i950
- Rated power 0.37 kW/0.5 HP
- Output current 2.4 A
- Output frequency 0-599 Hz
- Rated mains voltage 1/N(3)/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 0.55 kW/0.75 HP
- Output current 3.2 A
- Output frequency 0-599 Hz
- Rated mains voltage 1/N(3)/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 0.55 kW/0.75 HP
- Output current 1.8/1.6 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 0.75 kW/1 HP
- Output current 4.2 A
- Output frequency 0-599 Hz
- Rated mains voltage 1/N(3)/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 0.75 kW/1 HP
- Output current 2.4/2.1 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 1.5 kW/2 HP
- Output current 7 A
- Output frequency 0-599 Hz
- Rated mains voltage 1/N(3)/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 2.2 kW/3 HP
- Output current 9.6 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 2.2 kW/3 HP
- Output current 5.6/4.8 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 4 kW/5 HP
- Output current 16.5 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 4 kW/5 HP
- Output current 9.5/8.2 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 5.5 kW/7.5 HP
- Output current 23 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 7.5 kW/10 HP
- Output current 16.5/14 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 11 kW/15 HP
- Output current 23.5/21 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 15 kW/20 HP
- Output current 32/27 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 22 kW/30 HP
- Output current 47/40.4 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 30 kW/40 HP
- Output current 61/52 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 45 kW/60 HP
- Output current 89/77 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 55 kW/75 HP
- Output current 110/96 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 75 kW/100 HP
- Output current 150/124 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 90 kW/125 HP
- Output current 180/156 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 110 kW/150 HP
- Output current 212/180 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
-
Fault message ID
805311966 0x300015DE Description
CauseMbxTferRcv - Write IDN failure
RemedyIDN - Write error.
Severity/responseAnalyze detailed error message in the logbook.
Warning
-
Fault message ID
805311967 0x300015DF Description
CauseMbxTferRcv - Read IDN failure
RemedyIDN - read error.
Severity/responseAnalyze detailed error message in the logbook.
Warning
-
Fault message ID
805311968 0x300015E0 Description
CauseSoE - Emergency transfer failure
RemedySoE - emergency transfer error.
Severity/responseAnalyze detailed error message in the logbook.
Warning
-
Fault message ID
805311969 0x300015E1 Description
CauseSoE - Emergency request
RemedySoE - emergency request.
Severity/responseAnalyze detailed error message in the logbook.
Warning
-
Fault message ID
805311970 0x300015E2 Description
CauseSoE - Notification transfer failure
RemedySoE - transfer error during a notification.
Severity/responseAnalyze detailed error message in the logbook.
Warning
-
Fault message ID
805311971 0x300015E3 Description
CauseSoE - Notification request
RemedySoE - notification has been requested.
Severity/responseAnalyze detailed error message in the logbook.
Warning
-
Fault message ID
805311972 0x300015E4 Description
CauseFoE abort
RemedyFoE has been aborted.
Severity/responseCheck file. Check transfer properties. Analyze detailed error message in the logbook.
Warning
-
Fault message ID
805312069 0x30001645 Description
CauseBus scan state
RemedyBus scan state
Severity/responseFor information only. No remedy necessary.
Warning
-
Fault message ID
805312071 0x30001647 Description
CauseLatch/Edge - No edge
RemedyNo edge.
Severity/responseAnalyze detailed error message in the logbook.
Warning
-
Fault message ID
805312072 0x30001648 Description
CauseRemote API diagnosis port - Connection established
RemedyRemote API diagnosis port - Connection established
Severity/responseFor information only. No remedy necessary.
Warning
-
Fault message ID
805312073 0x30001649 Description
CauseRemote API diagnosis port - Connection disconnected
RemedyRemote API diagnosis port - Connection disconnected
Severity/responseFor information only. No remedy necessary.
Warning
-
Fault message ID
805312074 0x3000164A Description
CauseClient registered from cookie
RemedyClient has registered with cookie.
Severity/responseAnalyze detailed error message in the logbook.
Warning
-
Fault message ID
805312075 0x3000164B Description
CauseClient unregistered from cookie
RemedyClient logged out from cookie.
Severity/responseAnalyze detailed error message in the logbook.
Warning
-
Fault message ID
805312076 0x3000164C Description
CauseUnknown notification
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
Fault message ID
805312077 0x3000164D Description
CauseSlave latched
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
Fault message ID
805312078 0x3000164E Description
CauseBus scan - Error
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
Fault message ID
805312079 0x3000164F Description
CauseInvalid number of slaves
RemedyThe number of detected slaves differs from the number of expected slaves.
Severity/responseAnalyze detailed error message in the logbook. Check network topology.
Warning
-
Fault message ID
805312080 0x30001650 Description
CauseCannot get SlaveInfo
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
Fault message ID
805312081 0x30001651 Description
CauseDeviation of slave
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
Fault message ID
805312082 0x30001652 Description
CauseSlave is not configured
RemedyThe slave is not configured
Severity/responseCheck slave status. Check network topology.
Warning
-
Fault message ID
805312083 0x30001653 Description
CauseSlaveInfo
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
Fault message ID
805312084 0x30001654 Description
CauseSLV - Error retrieving configuration data
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
Fault message ID
805312085 0x30001655 Description
CauseBus scan - Deviation
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
Fault message ID
805312086 0x30001656 Description
CauseCommunication to device interrupted
RemedyCommunication interruption
Severity/responseCheck slave status. Check network topology.
Warning
-
Fault message ID
805312087 0x30001657 Description
CauseSlave is not in expected status
RemedyDetected slave status differs from expected slave status.
Severity/responseAnalyze detailed error message in the logbook. Check slave status. Check network topology.
Warning
-
0xA680:010
Parameter
Systembus input data: Systembus data input 10 Data type
U32 Default setting
0 Attributes
- -
0xA680:011
Parameter
Systembus input data: Systembus data input 11 Data type
U32 Default setting
0 Attributes
- -
0xA680:012
Parameter
Systembus input data: Systembus data input 12 Data type
U32 Default setting
0 Attributes
- -
0xA680:013
Parameter
Systembus input data: Systembus data input 13 Data type
U32 Default setting
0 Attributes
- -
0xA680:014
Parameter
Systembus input data: Systembus data input 14 Data type
U32 Default setting
0 Attributes
- -
0xA680:015
Parameter
Systembus input data: Systembus data input 15 Data type
U32 Default setting
0 Attributes
- -
0xA680:016
Parameter
Systembus input data: Systembus data input 16 Data type
U32 Default setting
0 Attributes
- -
0xE600:001
Parameter
FSoE Slave Frame Elements: Command Data type
U8 Default setting
- (Read only) Attributes
- -
0xE600:002
Parameter
FSoE Slave Frame Elements: Connection ID Data type
U16 Default setting
- (Read only) Attributes
- -
0xE600:003
Parameter
FSoE Slave Frame Elements: CRC_0 Data type
U16 Default setting
- (Read only) Attributes
- -
0xE600:004
Parameter
FSoE Slave Frame Elements: CRC_1 Data type
U16 Default setting
- (Read only) Attributes
- -
0xE600:005
Parameter
FSoE Slave Frame Elements: CRC_2 Data type
U16 Default setting
- (Read only) Attributes
- -
0xE600:006
Parameter
FSoE Slave Frame Elements: CRC_3 Data type
U16 Default setting
- (Read only) Attributes
- -
0xE600:007
Parameter
FSoE Slave Frame Elements: CRC_4 Data type
U16 Default setting
- (Read only) Attributes
- -
0xE600:008
Parameter
FSoE Slave Frame Elements: CRC_5 Data type
U16 Default setting
- (Read only) Attributes
- -
0xE600:009
Parameter
FSoE Slave Frame Elements: CRC_6 Data type
U16 Default setting
- (Read only) Attributes
- -
0xE700:001
Parameter
FSoE Master Frame Elements: Command Data type
U8 Default setting
- (Read only) Attributes
- -
0xE700:002
Parameter
FSoE Master Frame Elements: Connection ID Data type
U16 Default setting
- (Read only) Attributes
- -
0xE700:003
Parameter
FSoE Master Frame Elements: CRC_0 Data type
U16 Default setting
- (Read only) Attributes
- -
0xE700:004
Parameter
FSoE Master Frame Elements: CRC_1 Data type
U16 Default setting
- (Read only) Attributes
- -
0xE901:001
Parameter
FSoE Connection Communication Parameter: Version Data type
STRING[2] Default setting
- (Read only) Attributes
- -
0xE901:002
Parameter
FSoE Connection Communication Parameter: Safety address Data type
U16 Default setting
- (Read only) Attributes
- -
0xE901:003
Parameter
FSoE Connection Communication Parameter: Connection ID Data type
U16 Default setting
- (Read only) Attributes
- -
0xE901:004
Parameter
FSoE Connection Communication Parameter: Watchdog Time Data type
U16 Default setting
- (Read only) Attributes
- -
0xE901:006
Parameter
FSoE Connection Communication Parameter: Connection Type Data type
U16 Default setting
- (Read only) Attributes
-
No results.