i950
- Rated power 0.37 kW/0.5 HP
- Output current 2.4 A
- Output frequency 0-599 Hz
- Rated mains voltage 1/N(3)/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 0.55 kW/0.75 HP
- Output current 3.2 A
- Output frequency 0-599 Hz
- Rated mains voltage 1/N(3)/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 0.55 kW/0.75 HP
- Output current 1.8/1.6 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 0.75 kW/1 HP
- Output current 4.2 A
- Output frequency 0-599 Hz
- Rated mains voltage 1/N(3)/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 0.75 kW/1 HP
- Output current 2.4/2.1 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 1.5 kW/2 HP
- Output current 7 A
- Output frequency 0-599 Hz
- Rated mains voltage 1/N(3)/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 2.2 kW/3 HP
- Output current 9.6 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 2.2 kW/3 HP
- Output current 5.6/4.8 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 4 kW/5 HP
- Output current 16.5 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 4 kW/5 HP
- Output current 9.5/8.2 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 5.5 kW/7.5 HP
- Output current 23 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 7.5 kW/10 HP
- Output current 16.5/14 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 11 kW/15 HP
- Output current 23.5/21 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 15 kW/20 HP
- Output current 32/27 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 22 kW/30 HP
- Output current 47/40.4 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 30 kW/40 HP
- Output current 61/52 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 45 kW/60 HP
- Output current 89/77 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 55 kW/75 HP
- Output current 110/96 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 75 kW/100 HP
- Output current 150/124 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 90 kW/125 HP
- Output current 180/156 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 110 kW/150 HP
- Output current 212/180 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
-
Fault message ID
805311754 0x3000150A Description
Severity/responseRAP - Watchdog expired
Warning
-
Fault message ID
805311755 0x3000150B Description
Severity/responseRAP - Connecting 2nd server denied, multi server support is disabled
Warning
-
Fault message ID
805311756 0x3000150C Description
Severity/responseRAP - Logon aborted
Warning
-
Fault message ID
805311757 0x3000150D Description
Severity/responseRAP - Invalid version
Warning
-
Fault message ID
805311769 0x30001519 Description
Severity/responseRAP - Server stopped
Warning
-
Fault message ID
805311770 0x3000151A Description
Severity/responseRAP - Watchdog expired
Warning
-
Fault message ID
805311771 0x3000151B Description
Severity/responseRAP - Reconnect time expired
Warning
-
Fault message ID
805311772 0x3000151C Description
Severity/responseRAP - Client logged on
Warning
-
Fault message ID
805311773 0x3000151D Description
Severity/responseRAP - Client reconnected
Warning
-
Fault message ID
805311774 0x3000151E Description
Severity/responseRAP - Socket changed after reconnect
Warning
-
Fault message ID
805311817 0x30001549 Description
Severity/responseDCM - Init function not called or call not successful
Warning
-
Fault message ID
805311818 0x3000154A Description
Severity/responseDCM - Controller error - synchronization out of limit
Warning
-
Fault message ID
805311819 0x3000154B Description
Severity/responseDCM - Not enough memory
Warning
-
Fault message ID
805311820 0x3000154C Description
Severity/responseDCM - Hardware layer - (BSP) invalid
Warning
-
Fault message ID
805311821 0x3000154D Description
Severity/responseDCM - Hardware layer - Error while modifying the timer
Warning
-
Fault message ID
805311822 0x3000154E Description
Severity/responseDCM - Hardware layer - Timer is not running
Warning
-
Fault message ID
805311823 0x3000154F Description
Severity/responseDCM - Hardware layer - Function is called on wrong CPU
Warning
-
Fault message ID
805311881 0x30001589 Description
CauseEtherCAT - State change of master successful
RemedyEtherCAT - State change of master successful
Severity/responseFor information only. No remedy necessary.
Warning
-
Fault message ID
805311882 0x3000158A Description
CauseEtherCAT - Bus scan successful
RemedyEtherCAT - Bus scan successful
Severity/responseFor information only. No remedy necessary.
Warning
-
Fault message ID
805311883 0x3000158B Description
CauseEtherCAT - Bus scan error
RemedyError in the network topology
Severity/responseCheck network topology.
Warning
-
Fault message ID
805311884 0x3000158C Description
Severity/responseEtherCAT - Distributed clocks state
Warning
-
Fault message ID
805311885 0x3000158D Description
Severity/responseEtherCAT - Distributed clocks - Latching state
Warning
-
Fault message ID
805311886 0x3000158E Description
CauseCoE - SDO download failure
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
Fault message ID
805311887 0x3000158F Description
CauseCoE - SDO upload failure
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
Fault message ID
805311888 0x30001590 Description
CauseCoE - OD-list upload failure
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
0x2836:003
Parameter
Manual control mode: Ramp time (current) Data type
U16 Default setting
0 ms Attributes
- -
0x2836:004
Parameter
Manual control mode: Ramp time (frequency) Data type
U16 Default setting
500 ms Attributes
- -
0x2836:005
Parameter
Manual control mode: Time monitoring (frequency) Data type
U32 Default setting
2500 ms Attributes
- -
0x2836:006
Parameter
Manual control mode: Current controller gain Data type
U32 Default setting
20.00 V/A Attributes
- -
0x2836:007
Parameter
Manual control mode: Current controller reset time Data type
U32 Default setting
20.00 ms Attributes
- -
0x2840
Parameter
Error reset time Data type
I32 Default setting
x ms (Read only) Attributes
- -
0x2841
Parameter
Reset error Data type
U8 Default setting
0 Attributes
- -
0x284E:001
Parameter
Additional error information: Component ID Data type
U16 Default setting
- (Read only) Attributes
- -
0x284F
Parameter
Current error Data type
OCTET[64] Default setting
- (Read only) Attributes
- -
0x2857:001
Parameter
CANopen monitoring: RPDO1-Timeout Data type
U8 Default setting
Warning [2] Attributes
- -
0x2857:002
Parameter
CANopen monitoring: RPDO2-Timeout Data type
U8 Default setting
Warning [2] Attributes
- -
0x2857:003
Parameter
CANopen monitoring: RPDO3-Timeout Data type
U8 Default setting
Warning [2] Attributes
- -
0x2857:004
Parameter
CANopen monitoring: RPDO4-Timeout Data type
U8 Default setting
Warning [2] Attributes
- -
0x2857:005
Parameter
CANopen monitoring: Heartbeat-Timeout Consumer 1 Data type
U8 Default setting
Warning [2] Attributes
- -
0x2857:006
Parameter
CANopen monitoring: Heartbeat-Timeout Consumer 2 Data type
U8 Default setting
Warning [2] Attributes
- -
0x2857:007
Parameter
CANopen monitoring: Heartbeat-Timeout Consumer 3 Data type
U8 Default setting
Warning [2] Attributes
- -
0x2857:008
Parameter
CANopen monitoring: Heartbeat-Timeout Consumer 4 Data type
U8 Default setting
Warning [2] Attributes
- -
0x2857:010
Parameter
CANopen monitoring: "Bus-off" state change Data type
U8 Default setting
Warning [2] Attributes
- -
0x2857:011
Parameter
CANopen monitoring: Warning Data type
U8 Default setting
Warning [2] Attributes
- -
0x2859:001
Parameter
Network monitoring: Watchdog elapsed Data type
U8 Default setting
Warning [2] Attributes
- -
0x2859:002
Parameter
Network monitoring: Data exchange exited Data type
U8 Default setting
No response [0] Attributes
- -
0x2859:003
Parameter
Network monitoring: Invalid configuration Data type
U8 Default setting
Warning [2] Attributes
- -
0x2859:004
Parameter
Network monitoring: Initialisation error Data type
U8 Default setting
Warning [2] Attributes
- -
0x2859:005
Parameter
Network monitoring: Invalid process data Data type
U8 Default setting
Warning [2] Attributes
- -
0x2859:006
Parameter
Network monitoring: Time-out explicit message Data type
U8 Default setting
Warning [2] Attributes
-
No results.