i950
- Rated power 0.37 kW/0.5 HP
- Output current 2.4 A
- Output frequency 0-599 Hz
- Rated mains voltage 1/N(3)/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 0.55 kW/0.75 HP
- Output current 3.2 A
- Output frequency 0-599 Hz
- Rated mains voltage 1/N(3)/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 0.55 kW/0.75 HP
- Output current 1.8/1.6 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 0.75 kW/1 HP
- Output current 4.2 A
- Output frequency 0-599 Hz
- Rated mains voltage 1/N(3)/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 0.75 kW/1 HP
- Output current 2.4/2.1 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 1.5 kW/2 HP
- Output current 7 A
- Output frequency 0-599 Hz
- Rated mains voltage 1/N(3)/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 2.2 kW/3 HP
- Output current 9.6 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 2.2 kW/3 HP
- Output current 5.6/4.8 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 4 kW/5 HP
- Output current 16.5 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 4 kW/5 HP
- Output current 9.5/8.2 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 5.5 kW/7.5 HP
- Output current 23 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 7.5 kW/10 HP
- Output current 16.5/14 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 11 kW/15 HP
- Output current 23.5/21 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 15 kW/20 HP
- Output current 32/27 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 22 kW/30 HP
- Output current 47/40.4 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 30 kW/40 HP
- Output current 61/52 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 45 kW/60 HP
- Output current 89/77 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 55 kW/75 HP
- Output current 110/96 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 75 kW/100 HP
- Output current 150/124 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 90 kW/125 HP
- Output current 180/156 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 110 kW/150 HP
- Output current 212/180 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
-
Fault message ID
671158529 0x28011101 Description
CauseInitialization - Parameter value could not be written
RemedyInitialization - Parameter value could not be written
Severity/responseFor information only. No remedy necessary.
Information
-
Fault message ID
671158530 0x28011102 Description
CauseLoad default setting - Parameter value could not be written
RemedyWrite access denied with corresponding error message.
Severity/responseEvaluate parameter value based on the error message in the logbook. Correct parameter value accordingly.
Warning
-
Fault message ID
671158785 0x28011201 Description
CauseParameters - Initialization failed
RemedyNot all parameters could be initialized.
Severity/responseSee related entries in the logbook.
Warning
-
Fault message ID
671158786 0x28011202 Description
CauseParameters - Loading default values failed
RemedyNot all presets could be written.
Severity/responseSee related entries in the logbook.
Warning
-
Fault message ID
671158787 0x28011203 Description
CauseParameters - Loading TA default values failed
RemedyNot all presets of the technology application could be written.
Severity/responseSee related entries in the logbook.
Warning
-
Fault message ID
671159298 0x28011402 Description
CauseOpening the parameter description failed
RemedyParameter description is missing or faulty.
Severity/responseUpdate boot project or device firmware.
Fault
-
Fault message ID
671159299 0x28011403 Description
CauseOpening the parameter set failed
RemedyParameter set file is missing or faulty.
Severity/responseUpdate boot project or restart device.
Fault
-
Fault message ID
671219713 0x28020001 Description
CauseLogbook: Corrupt restore data
RemedyLogbook: Corrupt restore data
Severity/responseFor information only. No remedy necessary.
Information
-
Fault message ID
671219773 0x2802003D Description
CauseLogbook cleared
RemedyLogbook cleared
Severity/responseFor information only. No remedy necessary.
Information
-
Fault message ID
671219776 0x28020040 Description
CauseLogbook: Timeout restoring data
RemedyLogbook: Timeout restoring data
Severity/responseFor information only. No remedy necessary.
Information
-
Fault message ID
671219777 0x28020041 Description
CauseLogbook: Error restoring data
RemedyLogbook: Error restoring data
Severity/responseFor information only. No remedy necessary.
Information
-
Fault message ID
671219778 0x28020042 Description
CauseFirst boot with this firmware version
RemedyFirst boot with this firmware version
Severity/responseFor information only. No remedy necessary.
Information
-
Fault message ID
671219779 0x28020043 Description
CauseLogbook was restored.
RemedyLogbook was restored.
Severity/responseFor information only. No remedy necessary.
Information
-
Fault message ID
671219780 0x28020044 Description
CauseLogbook: Error reading persistent data.
RemedyLogbook: Error reading persistent data.
Severity/responseFor information only. No remedy necessary.
Information
-
Fault message ID
671263317 0x2802AA55 Description
CauseThe chronology of the logbook is not consistent
RemedyThe chronology of the logbook is not consistent
Severity/responseFor information only. No remedy necessary.
Information
-
Fault message ID
671354881 0x28041001 Description
CauseCmpLenzeErrorManagementAccess loaded without errors
RemedyCmpLenzeErrorManagementAccess loaded without errors
Severity/responseFor information only. No remedy necessary.
Information
-
Fault message ID
671420673 0x28051101 Description
CauseTest-Mode - More Application Credit required, application is starting delayed
RemedyThe "Application-Credit" is not sufficient for the application. The start of the application is delayed.
Severity/responseUse SD card with sufficient "Application-Credit".
Warning
-
Fault message ID
671420674 0x28051102 Description
CauseApplication-Credit - Invalid license data
RemedyFaulty license data was detected when the "Application-Credit" was loaded.
Severity/responseUse SD card with valid license data.
Warning
-
Fault message ID
671420675 0x28051103 Description
CauseApplication-Credit - License data missing
RemedyNo license data was found on the SD card when then the "Application-Credit" was loaded.
Severity/responseUse SD card with valid license data.
Warning
-
Fault message ID
671421185 0x28051301 Description
CauseBoot application - More Application Credit required
RemedyThe "Application-Credit" is not sufficient for the boot application. Booting is delayed.
Severity/responseUse SD card with sufficient "Application-Credit".
Warning
-
Fault message ID
671809799 0x280B0107 Description
CauseApplication was downloaded.
RemedyApplication was downloaded.
Severity/responseFor information only. No remedy necessary.
Information
-
Fault message ID
704663680 0x2A005080 Description
CauseInternal error - AIS
RemedyInternal error
Severity/responseRestart the device. If the error persists, replace the device.
Warning
-
Fault message ID
704663681 0x2A005081 Description
CauseInternal error - AIE
RemedyInternal error
Severity/responseRestart the device. If the error persists, replace the device.
Warning
-
Fault message ID
704663682 0x2A005082 Description
CauseInternal error - Button S82
RemedyInternal error
Severity/responseRestart the device. If the error persists, replace the device.
Warning
-
Fault message ID
704663683 0x2A005083 Description
CauseIRS - Internal error
RemedyInternal error
Severity/responseRestart the device. If the error persists, replace the device.
Warning
-
0x2C62:002
Parameter
Pole position identification (min. movement) settings: Ramp time Data type
U16 Default setting
10 s Attributes
C -
0x2C62:003
Parameter
Pole position identification (min. movement) settings: Gain Data type
U16 Default setting
0 % Attributes
- -
0x2C62:004
Parameter
Pole position identification (min. movement) settings: Reset time Data type
U16 Default setting
62.5 ms Attributes
- -
0x2C62:005
Parameter
Pole position identification (min. movement) settings: Max. move permitted Data type
U8 Default setting
20 ° Attributes
- -
0x2C62:006
Parameter
Pole position identification (min. movement) settings: Absolute current amplitude Data type
U32 Default setting
x.xx A (Read only) Attributes
- -
0x2C63:001
Parameter
PPI without movement: Execution Data type
U8 Default setting
Disabled [0] Attributes
C -
0x2C63:002
Parameter
PPI without movement: Current adjust factor Data type
U16 Default setting
100 % Attributes
C -
0x2C64:001
Parameter
Cable Check: Behavior after switch on Data type
U8 Default setting
No action [0] Attributes
C -
0x2C64:002
Parameter
Cable Check: Status word Data type
U16 Default setting
- (Read only) Attributes
H -
0x2C65:001
Parameter
PPI validation: Activation Data type
U8 Default setting
Off [0] Attributes
C -
0x2C65:002
Parameter
PPI validation: Settings Data type
U8 Default setting
No action [0] Attributes
- -
0x2C65:003
Parameter
PPI validation: Status Data type
U16 Default setting
- (Read only) Attributes
H -
0x2C65:004
Parameter
PPI validation: Pole position set value Data type
I16 Default setting
0.0 ° Attributes
- -
0x2C66:001
Parameter
PPI mode for 0x6060: Selection Data type
U8 Default setting
PPI 360° [1] Attributes
C -
0x2C67:001
Parameter
MOL settings for 0x6060: Current setpoint 1 Data type
U16 Default setting
71 % Attributes
- -
0x2C67:002
Parameter
MOL settings for 0x6060: Frequency 1 Data type
I16 Default setting
1.0 Hz Attributes
- -
0x2C67:003
Parameter
MOL settings for 0x6060: Current 1 - ramp time Data type
U16 Default setting
10 ms Attributes
- -
0x2C67:004
Parameter
MOL settings for 0x6060: Frequency 1 - ramp time Data type
U16 Default setting
200 ms Attributes
- -
0x2C67:005
Parameter
MOL settings for 0x6060: Starting angle 1 Data type
I16 Default setting
0.0 ° Attributes
- -
0x2C67:006
Parameter
MOL settings for 0x6060: Stopping time 1 Data type
U32 Default setting
10000.0 s Attributes
C -
0x2C67:011
Parameter
MOL settings for 0x6060: Current setpoint 2 Data type
U16 Default setting
71 % Attributes
- -
0x2C67:012
Parameter
MOL settings for 0x6060: Frequency 2 Data type
I16 Default setting
5.0 Hz Attributes
- -
0x2C67:013
Parameter
MOL settings for 0x6060: Current 2 - ramp time Data type
U16 Default setting
10 ms Attributes
- -
0x2C67:014
Parameter
MOL settings for 0x6060: Frequency 2 - ramp time Data type
U16 Default setting
1000 ms Attributes
- -
0x2C67:015
Parameter
MOL settings for 0x6060: Starting angle 2 Data type
I16 Default setting
0.0 ° Attributes
-
No results.