i950
- Rated power 0.37 kW/0.5 HP
- Output current 2.4 A
- Output frequency 0-599 Hz
- Rated mains voltage 1/N(3)/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 0.55 kW/0.75 HP
- Output current 3.2 A
- Output frequency 0-599 Hz
- Rated mains voltage 1/N(3)/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 0.55 kW/0.75 HP
- Output current 1.8/1.6 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 0.75 kW/1 HP
- Output current 4.2 A
- Output frequency 0-599 Hz
- Rated mains voltage 1/N(3)/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 0.75 kW/1 HP
- Output current 2.4/2.1 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 1.5 kW/2 HP
- Output current 7 A
- Output frequency 0-599 Hz
- Rated mains voltage 1/N(3)/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 2.2 kW/3 HP
- Output current 9.6 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 2.2 kW/3 HP
- Output current 5.6/4.8 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 4 kW/5 HP
- Output current 16.5 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 4 kW/5 HP
- Output current 9.5/8.2 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 5.5 kW/7.5 HP
- Output current 23 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 7.5 kW/10 HP
- Output current 16.5/14 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 11 kW/15 HP
- Output current 23.5/21 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 15 kW/20 HP
- Output current 32/27 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 22 kW/30 HP
- Output current 47/40.4 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 30 kW/40 HP
- Output current 61/52 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 45 kW/60 HP
- Output current 89/77 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 55 kW/75 HP
- Output current 110/96 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 75 kW/100 HP
- Output current 150/124 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 90 kW/125 HP
- Output current 180/156 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 110 kW/150 HP
- Output current 212/180 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
-
Fault message ID
805312572 0x3000183C Description
CauseConfiguration error - Odd device at bus end
RemedyA surplus device was detected at the end of the bus.
Severity/responseAnalyze detailed error message in the logbook. Check network topology.
Warning
-
Fault message ID
805312578 0x30001842 Description
CauseInternal error counter resetted
RemedyInternal error counter resetted
Severity/responseFor information only. No remedy necessary.
Warning
-
Fault message ID
805312580 0x30001844 Description
CauseAll slaves 'Operational' again
RemedyAll slaves 'Operational' again
Severity/responseFor information only. No remedy necessary.
Warning
-
Fault message ID
805312581 0x30001845 Description
CauseCyclic command WKC error
RemedyWKC error
Severity/responseAnalyze detailed error message in the logbook. Check slave status. Check network topology.
Warning
-
Fault message ID
805312582 0x30001846 Description
CauseFrame response error
RemedyFrame response error
Severity/responseAnalyze detailed error message in the logbook. Check slave status. Check network topology.
Warning
-
Fault message ID
805312583 0x30001847 Description
CauseNot all slaves are 'Operational'
RemedyNot all slaves have been set to 'Operational'.
Severity/responseAnalyze detailed error message in the logbook. Check slave status. Check network topology.
Warning
-
Fault message ID
805312584 0x30001848 Description
CauseEmergency message - Overflow, further messages blocked
RemedyToo many emergency messages.
Severity/responseCheck if slave sends too many emergency messages. Eliminate cause.
Warning
-
Fault message ID
805312588 0x3000184C Description
CauseNew configuration loaded
RemedyNew configuration loaded
Severity/responseFor information only. No remedy necessary.
Warning
-
Fault message ID
805312589 0x3000184D Description
CauseNew configuration loaded, no slaves defined
RemedyNew configuration loaded, no slaves defined
Severity/responseFor information only. No remedy necessary.
Warning
-
Fault message ID
805312590 0x3000184E Description
CauseMaster - Start failed, configuration error
RemedyInternal error
Severity/responseSee related entries in the logbook.
Warning
-
Fault message ID
805312591 0x3000184F Description
CauseNew configuration loaded from slaves EEPROM
RemedyNew configuration loaded from slaves EEPROM
Severity/responseFor information only. No remedy necessary.
Warning
-
Fault message ID
805312598 0x30001856 Description
CauseMaster - Start failed
RemedyInternal error
Severity/responseSee related entries in the logbook.
Warning
-
Fault message ID
805312599 0x30001857 Description
CauseMaster - Start failed, bus configuration error
RemedyBus configuration error
Severity/responseCheck network topology.
Warning
-
Fault message ID
805312600 0x30001858 Description
CauseMaster - Start failed, EtherCAT cable disconnected
RemedyNetwork cabling is faulty.
Severity/responseCheck network cabling.
Warning
-
Fault message ID
805312601 0x30001859 Description
CauseMaster - Start failed, DC/DCM configuration
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
Fault message ID
805312602 0x3000185A Description
CauseMaster - Start failed, cannot set slaves to 'Pre-Operational'
RemedySlaves cannot be set to 'Pre-Operational'.
Severity/responseSee related entries in the logbook.
Warning
-
Fault message ID
805312608 0x30001860 Description
CauseMaster - Set 'Operational' failed
RemedyOperational' could not be set.
Severity/responseSee related entries in the logbook.
Warning
-
Fault message ID
805312609 0x30001861 Description
CauseMaster - Set 'Operational' failed, Master not initialized
RemedyMaster not initialized.
Severity/responseSee related entries in the logbook.
Warning
-
Fault message ID
805312610 0x30001862 Description
CauseMaster - Set 'Operational' failed, EtherCAT cable disconnected
RemedyNetwork cabling is faulty.
Severity/responseCheck network cabling.
Warning
-
Fault message ID
805312611 0x30001863 Description
CauseMaster - Set 'Operational' failed, DCM not in-sync
RemedyInternal error
Severity/responseSee related entries in the logbook.
Warning
-
Fault message ID
805312612 0x30001864 Description
CauseMaster - Set 'Operational' failed, bus cycle and DC different
RemedyIncorrect setting.
Severity/responseCheck bus cycle. Check sync period.
Warning
-
Fault message ID
805312613 0x30001865 Description
CauseMaster - Set 'Operational' takes some time...
RemedyMaster - Set 'Operational' takes some time...
Severity/responseFor information only. No remedy necessary.
Warning
-
Fault message ID
805312614 0x30001866 Description
RemedyMaster - Set 'Operational' failed, time-out
Severity/responseSee related entries in the logbook. Check slave status. Check network topology.
Warning
-
Fault message ID
805312615 0x30001867 Description
CauseMaster - Set 'Operational' failed, slave error
RemedySlave error
Severity/responseSee related entries in the logbook.
Warning
-
Fault message ID
805312616 0x30001868 Description
CauseMaster - Set 'Operational' aborted by reset command
RemedyMaster - Set 'Operational' aborted by reset command
Severity/responseFor information only. No remedy necessary.
Warning
-
0x2360
Parameter
EtherCAT communication Data type
U8 Default setting
No action/no error [0] Attributes
- -
0x2362:007
Parameter
Active EtherCAT settings: Tx length Data type
U16 Default setting
- (Read only) Attributes
- -
0x2362:008
Parameter
Active EtherCAT settings: Rx length Data type
U16 Default setting
- (Read only) Attributes
- -
0x2368
Parameter
EtherCAT status Data type
U16 Default setting
- (Read only) Attributes
- -
0x2369
Parameter
EtherCAT error Data type
U16 Default setting
- (Read only) Attributes
H -
0x2371:009
Parameter
onboard EtherCAT: Interface mode Data type
U8 Default setting
Slave [0] Attributes
C -
0x2372:009
Parameter
onboard EtherCAT - Information: Active interface mode Data type
U8 Default setting
- (Read only) Attributes
- -
0x2378
Parameter
onboard EtherCAT - status Data type
U16 Default setting
- (Read only) Attributes
- -
0x2379
Parameter
onboard EtherCAT - Error Data type
U16 Default setting
- (Read only) Attributes
- -
0x2380
Parameter
PROFINET communication Data type
U8 Default setting
No action/no error [0] Attributes
- -
0x2381:001
Parameter
PROFINET settings: IP address Data type
U32 Default setting
0.0.0.0 Attributes
E -
0x2381:002
Parameter
PROFINET settings: Subnet Data type
U32 Default setting
0.0.0.0 Attributes
E -
0x2381:003
Parameter
PROFINET settings: Gateway Data type
U32 Default setting
0.0.0.0 Attributes
E -
0x2381:004
Parameter
PROFINET settings: Station name Data type
STRING[240] Attributes
- -
0x2381:005
Parameter
PROFINET settings: I&M1 System designation Data type
STRING[32] Attributes
- -
0x2381:006
Parameter
PROFINET settings: I&M1 Installation site Data type
STRING[22] Attributes
- -
0x2381:007
Parameter
PROFINET settings: I&M2 Installation date Data type
STRING[16] Attributes
- -
0x2381:008
Parameter
PROFINET settings: I&M3 additional information Data type
STRING[54] Attributes
- -
0x2381:009
Parameter
PROFINET settings: I&M4 signature code Data type
OCTET[54] Default setting
"00000000000000000000000000000000 000000000000000000000000000000000 000000000000000000000000000000000 0000000000" Attributes
- -
0x2382:001
Parameter
Active PROFINET settings: IP address Data type
U32 Default setting
- (Read only) Attributes
E -
0x2382:002
Parameter
Active PROFINET settings: Subnet Data type
U32 Default setting
- (Read only) Attributes
E -
0x2382:003
Parameter
Active PROFINET settings: Gateway Data type
U32 Default setting
- (Read only) Attributes
E -
0x2382:004
Parameter
Active PROFINET settings: Station name Data type
STRING[240] Default setting
- (Read only) Attributes
- -
0x2382:005
Parameter
Active PROFINET settings: MAC Address Data type
OCTET[6] Default setting
- (Read only) Attributes
- -
0x2388
Parameter
PROFINET status Data type
U16 Default setting
- (Read only) Attributes
H