i950
- Rated power 0.37 kW/0.5 HP
- Output current 2.4 A
- Output frequency 0-599 Hz
- Rated mains voltage 1/N(3)/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 0.55 kW/0.75 HP
- Output current 3.2 A
- Output frequency 0-599 Hz
- Rated mains voltage 1/N(3)/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 0.55 kW/0.75 HP
- Output current 1.8/1.6 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 0.75 kW/1 HP
- Output current 4.2 A
- Output frequency 0-599 Hz
- Rated mains voltage 1/N(3)/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 0.75 kW/1 HP
- Output current 2.4/2.1 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 1.5 kW/2 HP
- Output current 7 A
- Output frequency 0-599 Hz
- Rated mains voltage 1/N(3)/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 2.2 kW/3 HP
- Output current 9.6 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 2.2 kW/3 HP
- Output current 5.6/4.8 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 4 kW/5 HP
- Output current 16.5 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 4 kW/5 HP
- Output current 9.5/8.2 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 5.5 kW/7.5 HP
- Output current 23 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 7.5 kW/10 HP
- Output current 16.5/14 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 11 kW/15 HP
- Output current 23.5/21 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 15 kW/20 HP
- Output current 32/27 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 22 kW/30 HP
- Output current 47/40.4 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 30 kW/40 HP
- Output current 61/52 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 45 kW/60 HP
- Output current 89/77 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 55 kW/75 HP
- Output current 110/96 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 75 kW/100 HP
- Output current 150/124 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 90 kW/125 HP
- Output current 180/156 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 110 kW/150 HP
- Output current 212/180 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
-
Fault message ID
805311754 0x3000150A Description
Severity/responseRAP - Watchdog expired
Warning
-
Fault message ID
805311755 0x3000150B Description
Severity/responseRAP - Connecting 2nd server denied, multi server support is disabled
Warning
-
Fault message ID
805311756 0x3000150C Description
Severity/responseRAP - Logon aborted
Warning
-
Fault message ID
805311757 0x3000150D Description
Severity/responseRAP - Invalid version
Warning
-
Fault message ID
805311769 0x30001519 Description
Severity/responseRAP - Server stopped
Warning
-
Fault message ID
805311770 0x3000151A Description
Severity/responseRAP - Watchdog expired
Warning
-
Fault message ID
805311771 0x3000151B Description
Severity/responseRAP - Reconnect time expired
Warning
-
Fault message ID
805311772 0x3000151C Description
Severity/responseRAP - Client logged on
Warning
-
Fault message ID
805311773 0x3000151D Description
Severity/responseRAP - Client reconnected
Warning
-
Fault message ID
805311774 0x3000151E Description
Severity/responseRAP - Socket changed after reconnect
Warning
-
Fault message ID
805311817 0x30001549 Description
Severity/responseDCM - Init function not called or call not successful
Warning
-
Fault message ID
805311818 0x3000154A Description
Severity/responseDCM - Controller error - synchronization out of limit
Warning
-
Fault message ID
805311819 0x3000154B Description
Severity/responseDCM - Not enough memory
Warning
-
Fault message ID
805311820 0x3000154C Description
Severity/responseDCM - Hardware layer - (BSP) invalid
Warning
-
Fault message ID
805311821 0x3000154D Description
Severity/responseDCM - Hardware layer - Error while modifying the timer
Warning
-
Fault message ID
805311822 0x3000154E Description
Severity/responseDCM - Hardware layer - Timer is not running
Warning
-
Fault message ID
805311823 0x3000154F Description
Severity/responseDCM - Hardware layer - Function is called on wrong CPU
Warning
-
Fault message ID
805311881 0x30001589 Description
CauseEtherCAT - State change of master successful
RemedyEtherCAT - State change of master successful
Severity/responseFor information only. No remedy necessary.
Warning
-
Fault message ID
805311882 0x3000158A Description
CauseEtherCAT - Bus scan successful
RemedyEtherCAT - Bus scan successful
Severity/responseFor information only. No remedy necessary.
Warning
-
Fault message ID
805311883 0x3000158B Description
CauseEtherCAT - Bus scan error
RemedyError in the network topology
Severity/responseCheck network topology.
Warning
-
Fault message ID
805311884 0x3000158C Description
Severity/responseEtherCAT - Distributed clocks state
Warning
-
Fault message ID
805311885 0x3000158D Description
Severity/responseEtherCAT - Distributed clocks - Latching state
Warning
-
Fault message ID
805311886 0x3000158E Description
CauseCoE - SDO download failure
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
Fault message ID
805311887 0x3000158F Description
CauseCoE - SDO upload failure
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
Fault message ID
805311888 0x30001590 Description
CauseCoE - OD-list upload failure
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
0x2822:029
Parameter
Axis commands: Get load encoder/master encoder characteristic (resolver) Data type
U8 Default setting
Off/Ready [0] Attributes
- -
0x2822:030
Parameter
Axis commands: Get load encoder/master encoder information (HIPERFACE®) Data type
U8 Default setting
Off/Ready [0] Attributes
- -
0x2822:037
Parameter
Axis commands: Estimate all motor parameters based on rated data Data type
U8 Default setting
Off/Ready [0] Attributes
- -
0x2822:038
Parameter
Axis commands: HIPERFACE (A): Set position with synchronization Data type
U8 Default setting
Off/Ready [0] Attributes
- -
0x2822:039
Parameter
Axis commands: HIPERFACE (A): Set position with synchronization Data type
U8 Default setting
Off/Ready [0] Attributes
- -
0x2822:042
Parameter
Axis commands: Calculate speed filter time constant Data type
U8 Default setting
Off/Ready [0] Attributes
- -
0x2822:043
Parameter
Axis commands: Load power dependent motor parameters Data type
U8 Default setting
RANLI_C2822_S043_GEN_V00000000 [0] Attributes
- -
0x2822:044
Parameter
Axis commands: Cogging torque compensation Data type
U8 Default setting
RANLI_C2822_S044_GEN_V00000000 [0] Attributes
- -
0x2823
Parameter
Status of axis commands Data type
U8 Default setting
x % (Read only) Attributes
- -
0x2824
Parameter
Control via PDO/Application Data type
U8 Default setting
Keypad [1] Attributes
C -
0x2825
Parameter
Drive mode selection Data type
U8 Default setting
CiA402 operating modes [0] Attributes
C -
0x2826
Parameter
Timeout for error response -> quickstop Data type
U32 Default setting
4 s Attributes
- -
0x282A:001
Parameter
Status words: Cause of disable Data type
U32 Default setting
- (Read only) Attributes
H -
0x282A:004
Parameter
Status words: Extended status word Data type
U16 Default setting
- (Read only) Attributes
H -
0x282C:001
Parameter
I/O diagnostic: Application level of the digital inputs Data type
U32 Default setting
- (Read only) Attributes
H -
0x282C:002
Parameter
I/O diagnostic: Digital output levels Data type
U32 Default setting
- (Read only) Attributes
H -
0x2830
Parameter
Inverter control word Data type
U16 Default setting
0x0000 Attributes
H -
0x2831
Parameter
Inverter status word Data type
U16 Default setting
- (Read only) Attributes
H -
0x2832
Parameter
Identification status Data type
U16 Default setting
- (Read only) Attributes
H -
0x2833
Parameter
Inverter status word 2 Data type
U16 Default setting
- (Read only) Attributes
H -
0x2835:001
Parameter
Manual test mode: Current setpoint Data type
I16 Default setting
0 % Attributes
- -
0x2835:002
Parameter
Manual test mode: Frequency Data type
I16 Default setting
0.0 Hz Attributes
- -
0x2835:003
Parameter
Manual test mode: Starting angle Data type
I16 Default setting
0.0 ° Attributes
- -
0x2836:001
Parameter
Manual control mode: Current setpoint Data type
U16 Default setting
30 % Attributes
- -
0x2836:002
Parameter
Manual control mode: Frequency Data type
I16 Default setting
0.0 Hz Attributes
-
No results.