i950
- Rated power 0.37 kW/0.5 HP
- Output current 2.4 A
- Output frequency 0-599 Hz
- Rated mains voltage 1/N(3)/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 0.55 kW/0.75 HP
- Output current 3.2 A
- Output frequency 0-599 Hz
- Rated mains voltage 1/N(3)/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 0.55 kW/0.75 HP
- Output current 1.8/1.6 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 0.75 kW/1 HP
- Output current 4.2 A
- Output frequency 0-599 Hz
- Rated mains voltage 1/N(3)/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 0.75 kW/1 HP
- Output current 2.4/2.1 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 1.5 kW/2 HP
- Output current 7 A
- Output frequency 0-599 Hz
- Rated mains voltage 1/N(3)/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 2.2 kW/3 HP
- Output current 9.6 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 2.2 kW/3 HP
- Output current 5.6/4.8 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 4 kW/5 HP
- Output current 16.5 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 4 kW/5 HP
- Output current 9.5/8.2 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 5.5 kW/7.5 HP
- Output current 23 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 7.5 kW/10 HP
- Output current 16.5/14 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 11 kW/15 HP
- Output current 23.5/21 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 15 kW/20 HP
- Output current 32/27 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 22 kW/30 HP
- Output current 47/40.4 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 30 kW/40 HP
- Output current 61/52 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 45 kW/60 HP
- Output current 89/77 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 55 kW/75 HP
- Output current 110/96 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 75 kW/100 HP
- Output current 150/124 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 90 kW/125 HP
- Output current 180/156 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 110 kW/150 HP
- Output current 212/180 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
-
Fault message ID
805312572 0x3000183C Description
CauseConfiguration error - Odd device at bus end
RemedyA surplus device was detected at the end of the bus.
Severity/responseAnalyze detailed error message in the logbook. Check network topology.
Warning
-
Fault message ID
805312578 0x30001842 Description
CauseInternal error counter resetted
RemedyInternal error counter resetted
Severity/responseFor information only. No remedy necessary.
Warning
-
Fault message ID
805312580 0x30001844 Description
CauseAll slaves 'Operational' again
RemedyAll slaves 'Operational' again
Severity/responseFor information only. No remedy necessary.
Warning
-
Fault message ID
805312581 0x30001845 Description
CauseCyclic command WKC error
RemedyWKC error
Severity/responseAnalyze detailed error message in the logbook. Check slave status. Check network topology.
Warning
-
Fault message ID
805312582 0x30001846 Description
CauseFrame response error
RemedyFrame response error
Severity/responseAnalyze detailed error message in the logbook. Check slave status. Check network topology.
Warning
-
Fault message ID
805312583 0x30001847 Description
CauseNot all slaves are 'Operational'
RemedyNot all slaves have been set to 'Operational'.
Severity/responseAnalyze detailed error message in the logbook. Check slave status. Check network topology.
Warning
-
Fault message ID
805312584 0x30001848 Description
CauseEmergency message - Overflow, further messages blocked
RemedyToo many emergency messages.
Severity/responseCheck if slave sends too many emergency messages. Eliminate cause.
Warning
-
Fault message ID
805312588 0x3000184C Description
CauseNew configuration loaded
RemedyNew configuration loaded
Severity/responseFor information only. No remedy necessary.
Warning
-
Fault message ID
805312589 0x3000184D Description
CauseNew configuration loaded, no slaves defined
RemedyNew configuration loaded, no slaves defined
Severity/responseFor information only. No remedy necessary.
Warning
-
Fault message ID
805312590 0x3000184E Description
CauseMaster - Start failed, configuration error
RemedyInternal error
Severity/responseSee related entries in the logbook.
Warning
-
Fault message ID
805312591 0x3000184F Description
CauseNew configuration loaded from slaves EEPROM
RemedyNew configuration loaded from slaves EEPROM
Severity/responseFor information only. No remedy necessary.
Warning
-
Fault message ID
805312598 0x30001856 Description
CauseMaster - Start failed
RemedyInternal error
Severity/responseSee related entries in the logbook.
Warning
-
Fault message ID
805312599 0x30001857 Description
CauseMaster - Start failed, bus configuration error
RemedyBus configuration error
Severity/responseCheck network topology.
Warning
-
Fault message ID
805312600 0x30001858 Description
CauseMaster - Start failed, EtherCAT cable disconnected
RemedyNetwork cabling is faulty.
Severity/responseCheck network cabling.
Warning
-
Fault message ID
805312601 0x30001859 Description
CauseMaster - Start failed, DC/DCM configuration
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
Fault message ID
805312602 0x3000185A Description
CauseMaster - Start failed, cannot set slaves to 'Pre-Operational'
RemedySlaves cannot be set to 'Pre-Operational'.
Severity/responseSee related entries in the logbook.
Warning
-
Fault message ID
805312608 0x30001860 Description
CauseMaster - Set 'Operational' failed
RemedyOperational' could not be set.
Severity/responseSee related entries in the logbook.
Warning
-
Fault message ID
805312609 0x30001861 Description
CauseMaster - Set 'Operational' failed, Master not initialized
RemedyMaster not initialized.
Severity/responseSee related entries in the logbook.
Warning
-
Fault message ID
805312610 0x30001862 Description
CauseMaster - Set 'Operational' failed, EtherCAT cable disconnected
RemedyNetwork cabling is faulty.
Severity/responseCheck network cabling.
Warning
-
Fault message ID
805312611 0x30001863 Description
CauseMaster - Set 'Operational' failed, DCM not in-sync
RemedyInternal error
Severity/responseSee related entries in the logbook.
Warning
-
Fault message ID
805312612 0x30001864 Description
CauseMaster - Set 'Operational' failed, bus cycle and DC different
RemedyIncorrect setting.
Severity/responseCheck bus cycle. Check sync period.
Warning
-
Fault message ID
805312613 0x30001865 Description
CauseMaster - Set 'Operational' takes some time...
RemedyMaster - Set 'Operational' takes some time...
Severity/responseFor information only. No remedy necessary.
Warning
-
Fault message ID
805312614 0x30001866 Description
RemedyMaster - Set 'Operational' failed, time-out
Severity/responseSee related entries in the logbook. Check slave status. Check network topology.
Warning
-
Fault message ID
805312615 0x30001867 Description
CauseMaster - Set 'Operational' failed, slave error
RemedySlave error
Severity/responseSee related entries in the logbook.
Warning
-
Fault message ID
805312616 0x30001868 Description
CauseMaster - Set 'Operational' aborted by reset command
RemedyMaster - Set 'Operational' aborted by reset command
Severity/responseFor information only. No remedy necessary.
Warning
-
0x2C07:012
Parameter
Inductance grid points (y) Lh saturation characteristic: y12 = L12 (x = 68.75 %) Data type
U16 Default setting
78 % Attributes
- -
0x2C07:013
Parameter
Inductance grid points (y) Lh saturation characteristic: y13 = L13 (x = 75.00 %) Data type
U16 Default setting
71 % Attributes
- -
0x2C07:014
Parameter
Inductance grid points (y) Lh saturation characteristic: y14 = L14 (x = 81.25 %) Data type
U16 Default setting
64 % Attributes
- -
0x2C07:015
Parameter
Inductance grid points (y) Lh saturation characteristic: y15 = L15 (x = 87.50 %) Data type
U16 Default setting
57 % Attributes
- -
0x2C07:016
Parameter
Inductance grid points (y) Lh saturation characteristic: y16 = L16 (x = 93.75 %) Data type
U16 Default setting
50 % Attributes
- -
0x2C07:017
Parameter
Inductance grid points (y) Lh saturation characteristic: y17 = L17 (x = 100.00 %) Data type
U16 Default setting
42 % Attributes
- -
0x2C08
Parameter
Method for setting motor parameters Data type
U8 Default setting
Select from catalogue (Lenze motors) [1] Attributes
- -
0x2C09:001
Parameter
q-axis Lss saturation characteristic: y1 = L01 (x = 0.00 %) Data type
U16 Default setting
165 % Attributes
- -
0x2C09:003
Parameter
q-axis Lss saturation characteristic: y3 = L03 (x = 12.50 %) Data type
U16 Default setting
146 % Attributes
- -
0x2C09:004
Parameter
q-axis Lss saturation characteristic: y4 = L04 (x = 18.75 %) Data type
U16 Default setting
117 % Attributes
- -
0x2C09:005
Parameter
q-axis Lss saturation characteristic: y5 = L05 (x = 25.00 %) Data type
U16 Default setting
97 % Attributes
- -
0x2C09:006
Parameter
q-axis Lss saturation characteristic: y6 = L06 (x = 31.25 %) Data type
U16 Default setting
82 % Attributes
- -
0x2C09:007
Parameter
q-axis Lss saturation characteristic: y7 = L07 (x = 37.50 %) Data type
U16 Default setting
71 % Attributes
- -
0x2C09:008
Parameter
q-axis Lss saturation characteristic: y8 = L08 (x = 42.75 %) Data type
U16 Default setting
62 % Attributes
- -
0x2C09:009
Parameter
q-axis Lss saturation characteristic: y9 = L09 (x = 50.00 %) Data type
U16 Default setting
55 % Attributes
- -
0x2C09:010
Parameter
q-axis Lss saturation characteristic: y10 = L10 (x = 56.25 %) Data type
U16 Default setting
50 % Attributes
- -
0x2C09:011
Parameter
q-axis Lss saturation characteristic: y11 = L11 (x = 62.50 %) Data type
U16 Default setting
46 % Attributes
- -
0x2C09:012
Parameter
q-axis Lss saturation characteristic: y12 = L12 (x = 68.75 %) Data type
U16 Default setting
43 % Attributes
- -
0x2C09:013
Parameter
q-axis Lss saturation characteristic: y13 = L13 (x = 75.00 %) Data type
U16 Default setting
42 % Attributes
- -
0x2C09:014
Parameter
q-axis Lss saturation characteristic: y14 = L14 (x = 81.25 %) Data type
U16 Default setting
41 % Attributes
- -
0x2C09:015
Parameter
q-axis Lss saturation characteristic: y15 = L15 (x = 87.50 %) Data type
U16 Default setting
41 % Attributes
- -
0x2C09:016
Parameter
q-axis Lss saturation characteristic: y16 = L16 (x = 93.25 %) Data type
U16 Default setting
41 % Attributes
- -
0x2C09:017
Parameter
q-axis Lss saturation characteristic: y17 = L17 (x = 100.00 %) Data type
U16 Default setting
41 % Attributes
- -
0x2C09:018
Parameter
q-axis Lss saturation characteristic: Table source Data type
U16 Default setting
Identical to d-axis (0x2C04) [0] Attributes
- -
0x2C16:001
Parameter
Cogging torque compensation: Enable compensation Data type
U8 Default setting
On [1] Attributes
-