 cannot be deactivated.

    Remedy

    Check wiring for short circuit. Check configuration of the safe input.

    Severity/response

    Warning

  • Fault message ID
    704680082
    0x2A009092 Description

    SD-In4 - Channel A remains stuck at HIGH

    Cause

    Channel A of SD_In4 cannot be deactivated.

    Remedy

    Check wiring for short circuit. Check configuration of the safe input.

    Severity/response

    Warning

  • Fault message ID
    704680083
    0x2A009093 Description

    SD-In4 - Channel B remains stuck at HIGH

    Cause

    Channel B of SD_In4 cannot be deactivated.

    Remedy

    Check wiring for short circuit. Check configuration of the safe input.

    Severity/response

    Warning

  • Fault message ID
    704680084
    0x2A009094 Description

    CLA/CLB - Short circuit

    Cause

    Short circuit at the CLA/CLB clock outputs.

    Remedy

    Check wiring.

    Severity/response

    Warning

  • Fault message ID
    704708488
    0x2A00FF88 Description

    SS1/SS2 - Stop time exceeded

    Cause

    The speed threshold "n = 0" was not reached within the stopping time.

    Remedy

    Increase SS1/SS2- stopping time. Reduce delay time in drive.

    Severity/response

    Warning

  • Fault message ID
    704708489
    0x2A00FF89 Description

    SLS1 - Nlim1 exceeded

    Cause

    The safely limited speed SLS1 has been exceeded.

    Remedy

    Adapt the speed-dependent parameters in the drive. Increase safely limited speed.

    Severity/response

    Warning

  • Fault message ID
    704708490
    0x2A00FF8A Description

    SLS2 - Nlim2 exceeded

    Cause

    The safely limited speed SLS2 has been exceeded.

    Remedy

    Adapt the speed-dependent parameters in the drive. Increase safely limited speed.

    Severity/response

    Warning

  • Fault message ID
    704708491
    0x2A00FF8B Description

    SLS3 - Nlim3 exceeded

    Cause

    The safely limited speed SLS3 has been exceeded.

    Remedy

    Adapt the speed-dependent parameters in the drive. Increase safely limited speed.

    Severity/response

    Warning

  • Fault message ID
    704708492
    0x2A00FF8C Description

    SLS4 - Nlim4 exceeded

    Cause

    The safely limited speed SLS4 has been exceeded.

    Remedy

    Adapt the speed-dependent parameters in the drive. Increase safely limited speed.

    Severity/response

    Warning

  • Fault message ID
    704708493
    0x2A00FF8D Description

    SLS/SMS - Error stop not executed

    Cause

    A safely limited speed (SLS1-SLS4) or the maximum speed (SMS) has been exceeded. The error was not reported within the parameterized response time.

    Remedy

    Adapt the speed-dependent parameters in the drive. Increase response time.

    Severity/response

    Warning

  • Fault message ID
    704708494
    0x2A00FF8E Description

    SDIpos - Wrong direction

    Cause

    The drive has moved too far in the wrong direction.

    Remedy

    Adapt the parameterization of the higher-level controller. Increase 0x28BA:003 tolerance threshold

    Severity/response

    Warning

  • Fault message ID
    704708495
    0x2A00FF8F Description

    SDIneg - Wrong direction

    Cause

    The drive has moved too far in the wrong direction.

    Remedy

    Adapt the parameterization of the higher-level controller. Increase 0x28BA:003 tolerance threshold

    Severity/response

    Warning

  • Fault message ID
    704708496
    0x2A00FF90 Description

    SMS - Nmax exceeded

    Cause

    The drive has exceeded the parameterized safe maximum speed (SMS).

    Remedy

    Adapt the maximum speed in the drive.

    Severity/response

    Warning

  • Fault message ID
    704708497
    0x2A00FF91 Description

    SOS - Tolerance limit exceeded

    Cause

    The position change during SOS is greater than the parameterized tolerance window 0x289F:001.

    Remedy

    Increase tolerance window Adapt response time of encoder monitoring.

    Severity/response

    Warning

  • Fault message ID
    704708498
    0x2A00FF92 Description

    No feedback system configured

    Cause

    An attempt was made to call up a speed-based or position-based safety function although no feedback is configured.

    Remedy

    Configure suitable feedback.

    Severity/response

    Warning

  • Fault message ID
    704708499
    0x2A00FF93 Description

    CAS - Round trip time exceeded

    Cause

    The maximum allowed time between activation of the cascading and the feedback of the nodes was exceeded.

    Remedy

    Set the input delay of SD-In4 0x211A:004 to ≤ 10 ms. Check wiring between the nodes.

    Severity/response

    Warning

  • Fault message ID
    704708500
    0x2A00FF94 Description

    CAS - Hardware or discrepancy error

    Cause

    The hardware did not turn off the cascading output fast enough. A discrepancy error has occurred at the cascading input.

    Remedy

    Check wiring between the nodes.

    Severity/response

    Warning

  • Fault message ID
    704708501
    0x2A00FF95 Description

    SS1/SS2 - Speed ramp exceeded

    Cause

    Ramp monitoring has responded because monitoring limits have been exceeded.

    Remedy

    Adapt parameters for ramp monitoring. (0x2894) Deactivate ramp monitoring.

    Severity/response

    Warning

  • Fault message ID
    704708502
    0x2A00FF96 Description

    SLI - Safely limited increment exceeded

    Cause

    The maximum permissible position change (0x28CA:001, 0x28CA:003) was exceeded.

    Remedy

    Adapt parameters for SLI.

    Severity/response

    Warning

  • Fault message ID
    704708503
    0x2A00FF97 Description

    SLP1 - Position limits exceeded

    Cause

    The upper or lower position limit of SLP1 has been exceeded.

    Remedy

    Adapt parameters for SLP1. Increase the distance to the position limits in the application.

    Severity/response

    Warning

  • Fault message ID
    704708504
    0x2A00FF98 Description

    SLP2 - Position limits exceeded

    Cause

    The upper or lower position limit of SLP2 has been exceeded.

    Remedy

    Adapt parameters for SLP2. Increase the distance to the position limits in the application.

    Severity/response

    Warning

  • Fault message ID
    704708505
    0x2A00FF99 Description

    SLP3 - Position limits exceeded

    Cause

    The upper or lower position limit of SLP3 has been exceeded.

    Remedy

    Adapt parameters for SLP3. Increase the distance to the position limits in the application.

    Severity/response

    Warning

  • Fault message ID
    704708506
    0x2A00FF9A Description

    SLP4 - Position limits exceeded

    Cause

    The upper or lower position limit of SLP4 has been exceeded.

    Remedy

    Adapt parameters for SLP4. Increase the distance to the position limits in the application.

    Severity/response

    Warning

  • Fault message ID
    704708507
    0x2A00FF9B Description

    SLP - No home position

    Cause

    SLP has been commissioned, but the home position is unknown.

    Remedy

    Check status of the safe reference. (0x2882:006)

    Severity/response

    Warning

  • Fault message ID
    704708509
    0x2A00FF9D Description

    PDSS - Velocity exceeded

    Cause

    The drive has exceeded the current allowed speed for PDSS.

    Remedy

    Check parameters for PDSS. Reduce speeds in the application. Increase distance to PDSS limit values.

    Severity/response

    Warning

← Previous Page 8 of 23 Next →

No results.