i950
- Rated power 0.37 kW/0.5 HP
- Output current 2.4 A
- Output frequency 0-599 Hz
- Rated mains voltage 1/N(3)/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 0.55 kW/0.75 HP
- Output current 3.2 A
- Output frequency 0-599 Hz
- Rated mains voltage 1/N(3)/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 0.55 kW/0.75 HP
- Output current 1.8/1.6 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 0.75 kW/1 HP
- Output current 4.2 A
- Output frequency 0-599 Hz
- Rated mains voltage 1/N(3)/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 0.75 kW/1 HP
- Output current 2.4/2.1 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 1.5 kW/2 HP
- Output current 7 A
- Output frequency 0-599 Hz
- Rated mains voltage 1/N(3)/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 2.2 kW/3 HP
- Output current 9.6 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 2.2 kW/3 HP
- Output current 5.6/4.8 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 4 kW/5 HP
- Output current 16.5 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 4 kW/5 HP
- Output current 9.5/8.2 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 5.5 kW/7.5 HP
- Output current 23 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 7.5 kW/10 HP
- Output current 16.5/14 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 11 kW/15 HP
- Output current 23.5/21 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 15 kW/20 HP
- Output current 32/27 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 22 kW/30 HP
- Output current 47/40.4 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 30 kW/40 HP
- Output current 61/52 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 45 kW/60 HP
- Output current 89/77 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 55 kW/75 HP
- Output current 110/96 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 75 kW/100 HP
- Output current 150/124 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 90 kW/125 HP
- Output current 180/156 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 110 kW/150 HP
- Output current 212/180 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
-
Fault message ID
671158529 0x28011101 Description
CauseInitialization - Parameter value could not be written
RemedyInitialization - Parameter value could not be written
Severity/responseFor information only. No remedy necessary.
Information
-
Fault message ID
671158530 0x28011102 Description
CauseLoad default setting - Parameter value could not be written
RemedyWrite access denied with corresponding error message.
Severity/responseEvaluate parameter value based on the error message in the logbook. Correct parameter value accordingly.
Warning
-
Fault message ID
671158785 0x28011201 Description
CauseParameters - Initialization failed
RemedyNot all parameters could be initialized.
Severity/responseSee related entries in the logbook.
Warning
-
Fault message ID
671158786 0x28011202 Description
CauseParameters - Loading default values failed
RemedyNot all presets could be written.
Severity/responseSee related entries in the logbook.
Warning
-
Fault message ID
671158787 0x28011203 Description
CauseParameters - Loading TA default values failed
RemedyNot all presets of the technology application could be written.
Severity/responseSee related entries in the logbook.
Warning
-
Fault message ID
671159298 0x28011402 Description
CauseOpening the parameter description failed
RemedyParameter description is missing or faulty.
Severity/responseUpdate boot project or device firmware.
Fault
-
Fault message ID
671159299 0x28011403 Description
CauseOpening the parameter set failed
RemedyParameter set file is missing or faulty.
Severity/responseUpdate boot project or restart device.
Fault
-
Fault message ID
671219713 0x28020001 Description
CauseLogbook: Corrupt restore data
RemedyLogbook: Corrupt restore data
Severity/responseFor information only. No remedy necessary.
Information
-
Fault message ID
671219773 0x2802003D Description
CauseLogbook cleared
RemedyLogbook cleared
Severity/responseFor information only. No remedy necessary.
Information
-
Fault message ID
671219776 0x28020040 Description
CauseLogbook: Timeout restoring data
RemedyLogbook: Timeout restoring data
Severity/responseFor information only. No remedy necessary.
Information
-
Fault message ID
671219777 0x28020041 Description
CauseLogbook: Error restoring data
RemedyLogbook: Error restoring data
Severity/responseFor information only. No remedy necessary.
Information
-
Fault message ID
671219778 0x28020042 Description
CauseFirst boot with this firmware version
RemedyFirst boot with this firmware version
Severity/responseFor information only. No remedy necessary.
Information
-
Fault message ID
671219779 0x28020043 Description
CauseLogbook was restored.
RemedyLogbook was restored.
Severity/responseFor information only. No remedy necessary.
Information
-
Fault message ID
671219780 0x28020044 Description
CauseLogbook: Error reading persistent data.
RemedyLogbook: Error reading persistent data.
Severity/responseFor information only. No remedy necessary.
Information
-
Fault message ID
671263317 0x2802AA55 Description
CauseThe chronology of the logbook is not consistent
RemedyThe chronology of the logbook is not consistent
Severity/responseFor information only. No remedy necessary.
Information
-
Fault message ID
671354881 0x28041001 Description
CauseCmpLenzeErrorManagementAccess loaded without errors
RemedyCmpLenzeErrorManagementAccess loaded without errors
Severity/responseFor information only. No remedy necessary.
Information
-
Fault message ID
671420673 0x28051101 Description
CauseTest-Mode - More Application Credit required, application is starting delayed
RemedyThe "Application-Credit" is not sufficient for the application. The start of the application is delayed.
Severity/responseUse SD card with sufficient "Application-Credit".
Warning
-
Fault message ID
671420674 0x28051102 Description
CauseApplication-Credit - Invalid license data
RemedyFaulty license data was detected when the "Application-Credit" was loaded.
Severity/responseUse SD card with valid license data.
Warning
-
Fault message ID
671420675 0x28051103 Description
CauseApplication-Credit - License data missing
RemedyNo license data was found on the SD card when then the "Application-Credit" was loaded.
Severity/responseUse SD card with valid license data.
Warning
-
Fault message ID
671421185 0x28051301 Description
CauseBoot application - More Application Credit required
RemedyThe "Application-Credit" is not sufficient for the boot application. Booting is delayed.
Severity/responseUse SD card with sufficient "Application-Credit".
Warning
-
Fault message ID
671809799 0x280B0107 Description
CauseApplication was downloaded.
RemedyApplication was downloaded.
Severity/responseFor information only. No remedy necessary.
Information
-
Fault message ID
704663680 0x2A005080 Description
CauseInternal error - AIS
RemedyInternal error
Severity/responseRestart the device. If the error persists, replace the device.
Warning
-
Fault message ID
704663681 0x2A005081 Description
CauseInternal error - AIE
RemedyInternal error
Severity/responseRestart the device. If the error persists, replace the device.
Warning
-
Fault message ID
704663682 0x2A005082 Description
CauseInternal error - Button S82
RemedyInternal error
Severity/responseRestart the device. If the error persists, replace the device.
Warning
-
Fault message ID
704663683 0x2A005083 Description
CauseIRS - Internal error
RemedyInternal error
Severity/responseRestart the device. If the error persists, replace the device.
Warning
-
0x2879:001
Parameter
Mechanical data: Motor mounting direction Data type
U8 Default setting
Motor rotating CW [0] Attributes
- -
0x287A:001
Parameter
Safety load encoder: System Data type
U8 Default setting
No load encoder [0] Attributes
- -
0x287A:003
Parameter
Safety load encoder: Gear numerator Data type
U16 Default setting
100 Attributes
- -
0x287A:004
Parameter
Safety load encoder: Gear denominator Data type
U16 Default setting
100 Attributes
- -
0x287A:005
Parameter
Safety load encoder: Mounting direction Data type
U8 Default setting
As motor encoder [0] Attributes
- -
0x287A:006
Parameter
Safety load encoder: Position Data type
I32 Default setting
0 incr. Attributes
- -
0x287A:007
Parameter
Safety load encoder: Position status Data type
U8 Default setting
Invalid [0] Attributes
- -
0x287A:008
Parameter
Safety load encoder: Additional gear numerator Data type
U32 Default setting
1 Attributes
- -
0x287A:009
Parameter
Safety load encoder: Additional gear denominator Data type
U32 Default setting
1 Attributes
- -
0x287B:001
Parameter
Speed: Tolerance window (n=0) Data type
U16 Default setting
5 rpm Attributes
- -
0x287B:002
Parameter
Speed: Tolerance speed comparison Data type
U16 Default setting
20 rpm Attributes
- -
0x287B:003
Parameter
Speed: Current speed n_safe Data type
I16 Default setting
x rpm (Read only) Attributes
- -
0x287B:004
Parameter
Speed: Internal current speed nSD Data type
I16 Default setting
x rpm (Read only) Attributes
- -
0x287B:005
Parameter
Speed: Internal current speed nBD Data type
I16 Default setting
x rpm (Read only) Attributes
- -
0x287B:006
Parameter
Speed: Current speed difference nSD-nBD Data type
I16 Default setting
x rpm (Read only) Attributes
- -
0x287C:001
Parameter
Position: Tolerance position comparison Data type
I32 Default setting
8192 incr. Attributes
- -
0x287C:002
Parameter
Position: Current position p_safe Data type
I32 Default setting
x incr. (Read only) Attributes
- -
0x287C:003
Parameter
Position: Internal current position pSD Data type
I32 Default setting
x incr. (Read only) Attributes
- -
0x287C:004
Parameter
Position: Internal current position pBD Data type
I32 Default setting
x incr. (Read only) Attributes
- -
0x287C:005
Parameter
Position: Current position difference pSD-pBD Data type
I32 Default setting
x incr. (Read only) Attributes
- -
0x2880:001
Parameter
SHom_Start: Source Data type
U8 Default setting
Disabled [0] Attributes
- -
0x2880:002
Parameter
SHom_Start: IRS edge trigger Data type
U8 Default setting
Rising edge [0] Attributes
- -
0x2881:001
Parameter
SHom_Load: Source Data type
U8 Default setting
IRL [15] Attributes
- -
0x2881:002
Parameter
SHom_Load: IRL edge trigger Data type
U8 Default setting
Rising edge [0] Attributes
- -
0x2882:001
Parameter
SHom: Home position Data type
I32 Default setting
0 incr. Attributes
-