i950
- Rated power 0.37 kW/0.5 HP
- Output current 2.4 A
- Output frequency 0-599 Hz
- Rated mains voltage 1/N(3)/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 0.55 kW/0.75 HP
- Output current 3.2 A
- Output frequency 0-599 Hz
- Rated mains voltage 1/N(3)/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 0.55 kW/0.75 HP
- Output current 1.8/1.6 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 0.75 kW/1 HP
- Output current 4.2 A
- Output frequency 0-599 Hz
- Rated mains voltage 1/N(3)/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 0.75 kW/1 HP
- Output current 2.4/2.1 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 1.5 kW/2 HP
- Output current 7 A
- Output frequency 0-599 Hz
- Rated mains voltage 1/N(3)/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 2.2 kW/3 HP
- Output current 9.6 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 2.2 kW/3 HP
- Output current 5.6/4.8 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 4 kW/5 HP
- Output current 16.5 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 4 kW/5 HP
- Output current 9.5/8.2 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 5.5 kW/7.5 HP
- Output current 23 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 7.5 kW/10 HP
- Output current 16.5/14 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 11 kW/15 HP
- Output current 23.5/21 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 15 kW/20 HP
- Output current 32/27 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 22 kW/30 HP
- Output current 47/40.4 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 30 kW/40 HP
- Output current 61/52 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 45 kW/60 HP
- Output current 89/77 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 55 kW/75 HP
- Output current 110/96 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 75 kW/100 HP
- Output current 150/124 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 90 kW/125 HP
- Output current 180/156 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 110 kW/150 HP
- Output current 212/180 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
-
Fault message ID
704668554 0x2A00638A Description
CauseNew safety parameter set loaded
RemedyNew safety parameter set loaded
Severity/responseFor information only. No remedy necessary.
Information
-
Fault message ID
704668555 0x2A00638B Description
CauseMemory module - Access error
RemedyError accessing the safe parameter set on the SD card.
Severity/responseReset safe parameter set in the device. Reload safe parameter set.
Warning
-
Fault message ID
704668556 0x2A00638C Description
CauseDifferent safety parameter sets
RemedyThe safe parameter sets on the SD card and in the device are different.
Severity/responseLoad a safe parameter set from the SD card into the device. Acknowledge modification with confirmation button S82.
Warning
-
Fault message ID
704668557 0x2A00638D Description
CauseExtended Safety - No safety parameter set
RemedyNo safe parameter set was found in the device.
Severity/responseLoad safe parameter set into the device. Acknowledge modification with confirmation button S82.
Warning
-
Fault message ID
704668558 0x2A00638E Description
CauseExtended Safety - Safety parameter set defect
RemedyThe safe parameter set in the device is faulty.
Severity/responseLoad safe parameter set into the device. Acknowledge modification with confirmation button S82.
Warning
-
Fault message ID
704668559 0x2A00638F Description
CauseSafety parameter set - Format error
RemedyFormat error in the safe parameter set
Severity/responseReset the safe parameter set in the device and load it again. Acknowledge modification with confirmation button S82.
Warning
-
Fault message ID
704668560 0x2A006390 Description
CauseSafety parameter set - Plausibility error
RemedyThe set safety parameters are not plausible.
Severity/response1.Determine the error number in 0x2115:005 and analyze it using the table of plausibility errors. 2.Correct error. 3.Reload safe parameter set. 4.Acknowledge modification with confirmation button S82.
Warning
-
Fault message ID
704668561 0x2A006391 Description
CauseSafety parameter set - Communication error
RemedyA communication error has occurred while loading the safe parameter set.
Severity/response- Check communication settings.
- Check SD card.
- Reload safe parameter set. Acknowledge modification with confirmation button S82.
Warning
-
Fault message ID
704668562 0x2A006392 Description
CauseDifferent safety addresses detected
RemedyThe safety addresses in the device and on the SD card are different.
Severity/response- Adapt safety addresses.
- Reload safe parameter set. Acknowledge modification with confirmation button S82.
Warning
-
Fault message ID
704668563 0x2A006393 Description
CauseSSM - Wrong PDO version
RemedySafe speed monitoring is faulty because the PDO version of the data protocol is incompatible.
Severity/responseOnly devices with firmware > V1.0 support Extended Safety.
Warning
-
Fault message ID
704668564 0x2A006394 Description
CauseMemory module release information - access error
RemedyNo release information is available on the memory module.
Severity/responseAfter transferring an application with the "Application Loader", the release information for the safe parameter set must be generated separately for each device with the »EASY Starter« or »PLC Designer« via the +Safety parameter list+ and transferred to the device. After transmission, the safe parameter set must be saved in the device using the "Save" command.
Information
-
Fault message ID
704676234 0x2A00818A Description
CausePROFIsafe passivated
RemedyError in the PROFIsafe communication PROFIsafe was passivated.
Severity/responseCheck PROFIsafe component. Check network cable. Analyze the error history of the higher-level controller.
Information
-
Fault message ID
704676235 0x2A00818B Description
CausePROFIsafe has left data exchange
RemedyError in the PROFIsafe communication PROFIsafe has left data exchange.
Severity/responseCheck PROFIsafe component. Check network cable. Analyze the error history of the higher-level controller.
Information
-
Fault message ID
704676237 0x2A00818D Description
CausePROFIsafe - CRC1 error
RemedyThe F-Parameter-CRC is faulty.
Severity/responseCheck F-Parameter-CRC (CRC1) in the higher- level controller. Check device description file (GSDML).
Information
-
Fault message ID
704676238 0x2A00818E Description
Severity/responsePROFIsafe - Device specific error
Information
-
Fault message ID
704676239 0x2A00818F Description
Severity/responseiParameters - Saving, watchdog expired
Information
-
Fault message ID
704676245 0x2A008195 Description
CauseFSoE - Unexpected command
RemedyUnexpected FSoE command received.
Severity/responseCheck FSoE configuration. Restart communication.
Information
-
Fault message ID
704676246 0x2A008196 Description
CauseFSoE - Unknown command
RemedyUnknown FSoE command received.
Severity/responseCheck FSoE configuration. Restart communication.
Information
-
Fault message ID
704676247 0x2A008197 Description
CauseFSoE - Invalid connection ID
RemedyFSoE frame with invalid connection ID received.
Severity/responseCheck FSoE configuration. Restart communication.
Information
-
Fault message ID
704676248 0x2A008198 Description
CauseFSoE - CRC error
RemedyThe check of the CRC in the FSoE frames reports errors.
Severity/responseCheck FSoE configuration. Restart communication.
Information
-
Fault message ID
704676249 0x2A008199 Description
CauseFSoE - Watchdog expired
RemedyFSoE watchdog elapsed.
Severity/responseCheck set watchdog time in FSoE master and adapt if necessary.
Information
-
Fault message ID
704676252 0x2A00819C Description
CauseFSoE - Invalid communication parameter data
RemedyInvalid communication parameter data received.
Severity/responseCheck setting of the communication parameters.
Information
-
Fault message ID
704676253 0x2A00819D Description
CauseFSoE - Invalid application parameter length
RemedyThe length of the application parameters transmitted by the FSoE master differs from the expected length.
Severity/responseCheck setting of the communication parameters.
Information
-
Fault message ID
704676254 0x2A00819E Description
CauseFSoE - Invalid application parameter data
RemedyInvalid application parameter data received.
Severity/responseCheck setting of the communication parameters.
Information
-
Fault message ID
704676255 0x2A00819F Description
CauseFSoE - Passivated
RemedyDue to an error, FSoE was passivated.
Severity/responseCheck FSoE configuration. Reset error.
Information
-
0x2871:034
Parameter
Safety interface bits: SLS2 observed Data type
BOOLEAN Default setting
- (Read only) Attributes
- -
0x2871:035
Parameter
Safety interface bits: SLS3 observed Data type
BOOLEAN Default setting
- (Read only) Attributes
- -
0x2871:036
Parameter
Safety interface bits: SLS4 observed Data type
BOOLEAN Default setting
- (Read only) Attributes
- -
0x2871:037
Parameter
Safety interface bits: SMS observed Data type
BOOLEAN Default setting
- (Read only) Attributes
- -
0x2871:038
Parameter
Safety interface bits: SSM within limits Data type
BOOLEAN Default setting
- (Read only) Attributes
- -
0x2871:039
Parameter
Safety interface bits: SDIpos observed Data type
BOOLEAN Default setting
- (Read only) Attributes
- -
0x2871:040
Parameter
Safety interface bits: SDIneg observed Data type
BOOLEAN Default setting
- (Read only) Attributes
- -
0x2871:041
Parameter
Safety interface bits: SLP1 observed Data type
BOOLEAN Default setting
- (Read only) Attributes
- -
0x2871:042
Parameter
Safety interface bits: SLP2 observed Data type
BOOLEAN Default setting
- (Read only) Attributes
- -
0x2871:043
Parameter
Safety interface bits: SLP3 observed Data type
BOOLEAN Default setting
- (Read only) Attributes
- -
0x2871:044
Parameter
Safety interface bits: SLP4 observed Data type
BOOLEAN Default setting
- (Read only) Attributes
- -
0x2871:045
Parameter
Safety interface bits: SCA1 within limits Data type
BOOLEAN Default setting
- (Read only) Attributes
- -
0x2871:046
Parameter
Safety interface bits: SCA2 within limits Data type
BOOLEAN Default setting
- (Read only) Attributes
- -
0x2871:047
Parameter
Safety interface bits: SCA3 within limits Data type
BOOLEAN Default setting
- (Read only) Attributes
- -
0x2871:048
Parameter
Safety interface bits: SCA4 within limits Data type
BOOLEAN Default setting
- (Read only) Attributes
- -
0x2871:049
Parameter
Safety interface bits: PDSSpos observed Data type
BOOLEAN Default setting
- (Read only) Attributes
- -
0x2871:050
Parameter
Safety interface bits: PDSSneg observed Data type
BOOLEAN Default setting
- (Read only) Attributes
- -
0x2871:051
Parameter
Safety interface bits: SOS observed Data type
BOOLEAN Default setting
- (Read only) Attributes
- -
0x2871:052
Parameter
Safety interface bits: SBC activated Data type
BOOLEAN Default setting
- (Read only) Attributes
- -
0x2871:053
Parameter
Safety interface bits: SHom active Data type
BOOLEAN Default setting
- (Read only) Attributes
- -
0x2871:054
Parameter
Safety interface bits: SHom available Data type
BOOLEAN Default setting
- (Read only) Attributes
- -
0x2871:055
Parameter
Safety interface bits: Safe speed OK Data type
BOOLEAN Default setting
- (Read only) Attributes
- -
0x2871:056
Parameter
Safety interface bits: n=0 Data type
BOOLEAN Default setting
- (Read only) Attributes
- -
0x2871:057
Parameter
Safety interface bits: Positive direction Data type
BOOLEAN Default setting
- (Read only) Attributes
- -
0x2871:058
Parameter
Safety interface bits: Slip > 25% Data type
BOOLEAN Default setting
- (Read only) Attributes
-
No results.