i950
- Rated power 0.37 kW/0.5 HP
- Output current 2.4 A
- Output frequency 0-599 Hz
- Rated mains voltage 1/N(3)/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 0.55 kW/0.75 HP
- Output current 3.2 A
- Output frequency 0-599 Hz
- Rated mains voltage 1/N(3)/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 0.55 kW/0.75 HP
- Output current 1.8/1.6 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 0.75 kW/1 HP
- Output current 4.2 A
- Output frequency 0-599 Hz
- Rated mains voltage 1/N(3)/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 0.75 kW/1 HP
- Output current 2.4/2.1 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 1.5 kW/2 HP
- Output current 7 A
- Output frequency 0-599 Hz
- Rated mains voltage 1/N(3)/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 2.2 kW/3 HP
- Output current 9.6 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 2.2 kW/3 HP
- Output current 5.6/4.8 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 4 kW/5 HP
- Output current 16.5 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 4 kW/5 HP
- Output current 9.5/8.2 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 5.5 kW/7.5 HP
- Output current 23 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 7.5 kW/10 HP
- Output current 16.5/14 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 11 kW/15 HP
- Output current 23.5/21 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 15 kW/20 HP
- Output current 32/27 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 22 kW/30 HP
- Output current 47/40.4 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 30 kW/40 HP
- Output current 61/52 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 45 kW/60 HP
- Output current 89/77 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 55 kW/75 HP
- Output current 110/96 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 75 kW/100 HP
- Output current 150/124 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 90 kW/125 HP
- Output current 180/156 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 110 kW/150 HP
- Output current 212/180 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
-
Fault message ID
822313370 0x3103819A Description
CauseNetwork - Initialization with safety option failed
RemedyCommunication with the safety option could not be initialized correctly.
Severity/responseCheck safe parameter set.
Information
-
Fault message ID
822313371 0x3103819B Description
CauseNetwork - Communication time-out with safety option
RemedyCommunication with the safety option is disturbed.
Severity/responseCheck status of the safety option.
Information
-
Fault message ID
822313607 0x31038287 Description
CauseNetwork - Invalid configuration
RemedyNetwork configuration is faulty.
Severity/responseCheck network configuration.
Warning (configurable)
Setting parameters: 0x2859:003
-
Fault message ID
822313620 0x31038294 Description
CauseCAN: RPDO4 time-out
Severity/responseRPDO4 was not received within the time-out period set in 0x2304:075 or with the sync configured.
Warning (configurable)
Setting parameters: 0x2857:004
-
Fault message ID
12816 0x3210 Description
Keypad displayFault - DC bus overvoltage
DC Bus OV Cause
RemedyDC-bus voltage has exceeded the error threshold for overvoltage due to a too high braking energy or a too high mains voltage. The error threshold (display in 0x2540:006 (P208.06) results from the setting of the rated mains voltage in 0x2540:001 (P208.01).
Severity/responseReduce dynamic performance of the load profile.
Check mains voltage.
Check settings for brake energy
management.0x2541:001 (P706.01) = [0]: Connect brake resistor to the power unit and activate the integrated brake chopper
Fault
-
Fault message ID
12832 0x3220 Description
Keypad displayFault - DC bus undervoltage
DC Bus UV Cause
RemedyDC-bus voltage has fallen below the error threshold for undervoltage. The error threshold (display in 0x2540:003 (P208.03)) results from the setting of the rated mains voltage in 0x2540:001 (P208.01).
Severity/response- Check mains voltage.
- 0x2D87 (P105.00)Check DC-bus voltage.
- Check mains settings.
- Check fuses.
Trouble
-
Fault message ID
16912 0x4210 Description
Keypad displayFault - Power unit overtemperature
PU Overtemp. Cause
RemedyThe heatsink temperature of the power unit (display in 0x2D84:001 (P117.01)) has exceeded the fixed error threshold (100 °C).
- Ambient temperature too high.
- Fan or ventilation slots are polluted.
- Fan is defective.
Severity/response- Check mains voltage.
- Provide for a sufficient cooling of the device. In case of a 100 % load, 60 C to +70°C are normal. Display of the heatsink temperature in 0x2D84:001 (P117.01).
- Clean fan and ventilation slots. If required, replace fan.
- Reduce switching frequency 0x2939 (P305.00)
Fault
-
Fault message ID
17024 0x4280 Description
Keypad displayFault - Heat sink temperature sensor
Heatsink sensor Cause
RemedySensor for the temperature monitoring of the power unit is defective. The failure of the temperature monitoring function poses the risk of overheating!
Severity/responseHardware error: it is necessary to contact the manufacturer, since the device must be replaced.
Fault
-
Fault message ID
17025 0x4281 Description
Keypad displayHeat sink fan warning
Heatsink fan Cause
RemedyWarning of the heatsink fan.
Severity/responseClean fan and ventilation slots. If required, replace fan. The fans can be unlocked via locking hooks and can then be removed.
Warning
-
Fault message ID
17168 0x4310 Description
Keypad displayMotor overtemperature
Overtemp. motor Cause
RemedyThe motor temperature sensor connected to terminals X109/T1 and X109/T2 measures a too high motor temperature.
- Motor too hot by impermissibly high currents.
- Motor too hot by frequent and too long acceleration processes.
Severity/response- Check drive dimensioning.
- Check motor temperature sensor and wiring.
Fault (configurable)
- The event can only be reset after a blocking time.
-
Fault message ID
20754 0x5112 Description
Keypad displayExternal supply voltage critical
Ext. supply low Cause
RemedyExternal supply voltage failed or too low.
Severity/response- Check optional external 24V voltage supply (terminal X3/24E), if connected.
- Check mains voltage.
Warning
-
Fault message ID
24970 0x618A Description
Keypad displayWarning - Internal fan
Internal fan Cause
RemedyWarning of the internal fan.
Severity/responseCheck/replace internal fan.
Warning
-
Fault message ID
28801 0x7081 Description
Keypad displayFault - Analog input 1
fault AI1 Cause
RemedyThe monitoring function of the input signal configured for analog input 1 in 0x2636:008 (P430.08) and 0x2636:009 (P430.09) has been triggered.
Severity/response- Check input signal at analog input 1.
- Check configuration of the monitoring function.
Fault (configurable) Setting parameters: 0x2636:010 (P430.10)
-
Fault message ID
28802 0x7082 Description
Keypad displayAnalog input 2 fault
AI2 fault Cause
RemedyThe monitoring function of the input signal configured for analog input 2 in 0x2637:008 (P431.08) and 0x2637:009 (P431.09) has been triggered.
Severity/response- Check input signal at analog input 2.
- Check configuration of the monitoring function.
Fault (configurable) Setting parameters: 0x2637:010 (P431.10)
-
Fault message ID
28961 0x7121 Description
Keypad displayFault - Pole position identification
Pole pos. error Cause
Remedy- Too many deviations during the pole position identification.
- Compared to the inverter, the rated motor current is too high or too low.
Severity/response- Check setting of the motor data.
- Ensure that the motor is at a standstill during the pole position identification process.
- Ensure that the motor and inverter match each other in terms of power.
Fault (configurable) Setting parameters: 0x2C60
-
Fault message ID
33042 0x8112 Description
Keypad displayNetwork - Time-out explicit message
TO expl. msg Cause
Remedy- Within the time-out period for explicit messages, which has been parameterised by the scanner, no "explicit message" was received.
- The connection to the scanner has been interrupted.
- Failure of an explicit connection.
Severity/response- Check cables and terminals.
- Plug network cables into the Ethernet port.
- Check the requested package interval (RPI) of the explicit connection.
- Increase time limit for explicit messages in the scanner.
Warning (configurable) Setting parameters: 0x2859:006 (P515.06)
-
Fault message ID
33044 0x8114 Description
Keypad displayNetwork - Overall communication time-out
TO overall comm Cause
Remedy- EtherNet/IP: the maximum permissible time- out period for the CIP communication set in 0x23A1:010 (P510.10) has been exceeded.
- Modbus TCP/IP: the maximum permissible time-out period for the TCP communication set in 0x23B1:010 (P510.10) has been exceeded.
Severity/response- Check cables and terminals.
- Connect network cable.
Warning (configurable)
-
Fault message ID
33154 0x8182 Description
Keypad displayCAN: bus off
CAN: bus off Cause
RemedyToo many faulty frames have been received.
- Defective cable (e. g. loose contact).
- Two nodes with the same node address.
Severity/response- Check wiring of the network.
- Check bus terminating resistor.
- Set the identical baud rate for each node of the network.
- Assign a unique node address to each node of the network.
- Eliminate EMC interferences.
Trouble (configurable)
- Change to the "Bus-Off" communication status.
-
Fault message ID
33155 0x8183 Description
Keypad displayCAN: warning
CAN bus warning Cause
RemedyToo many faulty frames have been received.
- Defective cable (e. g. loose contact).
- Two nodes with the same node address.
Severity/response- Check wiring of the network.
- Check bus terminating resistor.
- Set the identical baud rate for each node of the network.
- Assign a unique node address to each node of the network.
- Eliminate EMC interferences.
Warning (configurable)
-
Fault message ID
33156 0x8184 Description
Keypad displayCAN: heartbeat time-out consumer 1
CAN heartb. C1 Cause
RemedyWithin the heartbeat time 0x1016:001 (P520.01), no heartbeat telegram was received by node 1 to be monitored.
Severity/response- Check communication with the heartbeat producer.
- Reactivate heartbeat producer.
Fault (configurable)
-
Fault message ID
33157 0x8185 Description
Keypad displayCAN: heartbeat time-out consumer 2
CAN heartb. C2 Cause
RemedyWithin the heartbeat time 0x1016:002 (P520.02), no heartbeat telegram was received by node 2 to be monitored.
Severity/response- Check communication with the heartbeat producer.
- Reactivate heartbeat producer.
Fault (configurable)
-
Fault message ID
33158 0x8186 Description
Keypad displayCAN: heartbeat time-out consumer 3
CAN heartb. C3 Cause
RemedyWithin the heartbeat time 0x1016:003 (P520.03), no heartbeat telegram was received by node 3 to be monitored.
Severity/response- Check communication with the heartbeat producer.
- Reactivate heartbeat producer.
Fault (configurable)
-
Fault message ID
33159 0x8187 Description
Keypad displayCAN: heartbeat time-out consumer 4
CAN heartb. C4 Cause
RemedyWithin the heartbeat time 0x1016:004 (P520.04), no heartbeat telegram was received by node 4 to be monitored.
Severity/response- Check communication with the heartbeat producer.
- Reactivate heartbeat producer.
Fault (configurable)
-
Fault message ID
33168 0x8190 Description
Keypad displayNetwork - Watchdog time-out
Watchdog timeout Cause
RemedyTime-out during cyclic data reception, e.g. due to an interrupted communication link to the master or missing cyclic data.
Severity/response- Check wiring of the network.
- Eliminate EMC interferences.
Trouble (configurable)
-
Fault message ID
33169 0x8191 Description
Keypad displayNetwork - Disruption of cyclic data exchange
Cycl data error Cause
RemedyThe communication partner has interrupted the cyclic data exchange.
Severity/response- Check wiring of the network.
- The slave must receive new parameterisation and configuration files by the master, in order to be able to exchange data again.
No response (configurable)
-
0x28D9:002
Parameter
SCA: SCA2 - Upper position limit Data type
I32 Default setting
0 incr. Attributes
- -
0x28D9:003
Parameter
SCA: SCA3 - Upper position limit Data type
I32 Default setting
0 incr. Attributes
- -
0x28D9:004
Parameter
SCA: SCA4 - Upper position limit Data type
I32 Default setting
0 incr. Attributes
- -
0x28DA:001
Parameter
SCA: "SCA1 within limits" - Output Data type
U8 Default setting
Disabled [0] Attributes
- -
0x28DA:002
Parameter
SCA: "SCA2 within limits" - Output Data type
U8 Default setting
Disabled [0] Attributes
- -
0x28DA:003
Parameter
SCA: "SCA3 within limits" - Output Data type
U8 Default setting
Disabled [0] Attributes
- -
0x28DA:004
Parameter
SCA: "SCA4 within limits" - Output Data type
U8 Default setting
Disabled [0] Attributes
- -
0x28DC
Parameter
PDSS Source SD-In Data type
U8 Default setting
Disabled [0] Attributes
- -
0x28DD
Parameter
PDSS Source S-Bus Data type
U8 Default setting
Disabled [0] Attributes
- -
0x28DE:001
Parameter
PDSS: Permanent activation Data type
U8 Default setting
On demand [0] Attributes
- -
0x28DE:002
Parameter
PDSS: Lower position limit Data type
I32 Default setting
0 incr. Attributes
- -
0x28DE:003
Parameter
PDSS: Upper position limit Data type
I32 Default setting
0 incr. Attributes
- -
0x28DE:004
Parameter
PDSS: Lower SCS limit Data type
I32 Default setting
0 incr. Attributes
- -
0x28DE:005
Parameter
PDSS: Upper SCS limit Data type
I32 Default setting
0 incr. Attributes
- -
0x28DE:006
Parameter
PDSS: SCS from lower limit Data type
U16 Default setting
0 rpm Attributes
- -
0x28DE:007
Parameter
PDSS: SCS from upper limit Data type
U16 Default setting
0 rpm Attributes
- -
0x28DE:008
Parameter
PDSS: Maximum speed Data type
U16 Default setting
0 rpm Attributes
- -
0x28DE:009
Parameter
PDSS: Maximum deceleration lower limit Data type
U16 Default setting
0 Attributes
- -
0x28DE:010
Parameter
PDSS: Maximum deceleration upper limit Data type
U16 Default setting
0 Attributes
- -
0x28DE:011
Parameter
PDSS: Error response Data type
U8 Default setting
STO [0] Attributes
- -
0x28DE:012
Parameter
PDSS: Currently monitored speed Data type
U16 Default setting
x rpm (Read only) Attributes
- -
0x28DE:013
Parameter
PDSS: Minimum difference monitored speed Data type
I16 Default setting
x rpm (Read only) Attributes
- -
0x28DF
Parameter
PDSS "PDSSpos observed" - Output Data type
U8 Default setting
Disabled [0] Attributes
- -
0x28E0
Parameter
PDSS "PDSSneg observed" - Output Data type
U8 Default setting
Disabled [0] Attributes
- -
0x28E4
Parameter
SBC Source SD-In Data type
U8 Default setting
Disabled [0] Attributes
-
No results.