i950

i950-C0.37/230-2 i950-C0.37/230-2 Description
Lenze logo Order code / SKU
On request
  • Rated power 0.37 kW/0.5 HP
  • Output current 2.4 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 1/N(3)/PE 230/240 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter not integrated
i950-C0.55/230-2 i950-C0.55/230-2 Description
Lenze logo Order code / SKU
On request
  • Rated power 0.55 kW/0.75 HP
  • Output current 3.2 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 1/N(3)/PE 230/240 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter not integrated
i950-C0.55/400-3 i950-C0.55/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 0.55 kW/0.75 HP
  • Output current 1.8/1.6 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter Integrated
i950-C0.75/230-2 i950-C0.75/230-2 Description
Lenze logo Order code / SKU
On request
  • Rated power 0.75 kW/1 HP
  • Output current 4.2 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 1/N(3)/PE 230/240 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter not integrated
i950-C0.75/400-3 i950-C0.75/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 0.75 kW/1 HP
  • Output current 2.4/2.1 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter Integrated
i950-C1.5/230-2 i950-C1.5/230-2 Description
Lenze logo Order code / SKU
On request
  • Rated power 1.5 kW/2 HP
  • Output current 7 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 1/N(3)/PE 230/240 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter not integrated
i950-C2.2/230-3 i950-C2.2/230-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 2.2 kW/3 HP
  • Output current 9.6 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 230/240 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter not integrated
i950-C2.2/400-3 i950-C2.2/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 2.2 kW/3 HP
  • Output current 5.6/4.8 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter Integrated
i950-C4/230-3 i950-C4/230-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 4 kW/5 HP
  • Output current 16.5 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 230/240 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter not integrated
i950-C4/400-3 i950-C4/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 4 kW/5 HP
  • Output current 9.5/8.2 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter Integrated
i950-C5.5/230-3 i950-C5.5/230-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 5.5 kW/7.5 HP
  • Output current 23 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 230/240 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter not integrated
i950-C7.5/400-3 i950-C7.5/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 7.5 kW/10 HP
  • Output current 16.5/14 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter Integrated
i950-C11/400-3 i950-C11/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 11 kW/15 HP
  • Output current 23.5/21 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter Integrated
i950-C15/400-3 i950-C15/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 15 kW/20 HP
  • Output current 32/27 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter Integrated
i950-C22/400-3 i950-C22/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 22 kW/30 HP
  • Output current 47/40.4 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter Integrated
i950-C30/400-3 i950-C30/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 30 kW/40 HP
  • Output current 61/52 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter Integrated
i950-C45/400-3 i950-C45/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 45 kW/60 HP
  • Output current 89/77 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter Integrated
i950-C55/400-3 i950-C55/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 55 kW/75 HP
  • Output current 110/96 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter Integrated
i950-C75/400-3 i950-C75/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 75 kW/100 HP
  • Output current 150/124 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter Integrated
i950-C90/400-3 i950-C90/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 90 kW/125 HP
  • Output current 180/156 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter Integrated
i950-C110/400-3 i950-C110/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 110 kW/150 HP
  • Output current 212/180 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter Integrated
Showing 126–150 of 563
  • Fault message ID
    704668554
    0x2A00638A Description

    New safety parameter set loaded

    Cause

    New safety parameter set loaded

    Remedy

    For information only. No remedy necessary.

    Severity/response

    Information

  • Fault message ID
    704668555
    0x2A00638B Description

    Memory module - Access error

    Cause

    Error accessing the safe parameter set on the SD card.

    Remedy

    Reset safe parameter set in the device. Reload safe parameter set.

    Severity/response

    Warning

  • Fault message ID
    704668556
    0x2A00638C Description

    Different safety parameter sets

    Cause

    The safe parameter sets on the SD card and in the device are different.

    Remedy

    Load a safe parameter set from the SD card into the device. Acknowledge modification with confirmation button S82.

    Severity/response

    Warning

  • Fault message ID
    704668557
    0x2A00638D Description

    Extended Safety - No safety parameter set

    Cause

    No safe parameter set was found in the device.

    Remedy

    Load safe parameter set into the device. Acknowledge modification with confirmation button S82.

    Severity/response

    Warning

  • Fault message ID
    704668558
    0x2A00638E Description

    Extended Safety - Safety parameter set defect

    Cause

    The safe parameter set in the device is faulty.

    Remedy

    Load safe parameter set into the device. Acknowledge modification with confirmation button S82.

    Severity/response

    Warning

  • Fault message ID
    704668559
    0x2A00638F Description

    Safety parameter set - Format error

    Cause

    Format error in the safe parameter set

    Remedy

    Reset the safe parameter set in the device and load it again. Acknowledge modification with confirmation button S82.

    Severity/response

    Warning

  • Fault message ID
    704668560
    0x2A006390 Description

    Safety parameter set - Plausibility error

    Cause

    The set safety parameters are not plausible.

    Remedy

    1.Determine the error number in 0x2115:005 and analyze it using the table of plausibility errors. 2.Correct error. 3.Reload safe parameter set. 4.Acknowledge modification with confirmation button S82.

    Severity/response

    Warning

  • Fault message ID
    704668561
    0x2A006391 Description

    Safety parameter set - Communication error

    Cause

    A communication error has occurred while loading the safe parameter set.

    Remedy
    • Check communication settings.
    • Check SD card.
    • Reload safe parameter set. Acknowledge modification with confirmation button S82.
    Severity/response

    Warning

  • Fault message ID
    704668562
    0x2A006392 Description

    Different safety addresses detected

    Cause

    The safety addresses in the device and on the SD card are different.

    Remedy
    • Adapt safety addresses.
    • Reload safe parameter set. Acknowledge modification with confirmation button S82.
    Severity/response

    Warning

  • Fault message ID
    704668563
    0x2A006393 Description

    SSM - Wrong PDO version

    Cause

    Safe speed monitoring is faulty because the PDO version of the data protocol is incompatible.

    Remedy

    Only devices with firmware > V1.0 support Extended Safety.

    Severity/response

    Warning

  • Fault message ID
    704668564
    0x2A006394 Description

    Memory module release information - access error

    Cause

    No release information is available on the memory module.

    Remedy

    After transferring an application with the "Application Loader", the release information for the safe parameter set must be generated separately for each device with the »EASY Starter« or »PLC Designer« via the +Safety parameter list+ and transferred to the device. After transmission, the safe parameter set must be saved in the device using the "Save" command.

    Severity/response

    Information

  • Fault message ID
    704676234
    0x2A00818A Description

    PROFIsafe passivated

    Cause

    Error in the PROFIsafe communication PROFIsafe was passivated.

    Remedy

    Check PROFIsafe component. Check network cable. Analyze the error history of the higher-level controller.

    Severity/response

    Information

  • Fault message ID
    704676235
    0x2A00818B Description

    PROFIsafe has left data exchange

    Cause

    Error in the PROFIsafe communication PROFIsafe has left data exchange.

    Remedy

    Check PROFIsafe component. Check network cable. Analyze the error history of the higher-level controller.

    Severity/response

    Information

  • Fault message ID
    704676237
    0x2A00818D Description

    PROFIsafe - CRC1 error

    Cause

    The F-Parameter-CRC is faulty.

    Remedy

    Check F-Parameter-CRC (CRC1) in the higher- level controller. Check device description file (GSDML).

    Severity/response

    Information

  • Fault message ID
    704676238
    0x2A00818E Description

    PROFIsafe - Device specific error

    Severity/response

    Information

  • Fault message ID
    704676239
    0x2A00818F Description

    iParameters - Saving, watchdog expired

    Severity/response

    Information

  • Fault message ID
    704676245
    0x2A008195 Description

    FSoE - Unexpected command

    Cause

    Unexpected FSoE command received.

    Remedy

    Check FSoE configuration. Restart communication.

    Severity/response

    Information

  • Fault message ID
    704676246
    0x2A008196 Description

    FSoE - Unknown command

    Cause

    Unknown FSoE command received.

    Remedy

    Check FSoE configuration. Restart communication.

    Severity/response

    Information

  • Fault message ID
    704676247
    0x2A008197 Description

    FSoE - Invalid connection ID

    Cause

    FSoE frame with invalid connection ID received.

    Remedy

    Check FSoE configuration. Restart communication.

    Severity/response

    Information

  • Fault message ID
    704676248
    0x2A008198 Description

    FSoE - CRC error

    Cause

    The check of the CRC in the FSoE frames reports errors.

    Remedy

    Check FSoE configuration. Restart communication.

    Severity/response

    Information

  • Fault message ID
    704676249
    0x2A008199 Description

    FSoE - Watchdog expired

    Cause

    FSoE watchdog elapsed.

    Remedy

    Check set watchdog time in FSoE master and adapt if necessary.

    Severity/response

    Information

  • Fault message ID
    704676252
    0x2A00819C Description

    FSoE - Invalid communication parameter data

    Cause

    Invalid communication parameter data received.

    Remedy

    Check setting of the communication parameters.

    Severity/response

    Information

  • Fault message ID
    704676253
    0x2A00819D Description

    FSoE - Invalid application parameter length

    Cause

    The length of the application parameters transmitted by the FSoE master differs from the expected length.

    Remedy

    Check setting of the communication parameters.

    Severity/response

    Information

  • Fault message ID
    704676254
    0x2A00819E Description

    FSoE - Invalid application parameter data

    Cause

    Invalid application parameter data received.

    Remedy

    Check setting of the communication parameters.

    Severity/response

    Information

  • Fault message ID
    704676255
    0x2A00819F Description

    FSoE - Passivated

    Cause

    Due to an error, FSoE was passivated.

    Remedy

    Check FSoE configuration. Reset error.

    Severity/response

    Information

← Previous Page 6 of 23 Next →