i950

i950-C0.37/230-2 i950-C0.37/230-2 Description
Lenze logo Order code / SKU
On request
  • Rated power 0.37 kW/0.5 HP
  • Output current 2.4 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 1/N(3)/PE 230/240 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter not integrated
i950-C0.55/230-2 i950-C0.55/230-2 Description
Lenze logo Order code / SKU
On request
  • Rated power 0.55 kW/0.75 HP
  • Output current 3.2 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 1/N(3)/PE 230/240 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter not integrated
i950-C0.55/400-3 i950-C0.55/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 0.55 kW/0.75 HP
  • Output current 1.8/1.6 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter Integrated
i950-C0.75/230-2 i950-C0.75/230-2 Description
Lenze logo Order code / SKU
On request
  • Rated power 0.75 kW/1 HP
  • Output current 4.2 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 1/N(3)/PE 230/240 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter not integrated
i950-C0.75/400-3 i950-C0.75/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 0.75 kW/1 HP
  • Output current 2.4/2.1 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter Integrated
i950-C1.5/230-2 i950-C1.5/230-2 Description
Lenze logo Order code / SKU
On request
  • Rated power 1.5 kW/2 HP
  • Output current 7 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 1/N(3)/PE 230/240 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter not integrated
i950-C2.2/230-3 i950-C2.2/230-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 2.2 kW/3 HP
  • Output current 9.6 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 230/240 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter not integrated
i950-C2.2/400-3 i950-C2.2/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 2.2 kW/3 HP
  • Output current 5.6/4.8 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter Integrated
i950-C4/230-3 i950-C4/230-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 4 kW/5 HP
  • Output current 16.5 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 230/240 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter not integrated
i950-C4/400-3 i950-C4/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 4 kW/5 HP
  • Output current 9.5/8.2 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter Integrated
i950-C5.5/230-3 i950-C5.5/230-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 5.5 kW/7.5 HP
  • Output current 23 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 230/240 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter not integrated
i950-C7.5/400-3 i950-C7.5/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 7.5 kW/10 HP
  • Output current 16.5/14 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter Integrated
i950-C11/400-3 i950-C11/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 11 kW/15 HP
  • Output current 23.5/21 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter Integrated
i950-C15/400-3 i950-C15/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 15 kW/20 HP
  • Output current 32/27 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter Integrated
i950-C22/400-3 i950-C22/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 22 kW/30 HP
  • Output current 47/40.4 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter Integrated
i950-C30/400-3 i950-C30/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 30 kW/40 HP
  • Output current 61/52 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter Integrated
i950-C45/400-3 i950-C45/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 45 kW/60 HP
  • Output current 89/77 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter Integrated
i950-C55/400-3 i950-C55/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 55 kW/75 HP
  • Output current 110/96 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter Integrated
i950-C75/400-3 i950-C75/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 75 kW/100 HP
  • Output current 150/124 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter Integrated
i950-C90/400-3 i950-C90/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 90 kW/125 HP
  • Output current 180/156 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter Integrated
i950-C110/400-3 i950-C110/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 110 kW/150 HP
  • Output current 212/180 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter Integrated
Showing 401–425 of 563
  • Fault message ID
    805311966
    0x300015DE Description

    MbxTferRcv - Write IDN failure

    Cause

    IDN - Write error.

    Remedy

    Analyze detailed error message in the logbook.

    Severity/response

    Warning

  • Fault message ID
    805311967
    0x300015DF Description

    MbxTferRcv - Read IDN failure

    Cause

    IDN - read error.

    Remedy

    Analyze detailed error message in the logbook.

    Severity/response

    Warning

  • Fault message ID
    805311968
    0x300015E0 Description

    SoE - Emergency transfer failure

    Cause

    SoE - emergency transfer error.

    Remedy

    Analyze detailed error message in the logbook.

    Severity/response

    Warning

  • Fault message ID
    805311969
    0x300015E1 Description

    SoE - Emergency request

    Cause

    SoE - emergency request.

    Remedy

    Analyze detailed error message in the logbook.

    Severity/response

    Warning

  • Fault message ID
    805311970
    0x300015E2 Description

    SoE - Notification transfer failure

    Cause

    SoE - transfer error during a notification.

    Remedy

    Analyze detailed error message in the logbook.

    Severity/response

    Warning

  • Fault message ID
    805311971
    0x300015E3 Description

    SoE - Notification request

    Cause

    SoE - notification has been requested.

    Remedy

    Analyze detailed error message in the logbook.

    Severity/response

    Warning

  • Fault message ID
    805311972
    0x300015E4 Description

    FoE abort

    Cause

    FoE has been aborted.

    Remedy

    Check file. Check transfer properties. Analyze detailed error message in the logbook.

    Severity/response

    Warning

  • Fault message ID
    805312069
    0x30001645 Description

    Bus scan state

    Cause

    Bus scan state

    Remedy

    For information only. No remedy necessary.

    Severity/response

    Warning

  • Fault message ID
    805312071
    0x30001647 Description

    Latch/Edge - No edge

    Cause

    No edge.

    Remedy

    Analyze detailed error message in the logbook.

    Severity/response

    Warning

  • Fault message ID
    805312072
    0x30001648 Description

    Remote API diagnosis port - Connection established

    Cause

    Remote API diagnosis port - Connection established

    Remedy

    For information only. No remedy necessary.

    Severity/response

    Warning

  • Fault message ID
    805312073
    0x30001649 Description

    Remote API diagnosis port - Connection disconnected

    Cause

    Remote API diagnosis port - Connection disconnected

    Remedy

    For information only. No remedy necessary.

    Severity/response

    Warning

  • Fault message ID
    805312074
    0x3000164A Description

    Client registered from cookie

    Cause

    Client has registered with cookie.

    Remedy

    Analyze detailed error message in the logbook.

    Severity/response

    Warning

  • Fault message ID
    805312075
    0x3000164B Description

    Client unregistered from cookie

    Cause

    Client logged out from cookie.

    Remedy

    Analyze detailed error message in the logbook.

    Severity/response

    Warning

  • Fault message ID
    805312076
    0x3000164C Description

    Unknown notification

    Cause

    Internal error

    Remedy

    Restart the device. If the error persists, contact the manufacturer.

    Severity/response

    Warning

  • Fault message ID
    805312077
    0x3000164D Description

    Slave latched

    Cause

    Internal error

    Remedy

    Restart the device. If the error persists, contact the manufacturer.

    Severity/response

    Warning

  • Fault message ID
    805312078
    0x3000164E Description

    Bus scan - Error

    Cause

    Internal error

    Remedy

    Restart the device. If the error persists, contact the manufacturer.

    Severity/response

    Warning

  • Fault message ID
    805312079
    0x3000164F Description

    Invalid number of slaves

    Cause

    The number of detected slaves differs from the number of expected slaves.

    Remedy

    Analyze detailed error message in the logbook. Check network topology.

    Severity/response

    Warning

  • Fault message ID
    805312080
    0x30001650 Description

    Cannot get SlaveInfo

    Cause

    Internal error

    Remedy

    Restart the device. If the error persists, contact the manufacturer.

    Severity/response

    Warning

  • Fault message ID
    805312081
    0x30001651 Description

    Deviation of slave

    Cause

    Internal error

    Remedy

    Restart the device. If the error persists, contact the manufacturer.

    Severity/response

    Warning

  • Fault message ID
    805312082
    0x30001652 Description

    Slave is not configured

    Cause

    The slave is not configured

    Remedy

    Check slave status. Check network topology.

    Severity/response

    Warning

  • Fault message ID
    805312083
    0x30001653 Description

    SlaveInfo

    Cause

    Internal error

    Remedy

    Restart the device. If the error persists, contact the manufacturer.

    Severity/response

    Warning

  • Fault message ID
    805312084
    0x30001654 Description

    SLV - Error retrieving configuration data

    Cause

    Internal error

    Remedy

    Restart the device. If the error persists, contact the manufacturer.

    Severity/response

    Warning

  • Fault message ID
    805312085
    0x30001655 Description

    Bus scan - Deviation

    Cause

    Internal error

    Remedy

    Restart the device. If the error persists, contact the manufacturer.

    Severity/response

    Warning

  • Fault message ID
    805312086
    0x30001656 Description

    Communication to device interrupted

    Cause

    Communication interruption

    Remedy

    Check slave status. Check network topology.

    Severity/response

    Warning

  • Fault message ID
    805312087
    0x30001657 Description

    Slave is not in expected status

    Cause

    Detected slave status differs from expected slave status.

    Remedy

    Analyze detailed error message in the logbook. Check slave status. Check network topology.

    Severity/response

    Warning

← Previous Page 17 of 23 Next →