i950
- Rated power 0.37 kW/0.5 HP
- Output current 2.4 A
- Output frequency 0-599 Hz
- Rated mains voltage 1/N(3)/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 0.55 kW/0.75 HP
- Output current 3.2 A
- Output frequency 0-599 Hz
- Rated mains voltage 1/N(3)/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 0.55 kW/0.75 HP
- Output current 1.8/1.6 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 0.75 kW/1 HP
- Output current 4.2 A
- Output frequency 0-599 Hz
- Rated mains voltage 1/N(3)/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 0.75 kW/1 HP
- Output current 2.4/2.1 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 1.5 kW/2 HP
- Output current 7 A
- Output frequency 0-599 Hz
- Rated mains voltage 1/N(3)/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 2.2 kW/3 HP
- Output current 9.6 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 2.2 kW/3 HP
- Output current 5.6/4.8 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 4 kW/5 HP
- Output current 16.5 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 4 kW/5 HP
- Output current 9.5/8.2 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 5.5 kW/7.5 HP
- Output current 23 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 7.5 kW/10 HP
- Output current 16.5/14 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 11 kW/15 HP
- Output current 23.5/21 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 15 kW/20 HP
- Output current 32/27 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 22 kW/30 HP
- Output current 47/40.4 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 30 kW/40 HP
- Output current 61/52 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 45 kW/60 HP
- Output current 89/77 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 55 kW/75 HP
- Output current 110/96 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 75 kW/100 HP
- Output current 150/124 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 90 kW/125 HP
- Output current 180/156 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 110 kW/150 HP
- Output current 212/180 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
-
Fault message ID
671158529 0x28011101 Description
CauseInitialization - Parameter value could not be written
RemedyInitialization - Parameter value could not be written
Severity/responseFor information only. No remedy necessary.
Information
-
Fault message ID
671158530 0x28011102 Description
CauseLoad default setting - Parameter value could not be written
RemedyWrite access denied with corresponding error message.
Severity/responseEvaluate parameter value based on the error message in the logbook. Correct parameter value accordingly.
Warning
-
Fault message ID
671158785 0x28011201 Description
CauseParameters - Initialization failed
RemedyNot all parameters could be initialized.
Severity/responseSee related entries in the logbook.
Warning
-
Fault message ID
671158786 0x28011202 Description
CauseParameters - Loading default values failed
RemedyNot all presets could be written.
Severity/responseSee related entries in the logbook.
Warning
-
Fault message ID
671158787 0x28011203 Description
CauseParameters - Loading TA default values failed
RemedyNot all presets of the technology application could be written.
Severity/responseSee related entries in the logbook.
Warning
-
Fault message ID
671159298 0x28011402 Description
CauseOpening the parameter description failed
RemedyParameter description is missing or faulty.
Severity/responseUpdate boot project or device firmware.
Fault
-
Fault message ID
671159299 0x28011403 Description
CauseOpening the parameter set failed
RemedyParameter set file is missing or faulty.
Severity/responseUpdate boot project or restart device.
Fault
-
Fault message ID
671219713 0x28020001 Description
CauseLogbook: Corrupt restore data
RemedyLogbook: Corrupt restore data
Severity/responseFor information only. No remedy necessary.
Information
-
Fault message ID
671219773 0x2802003D Description
CauseLogbook cleared
RemedyLogbook cleared
Severity/responseFor information only. No remedy necessary.
Information
-
Fault message ID
671219776 0x28020040 Description
CauseLogbook: Timeout restoring data
RemedyLogbook: Timeout restoring data
Severity/responseFor information only. No remedy necessary.
Information
-
Fault message ID
671219777 0x28020041 Description
CauseLogbook: Error restoring data
RemedyLogbook: Error restoring data
Severity/responseFor information only. No remedy necessary.
Information
-
Fault message ID
671219778 0x28020042 Description
CauseFirst boot with this firmware version
RemedyFirst boot with this firmware version
Severity/responseFor information only. No remedy necessary.
Information
-
Fault message ID
671219779 0x28020043 Description
CauseLogbook was restored.
RemedyLogbook was restored.
Severity/responseFor information only. No remedy necessary.
Information
-
Fault message ID
671219780 0x28020044 Description
CauseLogbook: Error reading persistent data.
RemedyLogbook: Error reading persistent data.
Severity/responseFor information only. No remedy necessary.
Information
-
Fault message ID
671263317 0x2802AA55 Description
CauseThe chronology of the logbook is not consistent
RemedyThe chronology of the logbook is not consistent
Severity/responseFor information only. No remedy necessary.
Information
-
Fault message ID
671354881 0x28041001 Description
CauseCmpLenzeErrorManagementAccess loaded without errors
RemedyCmpLenzeErrorManagementAccess loaded without errors
Severity/responseFor information only. No remedy necessary.
Information
-
Fault message ID
671420673 0x28051101 Description
CauseTest-Mode - More Application Credit required, application is starting delayed
RemedyThe "Application-Credit" is not sufficient for the application. The start of the application is delayed.
Severity/responseUse SD card with sufficient "Application-Credit".
Warning
-
Fault message ID
671420674 0x28051102 Description
CauseApplication-Credit - Invalid license data
RemedyFaulty license data was detected when the "Application-Credit" was loaded.
Severity/responseUse SD card with valid license data.
Warning
-
Fault message ID
671420675 0x28051103 Description
CauseApplication-Credit - License data missing
RemedyNo license data was found on the SD card when then the "Application-Credit" was loaded.
Severity/responseUse SD card with valid license data.
Warning
-
Fault message ID
671421185 0x28051301 Description
CauseBoot application - More Application Credit required
RemedyThe "Application-Credit" is not sufficient for the boot application. Booting is delayed.
Severity/responseUse SD card with sufficient "Application-Credit".
Warning
-
Fault message ID
671809799 0x280B0107 Description
CauseApplication was downloaded.
RemedyApplication was downloaded.
Severity/responseFor information only. No remedy necessary.
Information
-
Fault message ID
704663680 0x2A005080 Description
CauseInternal error - AIS
RemedyInternal error
Severity/responseRestart the device. If the error persists, replace the device.
Warning
-
Fault message ID
704663681 0x2A005081 Description
CauseInternal error - AIE
RemedyInternal error
Severity/responseRestart the device. If the error persists, replace the device.
Warning
-
Fault message ID
704663682 0x2A005082 Description
CauseInternal error - Button S82
RemedyInternal error
Severity/responseRestart the device. If the error persists, replace the device.
Warning
-
Fault message ID
704663683 0x2A005083 Description
CauseIRS - Internal error
RemedyInternal error
Severity/responseRestart the device. If the error persists, replace the device.
Warning
-
0x2836:003
Parameter
Manual control mode: Ramp time (current) Data type
U16 Default setting
0 ms Attributes
- -
0x2836:004
Parameter
Manual control mode: Ramp time (frequency) Data type
U16 Default setting
500 ms Attributes
- -
0x2836:005
Parameter
Manual control mode: Time monitoring (frequency) Data type
U32 Default setting
2500 ms Attributes
- -
0x2836:006
Parameter
Manual control mode: Current controller gain Data type
U32 Default setting
20.00 V/A Attributes
- -
0x2836:007
Parameter
Manual control mode: Current controller reset time Data type
U32 Default setting
20.00 ms Attributes
- -
0x2840
Parameter
Error reset time Data type
I32 Default setting
x ms (Read only) Attributes
- -
0x2841
Parameter
Reset error Data type
U8 Default setting
0 Attributes
- -
0x284E:001
Parameter
Additional error information: Component ID Data type
U16 Default setting
- (Read only) Attributes
- -
0x284F
Parameter
Current error Data type
OCTET[64] Default setting
- (Read only) Attributes
- -
0x2857:001
Parameter
CANopen monitoring: RPDO1-Timeout Data type
U8 Default setting
Warning [2] Attributes
- -
0x2857:002
Parameter
CANopen monitoring: RPDO2-Timeout Data type
U8 Default setting
Warning [2] Attributes
- -
0x2857:003
Parameter
CANopen monitoring: RPDO3-Timeout Data type
U8 Default setting
Warning [2] Attributes
- -
0x2857:004
Parameter
CANopen monitoring: RPDO4-Timeout Data type
U8 Default setting
Warning [2] Attributes
- -
0x2857:005
Parameter
CANopen monitoring: Heartbeat-Timeout Consumer 1 Data type
U8 Default setting
Warning [2] Attributes
- -
0x2857:006
Parameter
CANopen monitoring: Heartbeat-Timeout Consumer 2 Data type
U8 Default setting
Warning [2] Attributes
- -
0x2857:007
Parameter
CANopen monitoring: Heartbeat-Timeout Consumer 3 Data type
U8 Default setting
Warning [2] Attributes
- -
0x2857:008
Parameter
CANopen monitoring: Heartbeat-Timeout Consumer 4 Data type
U8 Default setting
Warning [2] Attributes
- -
0x2857:010
Parameter
CANopen monitoring: "Bus-off" state change Data type
U8 Default setting
Warning [2] Attributes
- -
0x2857:011
Parameter
CANopen monitoring: Warning Data type
U8 Default setting
Warning [2] Attributes
- -
0x2859:001
Parameter
Network monitoring: Watchdog elapsed Data type
U8 Default setting
Warning [2] Attributes
- -
0x2859:002
Parameter
Network monitoring: Data exchange exited Data type
U8 Default setting
No response [0] Attributes
- -
0x2859:003
Parameter
Network monitoring: Invalid configuration Data type
U8 Default setting
Warning [2] Attributes
- -
0x2859:004
Parameter
Network monitoring: Initialisation error Data type
U8 Default setting
Warning [2] Attributes
- -
0x2859:005
Parameter
Network monitoring: Invalid process data Data type
U8 Default setting
Warning [2] Attributes
- -
0x2859:006
Parameter
Network monitoring: Time-out explicit message Data type
U8 Default setting
Warning [2] Attributes
-