i950
- Rated power 0.37 kW/0.5 HP
- Output current 2.4 A
- Output frequency 0-599 Hz
- Rated mains voltage 1/N(3)/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 0.55 kW/0.75 HP
- Output current 3.2 A
- Output frequency 0-599 Hz
- Rated mains voltage 1/N(3)/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 0.55 kW/0.75 HP
- Output current 1.8/1.6 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 0.75 kW/1 HP
- Output current 4.2 A
- Output frequency 0-599 Hz
- Rated mains voltage 1/N(3)/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 0.75 kW/1 HP
- Output current 2.4/2.1 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 1.5 kW/2 HP
- Output current 7 A
- Output frequency 0-599 Hz
- Rated mains voltage 1/N(3)/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 2.2 kW/3 HP
- Output current 9.6 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 2.2 kW/3 HP
- Output current 5.6/4.8 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 4 kW/5 HP
- Output current 16.5 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 4 kW/5 HP
- Output current 9.5/8.2 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 5.5 kW/7.5 HP
- Output current 23 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 7.5 kW/10 HP
- Output current 16.5/14 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 11 kW/15 HP
- Output current 23.5/21 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 15 kW/20 HP
- Output current 32/27 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 22 kW/30 HP
- Output current 47/40.4 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 30 kW/40 HP
- Output current 61/52 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 45 kW/60 HP
- Output current 89/77 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 55 kW/75 HP
- Output current 110/96 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 75 kW/100 HP
- Output current 150/124 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 90 kW/125 HP
- Output current 180/156 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 110 kW/150 HP
- Output current 212/180 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
-
Fault message ID
805311754 0x3000150A Description
Severity/responseRAP - Watchdog expired
Warning
-
Fault message ID
805311755 0x3000150B Description
Severity/responseRAP - Connecting 2nd server denied, multi server support is disabled
Warning
-
Fault message ID
805311756 0x3000150C Description
Severity/responseRAP - Logon aborted
Warning
-
Fault message ID
805311757 0x3000150D Description
Severity/responseRAP - Invalid version
Warning
-
Fault message ID
805311769 0x30001519 Description
Severity/responseRAP - Server stopped
Warning
-
Fault message ID
805311770 0x3000151A Description
Severity/responseRAP - Watchdog expired
Warning
-
Fault message ID
805311771 0x3000151B Description
Severity/responseRAP - Reconnect time expired
Warning
-
Fault message ID
805311772 0x3000151C Description
Severity/responseRAP - Client logged on
Warning
-
Fault message ID
805311773 0x3000151D Description
Severity/responseRAP - Client reconnected
Warning
-
Fault message ID
805311774 0x3000151E Description
Severity/responseRAP - Socket changed after reconnect
Warning
-
Fault message ID
805311817 0x30001549 Description
Severity/responseDCM - Init function not called or call not successful
Warning
-
Fault message ID
805311818 0x3000154A Description
Severity/responseDCM - Controller error - synchronization out of limit
Warning
-
Fault message ID
805311819 0x3000154B Description
Severity/responseDCM - Not enough memory
Warning
-
Fault message ID
805311820 0x3000154C Description
Severity/responseDCM - Hardware layer - (BSP) invalid
Warning
-
Fault message ID
805311821 0x3000154D Description
Severity/responseDCM - Hardware layer - Error while modifying the timer
Warning
-
Fault message ID
805311822 0x3000154E Description
Severity/responseDCM - Hardware layer - Timer is not running
Warning
-
Fault message ID
805311823 0x3000154F Description
Severity/responseDCM - Hardware layer - Function is called on wrong CPU
Warning
-
Fault message ID
805311881 0x30001589 Description
CauseEtherCAT - State change of master successful
RemedyEtherCAT - State change of master successful
Severity/responseFor information only. No remedy necessary.
Warning
-
Fault message ID
805311882 0x3000158A Description
CauseEtherCAT - Bus scan successful
RemedyEtherCAT - Bus scan successful
Severity/responseFor information only. No remedy necessary.
Warning
-
Fault message ID
805311883 0x3000158B Description
CauseEtherCAT - Bus scan error
RemedyError in the network topology
Severity/responseCheck network topology.
Warning
-
Fault message ID
805311884 0x3000158C Description
Severity/responseEtherCAT - Distributed clocks state
Warning
-
Fault message ID
805311885 0x3000158D Description
Severity/responseEtherCAT - Distributed clocks - Latching state
Warning
-
Fault message ID
805311886 0x3000158E Description
CauseCoE - SDO download failure
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
Fault message ID
805311887 0x3000158F Description
CauseCoE - SDO upload failure
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
Fault message ID
805311888 0x30001590 Description
CauseCoE - OD-list upload failure
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
0x60B2
Parameter
Offset torque Data type
I16 Default setting
0.0 % Attributes
- -
0x60B8
Parameter
Touch probe settings Data type
U16 Default setting
0x0000 Attributes
H -
0x60B9
Parameter
Touch probe status Data type
U16 Default setting
- (Read only) Attributes
H -
0x60BA
Parameter
Touch probe 1: Position at pos. edge Data type
I32 Default setting
- (Read only) Attributes
- -
0x60BB
Parameter
Touch probe 1: Position at neg. edge Data type
I32 Default setting
- (Read only) Attributes
- -
0x60BC
Parameter
Touch probe 2: Position at pos. edge Data type
I32 Default setting
- (Read only) Attributes
- -
0x60BD
Parameter
Touch probe 2: Position at neg. edge Data type
I32 Default setting
- (Read only) Attributes
- -
0x60C0
Parameter
Interpolation mode Data type
I16 Default setting
Quadratic [-1] Attributes
- -
0x60C2:001
Parameter
Interpolation time: Interpolation time mantissa Data type
U8 Default setting
1 Attributes
- -
0x60C2:002
Parameter
Interpolation time: Interpolation time exponent Data type
I8 Default setting
-3 Attributes
- -
0x60E0
Parameter
Positive torque limit Data type
U16 Default setting
100.0 % Attributes
- -
0x60E1
Parameter
Negative torque limit Data type
U16 Default setting
100.0 % Attributes
- -
0x60E4:001
Parameter
Additional position actual value: Load encoder/ master encoder - actual position Data type
I32 Default setting
- (Read only) Attributes
- -
0x60E5:001
Parameter
Additional velocity actual value: Load encoder/ master encoder - actual speed Data type
I32 Default setting
rpm (Read only) Attributes
- -
0x60E6:001
Parameter
Additional position encoder resolution - encoder increments: Load encoder/master encoder - number of increments Data type
U32 Default setting
16 Bit [65536] Attributes
C -
0x60EB:001
Parameter
Additional position encoder resolution - motor revolutions: Load encoder/master encoder - resolution of motor revolutions Data type
U32 Default setting
1 Attributes
C -
0x60F4
Parameter
Following error actual value Data type
I32 Default setting
- (Read only) Attributes
- -
0x60FA
Parameter
Control effort Data type
I32 Default setting
rpm (Read only) Attributes
- -
0x60FC
Parameter
Position demand internal value Data type
I32 Default setting
- (Read only) Attributes
- -
0x60FD
Parameter
Digital input status Data type
U32 Default setting
- (Read only) Attributes
H -
0x60FE:001
Parameter
Digital outputs: Digital output status Data type
U32 Default setting
0x00000000 Attributes
H -
0x60FF
Parameter
Set speed Data type
I32 Default setting
0.00 rpm Attributes
- -
0x6404
Parameter
Motor manufacturer Data type
STRING[50] Default setting
"Lenze" Attributes
- -
0x6502
Parameter
Supported drive modes Data type
U32 Default setting
- (Read only) Attributes
H -
0x67FF
Parameter
Device profile number Data type
U32 Default setting
- (Read only) Attributes
-
No results.