i950

i950-C0.37/230-2 i950-C0.37/230-2 Description
Lenze logo Order code / SKU
On request
  • Rated power 0.37 kW/0.5 HP
  • Output current 2.4 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 1/N(3)/PE 230/240 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter not integrated
i950-C0.55/230-2 i950-C0.55/230-2 Description
Lenze logo Order code / SKU
On request
  • Rated power 0.55 kW/0.75 HP
  • Output current 3.2 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 1/N(3)/PE 230/240 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter not integrated
i950-C0.55/400-3 i950-C0.55/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 0.55 kW/0.75 HP
  • Output current 1.8/1.6 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter Integrated
i950-C0.75/230-2 i950-C0.75/230-2 Description
Lenze logo Order code / SKU
On request
  • Rated power 0.75 kW/1 HP
  • Output current 4.2 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 1/N(3)/PE 230/240 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter not integrated
i950-C0.75/400-3 i950-C0.75/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 0.75 kW/1 HP
  • Output current 2.4/2.1 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter Integrated
i950-C1.5/230-2 i950-C1.5/230-2 Description
Lenze logo Order code / SKU
On request
  • Rated power 1.5 kW/2 HP
  • Output current 7 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 1/N(3)/PE 230/240 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter not integrated
i950-C2.2/230-3 i950-C2.2/230-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 2.2 kW/3 HP
  • Output current 9.6 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 230/240 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter not integrated
i950-C2.2/400-3 i950-C2.2/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 2.2 kW/3 HP
  • Output current 5.6/4.8 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter Integrated
i950-C4/230-3 i950-C4/230-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 4 kW/5 HP
  • Output current 16.5 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 230/240 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter not integrated
i950-C4/400-3 i950-C4/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 4 kW/5 HP
  • Output current 9.5/8.2 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter Integrated
i950-C5.5/230-3 i950-C5.5/230-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 5.5 kW/7.5 HP
  • Output current 23 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 230/240 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter not integrated
i950-C7.5/400-3 i950-C7.5/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 7.5 kW/10 HP
  • Output current 16.5/14 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter Integrated
i950-C11/400-3 i950-C11/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 11 kW/15 HP
  • Output current 23.5/21 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter Integrated
i950-C15/400-3 i950-C15/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 15 kW/20 HP
  • Output current 32/27 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter Integrated
i950-C22/400-3 i950-C22/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 22 kW/30 HP
  • Output current 47/40.4 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter Integrated
i950-C30/400-3 i950-C30/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 30 kW/40 HP
  • Output current 61/52 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter Integrated
i950-C45/400-3 i950-C45/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 45 kW/60 HP
  • Output current 89/77 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter Integrated
i950-C55/400-3 i950-C55/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 55 kW/75 HP
  • Output current 110/96 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter Integrated
i950-C75/400-3 i950-C75/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 75 kW/100 HP
  • Output current 150/124 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter Integrated
i950-C90/400-3 i950-C90/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 90 kW/125 HP
  • Output current 180/156 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter Integrated
i950-C110/400-3 i950-C110/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 110 kW/150 HP
  • Output current 212/180 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter Integrated
Showing 301–325 of 563
  • Fault message ID
    805311459
    0x300013E3 Description

    CoE- SDO Abort 'Actual device state - Data cannot be transferred/stored in application (0x08000022)'

    Cause

    Access denied.

    Remedy

    Check access authorization. Check object properties.

    Severity/response

    Warning

  • Fault message ID
    805311460
    0x300013E4 Description

    CoE - SDO Abort 'Object dictionary - Dynamic generation fails or object dictionary is missing (0x08000023)'

    Cause

    Access denied.

    Remedy

    Check access authorization. Check object properties.

    Severity/response

    Warning

  • Fault message ID
    805311461
    0x300013E5 Description

    CoE - SDO Abort 'Unknown abort code'

    Cause

    Access denied.

    Remedy

    Check access authorization. Check object properties.

    Severity/response

    Warning

  • Fault message ID
    805311462
    0x300013E6 Description

    CoE - Invalid parameter

    Cause

    Access denied.

    Remedy

    Check access authorization. Check object properties. Check transfer properties.

    Severity/response

    Warning

  • Fault message ID
    805311463
    0x300013E7 Description

    CoE - CoE protocol not supported

    Cause

    Access denied.

    Remedy

    Check access authorization. Check object properties. Check transfer properties.

    Severity/response

    Warning

  • Fault message ID
    805311464
    0x300013E8 Description

    CoE - Unknown FoE error

    Cause

    Access denied.

    Remedy

    Check access authorization. Check file. Check transfer properties.

    Severity/response

    Warning

  • Fault message ID
    805311465
    0x300013E9 Description

    CoE - FoE error 'Not found'

    Cause

    Access denied.

    Remedy

    Check access authorization. Check file. Check transfer properties.

    Severity/response

    Warning

  • Fault message ID
    805311466
    0x300013EA Description

    CoE - FoE error 'Access denied'

    Cause

    Access denied.

    Remedy

    Check access authorization. Check file. Check transfer properties.

    Severity/response

    Warning

  • Fault message ID
    805311467
    0x300013EB Description

    CoE - FoE error 'Disk full'

    Cause

    Access denied.

    Remedy

    Check access authorization. Check file. Check transfer properties.

    Severity/response

    Warning

  • Fault message ID
    805311468
    0x300013EC Description

    CoE - FoE error 'Illegal'

    Cause

    Access denied.

    Remedy

    Check access authorization. Check file. Check transfer properties.

    Severity/response

    Warning

  • Fault message ID
    805311469
    0x300013ED Description

    CoE - FoE error 'Wrong packet number'

    Cause

    Internal error

    Remedy

    Restart the device. If the error persists, contact the manufacturer.

    Severity/response

    Warning

  • Fault message ID
    805311470
    0x300013EE Description

    CoE - FoE error 'Already existing'

    Cause

    Access denied.

    Remedy

    Check access authorization. Check file. Check transfer properties.

    Severity/response

    Warning

  • Fault message ID
    805311471
    0x300013EF Description

    CoE - FoE error 'User missing'

    Cause

    Access denied.

    Remedy

    Check access authorization. Check file. Check transfer properties.

    Severity/response

    Warning

  • Fault message ID
    805311472
    0x300013F0 Description

    CoE - FoE error 'Only possible in bootstrap'

    Cause

    Access denied.

    Remedy

    Check access authorization. Check file. Check transfer properties.

    Severity/response

    Warning

  • Fault message ID
    805311473
    0x300013F1 Description

    CoE - FoE error 'No bootstrap'

    Cause

    Access denied.

    Remedy

    Check access authorization. Check file. Check transfer properties.

    Severity/response

    Warning

  • Fault message ID
    805311474
    0x300013F2 Description

    CoE - FoE error 'No access rights'

    Cause

    Access denied.

    Remedy

    Check access authorization. Check file. Check transfer properties.

    Severity/response

    Warning

  • Fault message ID
    805311475
    0x300013F3 Description

    CoE - FoE error 'Program error'

    Cause

    Access denied.

    Remedy

    Check access authorization. Check object properties.

    Severity/response

    Warning

  • Fault message ID
    805311476
    0x300013F4 Description

    CoE - FoE error 'Invalid parameter'

    Cause

    Access denied.

    Remedy

    Check access authorization. Check file. Check transfer properties.

    Severity/response

    Warning

  • Fault message ID
    805311480
    0x300013F8 Description

    CTRL - Master configuration not found

    Cause

    Internal error

    Remedy

    Restart the device. If the error persists, contact the manufacturer.

    Severity/response

    Warning

  • Fault message ID
    805311481
    0x300013F9 Description

    SLV - Command error while EEPROM upload

    Cause

    Internal error

    Remedy

    Restart the device. If the error persists, contact the manufacturer.

    Severity/response

    Warning

  • Fault message ID
    805311482
    0x300013FA Description

    SLV - Command error while EEPROM download

    Cause

    Internal error

    Remedy

    Restart the device. If the error persists, contact the manufacturer.

    Severity/response

    Warning

  • Fault message ID
    805311483
    0x300013FB Description

    PRJ - Cyclic command too long

    Cause

    Internal error

    Remedy

    Restart the device. If the error persists, contact the manufacturer.

    Severity/response

    Warning

  • Fault message ID
    805311484
    0x300013FC Description

    PRJ - Invalid input offset in cyc cmd, please check InputOffs

    Cause

    Internal error

    Remedy

    Restart the device. If the error persists, contact the manufacturer.

    Severity/response

    Warning

  • Fault message ID
    805311485
    0x300013FD Description

    PRJ - Invalid output offset in cyc cmd, please check OutputOffs

    Cause

    Internal error

    Remedy

    Restart the device. If the error persists, contact the manufacturer.

    Severity/response

    Warning

  • Fault message ID
    805311753
    0x30001509 Description

    RAP - Invalid cookie

    Severity/response

    Warning

← Previous Page 13 of 23 Next →

No results.