i950
- Rated power 0.37 kW/0.5 HP
- Output current 2.4 A
- Output frequency 0-599 Hz
- Rated mains voltage 1/N(3)/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 0.55 kW/0.75 HP
- Output current 3.2 A
- Output frequency 0-599 Hz
- Rated mains voltage 1/N(3)/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 0.55 kW/0.75 HP
- Output current 1.8/1.6 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 0.75 kW/1 HP
- Output current 4.2 A
- Output frequency 0-599 Hz
- Rated mains voltage 1/N(3)/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 0.75 kW/1 HP
- Output current 2.4/2.1 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 1.5 kW/2 HP
- Output current 7 A
- Output frequency 0-599 Hz
- Rated mains voltage 1/N(3)/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 2.2 kW/3 HP
- Output current 9.6 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 2.2 kW/3 HP
- Output current 5.6/4.8 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 4 kW/5 HP
- Output current 16.5 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 4 kW/5 HP
- Output current 9.5/8.2 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 5.5 kW/7.5 HP
- Output current 23 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 7.5 kW/10 HP
- Output current 16.5/14 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 11 kW/15 HP
- Output current 23.5/21 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 15 kW/20 HP
- Output current 32/27 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 22 kW/30 HP
- Output current 47/40.4 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 30 kW/40 HP
- Output current 61/52 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 45 kW/60 HP
- Output current 89/77 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 55 kW/75 HP
- Output current 110/96 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 75 kW/100 HP
- Output current 150/124 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 90 kW/125 HP
- Output current 180/156 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 110 kW/150 HP
- Output current 212/180 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
-
Fault message ID
704676259 0x2A0081A3 Description
Severity/responseiParameters - Restore, watchdog expired
Information
-
Fault message ID
704676260 0x2A0081A4 Description
Severity/responsePROFIsafe - iParCRC error
Information
-
Fault message ID
704676261 0x2A0081A5 Description
Severity/responsePROFIsafe - CRC2 error
Information
-
Fault message ID
704676262 0x2A0081A6 Description
Severity/responseF_WD_Time or F_WD_Time_2 expired
Information
-
Fault message ID
704676263 0x2A0081A7 Description
Severity/responseReserved (PROFIsafe standard)
Information
-
Fault message ID
704676264 0x2A0081A8 Description
CauseFSoE - Invalid slave address
RemedyThe slave address transmitted by the FSoE master differs from the slave address set in the device.
Severity/responseCheck slave address in the FSoE master. Check parameter setting in the device.
Information
-
Fault message ID
704676265 0x2A0081A9 Description
CauseFSoE - Invalid communication parameter length
RemedyThe length of the communication parameter transmitted by the FSoE master differs from the expected length.
Severity/responseCheck setting of the communication parameters.
Information
-
Fault message ID
704676266 0x2A0081AA Description
CauseFSoE - Data exchange left
RemedyDue to an error FSoE has left the data exchange.
Severity/responseCheck FSoE configuration. Reset error.
Information
-
Fault message ID
704680064 0x2A009080 Description
CauseDiscrepancy check or function check error - SD-In1
RemedySignal error at safe input SD-In1.
Severity/responseCheck parameter setting. Check wiring.
Warning
-
Fault message ID
704680065 0x2A009081 Description
CauseDiscrepancy check or function check error - SD-In2
RemedySignal error at safe input SD-In2.
Severity/responseCheck parameter setting. Check wiring.
Warning
-
Fault message ID
704680066 0x2A009082 Description
CauseDiscrepancy check or function check error - SD-In3
RemedySignal error at safe input SD-In3.
Severity/responseCheck parameter setting. Check wiring.
Warning
-
Fault message ID
704680067 0x2A009083 Description
CauseDiscrepancy check or function check error - SD-In4
RemedySignal error at safe input SD-In4.
Severity/responseCheck parameter setting. Check wiring.
Warning
-
Fault message ID
704680068 0x2A009084 Description
CauseDisabled SD-In1 = HIGH
RemedyInitialization error or parameterization error. HIGH level detected at the deactivated safe input.
Severity/responseCheck parameter setting. Check wiring.
Warning
-
Fault message ID
704680069 0x2A009085 Description
CauseDisabled SD-In2 = HIGH
RemedyInitialization error or parameterization error. HIGH level detected at the deactivated safe input.
Severity/responseCheck parameter setting. Check wiring.
Warning
-
Fault message ID
704680070 0x2A009086 Description
CauseDisabled SD-In3 = HIGH
RemedyInitialization error or parameterization error. HIGH level detected at the deactivated safe input.
Severity/responseCheck parameter setting. Check wiring.
Warning
-
Fault message ID
704680071 0x2A009087 Description
CauseDisabled SD-In4 = HIGH
RemedyInitialization error or parameterization error. HIGH level detected at the deactivated safe input.
Severity/responseCheck parameter setting. Check wiring.
Warning
-
Fault message ID
704680072 0x2A009088 Description
CauseSD-Out1 - Channel A remains stuck at HIGH
RemedyChannel A of SD_Out1 cannot be deactivated.
Severity/responseCheck wiring for short circuit.
Warning
-
Fault message ID
704680073 0x2A009089 Description
CauseSD-Out1 - Channel A remains stuck at LOW
RemedyChannel A of SD_Out1 cannot be activated.
Severity/responseCheck wiring. Check supply voltage.
Warning
-
Fault message ID
704680074 0x2A00908A Description
CauseSD-Out1 - Channel B remains stuck at HIGH
RemedyChannel B of SD_Out1 cannot be deactivated.
Severity/responseCheck wiring for short circuit.
Warning
-
Fault message ID
704680075 0x2A00908B Description
CauseSD-Out1 - Channel B remains stuck at LOW
RemedyChannel B of SD_Out1 cannot be activated.
Severity/responseCheck wiring. Check supply voltage.
Warning
-
Fault message ID
704680076 0x2A00908C Description
CauseSD-In1 - Channel A remains stuck at HIGH
RemedyChannel A of SD_In1 cannot be deactivated.
Severity/responseCheck wiring for short circuit. Check configuration of the safe input.
Warning
-
Fault message ID
704680077 0x2A00908D Description
CauseSD-In1 - Channel B remains stuck at HIGH
RemedyChannel B of SD_In1 cannot be deactivated.
Severity/responseCheck wiring for short circuit. Check configuration of the safe input.
Warning
-
Fault message ID
704680078 0x2A00908E Description
CauseSD-In2 - Channel A remains stuck at HIGH
RemedyChannel A of SD_In2 cannot be deactivated.
Severity/responseCheck wiring for short circuit. Check configuration of the safe input.
Warning
-
Fault message ID
704680079 0x2A00908F Description
CauseSD-In2 - Channel B remains stuck at HIGH
RemedyChannel B of SD_In2 cannot be deactivated.
Severity/responseCheck wiring for short circuit. Check configuration of the safe input.
Warning
-
Fault message ID
704680080 0x2A009090 Description
CauseSD-In3 - Channel A remains stuck at HIGH
RemedyChannel A of SD_In3 cannot be deactivated.
Severity/responseCheck wiring for short circuit. Check configuration of the safe input.
Warning
-
0x2C41:001
Parameter
Motor encoder settings (HIPERFACE®): Type code detected Data type
U8 Default setting
- (Read only) Attributes
- -
0x2C41:002
Parameter
Motor encoder settings (HIPERFACE®): Type code manual input Data type
U8 Default setting
0 Attributes
C -
0x2C41:003
Parameter
Motor encoder settings (HIPERFACE®): Manual input - Number of detectable motor encoder revolutions Data type
U16 Default setting
1 Attributes
C -
0x2C41:004
Parameter
Motor encoder settings (HIPERFACE®): Error response Data type
U8 Default setting
Fault > CiA402 [1] Attributes
- -
0x2C41:005
Parameter
Motor encoder settings (HIPERFACE®): Serial number Data type
STRING[50] Default setting
- (Read only) Attributes
- -
0x2C41:006
Parameter
Motor encoder settings (HIPERFACE®): Actual position (raw data) Data type
U32 Default setting
- (Read only) Attributes
- -
0x2C41:007
Parameter
Motor encoder settings (HIPERFACE®): No. of periods detected Data type
U16 Default setting
- (Read only) Attributes
- -
0x2C41:008
Parameter
Motor encoder settings (HIPERFACE®): Type code verification Data type
U8 Default setting
- (Read only) Attributes
- -
0x2C41:009
Parameter
Motor encoder settings (HIPERFACE®): Encoder type Data type
U8 Default setting
- (Read only) Attributes
- -
0x2C41:010
Parameter
Motor encoder settings (HIPERFACE®): Period length of linear encoder Data type
U32 Default setting
x nm (Read only) Attributes
- -
0x2C42:001
Parameter
Encoder settings: Increments/revolution Data type
U32 Default setting
1024 Attributes
C -
0x2C42:002
Parameter
Encoder settings: Supply voltage Data type
U8 Default setting
5.0 V Attributes
C -
0x2C42:003
Parameter
Encoder settings: Angle drift Data type
I16 Default setting
x.x ° (Read only) Attributes
- -
0x2C42:004
Parameter
Encoder settings: Actual amplitude signal quality Data type
U8 Default setting
x % (Read only) Attributes
- -
0x2C42:008
Parameter
Encoder settings: Encoder voltage cos track Data type
I16 Default setting
x.xxx V (Read only) Attributes
- -
0x2C42:009
Parameter
Encoder settings: Encoder voltage sin track Data type
I16 Default setting
x.xxx V (Read only) Attributes
- -
0x2C42:010
Parameter
Encoder settings: TTL/HTL signal evaluation Data type
U8 Default setting
High resolution encoder - 4-fold evaluation [1] Attributes
C -
0x2C43
Parameter
Motor encoder resolver number of pole pairs Data type
U8 Default setting
1 Attributes
C -
0x2C44:001
Parameter
Motor encoder identification (Resolver): Angle Data type
I16 Default setting
0 Attributes
- -
0x2C44:002
Parameter
Motor encoder identification (Resolver): Cosine track gain Data type
U16 Default setting
100 % Attributes
- -
0x2C44:003
Parameter
Motor encoder identification (Resolver): Sine track gain Data type
U16 Default setting
100 % Attributes
- -
0x2C44:006
Parameter
Motor encoder identification (Resolver): Identification status Data type
U16 Default setting
- (Read only) Attributes
H -
0x2C44:008
Parameter
Motor encoder identification (Resolver): Cosine track offset Data type
I32 Default setting
0.000 % Attributes
- -
0x2C44:009
Parameter
Motor encoder identification (Resolver): Sine track offset Data type
I32 Default setting
0.000 % Attributes
- -
0x2C44:011
Parameter
Motor encoder identification (Resolver): Cyclic online compensation Data type
U8 Default setting
[1] Attributes
-