i950
- Rated power 0.37 kW/0.5 HP
- Output current 2.4 A
- Output frequency 0-599 Hz
- Rated mains voltage 1/N(3)/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 0.55 kW/0.75 HP
- Output current 3.2 A
- Output frequency 0-599 Hz
- Rated mains voltage 1/N(3)/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 0.55 kW/0.75 HP
- Output current 1.8/1.6 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 0.75 kW/1 HP
- Output current 4.2 A
- Output frequency 0-599 Hz
- Rated mains voltage 1/N(3)/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 0.75 kW/1 HP
- Output current 2.4/2.1 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 1.5 kW/2 HP
- Output current 7 A
- Output frequency 0-599 Hz
- Rated mains voltage 1/N(3)/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 2.2 kW/3 HP
- Output current 9.6 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 2.2 kW/3 HP
- Output current 5.6/4.8 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 4 kW/5 HP
- Output current 16.5 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 4 kW/5 HP
- Output current 9.5/8.2 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 5.5 kW/7.5 HP
- Output current 23 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 7.5 kW/10 HP
- Output current 16.5/14 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 11 kW/15 HP
- Output current 23.5/21 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 15 kW/20 HP
- Output current 32/27 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 22 kW/30 HP
- Output current 47/40.4 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 30 kW/40 HP
- Output current 61/52 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 45 kW/60 HP
- Output current 89/77 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 55 kW/75 HP
- Output current 110/96 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 75 kW/100 HP
- Output current 150/124 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 90 kW/125 HP
- Output current 180/156 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 110 kW/150 HP
- Output current 212/180 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
-
Fault message ID
805311401 0x300013A9 Description
CausePRJ - Configurator error - cyclic commands are missing in master XML file
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
Fault message ID
805311402 0x300013AA Description
CausePRJ - AL_STATUS register read command is missing in master XML file
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
Fault message ID
805311403 0x300013AB Description
CauseISW - Fatal internal McSm error
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
Fault message ID
805311404 0x300013AC Description
CauseSLV - Slave error
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
Fault message ID
805311405 0x300013AD Description
CauseSLV - Frame lost, IDX mismatch
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
Fault message ID
805311406 0x300013AE Description
CauseSLV - At least one EtherCAT command is missing in the received frame
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
Fault message ID
805311408 0x300013B0 Description
CauseCTRL - IOCTL EC_IOCTL_DC_LATCH_REQ_LTIMVALS not possible in DC Latching auto read mode
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
Fault message ID
805311409 0x300013B1 Description
CauseSLV - Auto increment address - increment mismatch (slave missing)
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
Fault message ID
805311410 0x300013B2 Description
CauseCTRL - Slave in invalid state, e.g. not in OP (API not callable in this state)
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
Fault message ID
805311411 0x300013B3 Description
CauseSLV - Fixed station address lost or slave missing - FPRD to AL_STATUS failed
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
Fault message ID
805311412 0x300013B4 Description
CausePRJ - Too many cyclic commands in XML configuration file
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
Fault message ID
805311414 0x300013B6 Description
CauseRAP - Master core not accessible
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
Fault message ID
805311415 0x300013B7 Description
CauseSLV - COE mailbox send - WKC error
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
Fault message ID
805311416 0x300013B8 Description
CauseSLV - COE mailbox receive - WKC error
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
Fault message ID
805311417 0x300013B9 Description
CauseCTRL - No mailbox support
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
Fault message ID
805311418 0x300013BA Description
CauseCoE - Protocol not supported
RemedySlave does not support CoE.
Severity/responseUse slave that supports CoE.
Warning
-
Fault message ID
805311419 0x300013BB Description
CausePRJ - EoE protocol not supported
RemedySlave does not support EoE.
Severity/responseUse slave that supports EoE.
Warning
-
Fault message ID
805311420 0x300013BC Description
CauseFoE. Protocol not supported
RemedySlave does not support FoE.
Severity/responseUse slave that supports FoE.
Warning
-
Fault message ID
805311421 0x300013BD Description
CausePRJ - SoE protocol not supported
RemedySlave does not support SoE.
Severity/responseUse slave that supports SoE.
Warning
-
Fault message ID
805311422 0x300013BE Description
CausePRJ - VoE protocol not supported
RemedySlave does not support VoE.
Severity/responseUse slave that supports VoE.
Warning
-
Fault message ID
805311423 0x300013BF Description
Severity/responsePRJ - Configuration violates evaluation limits
Warning
-
Fault message ID
805311424 0x300013C0 Description
Severity/responseCFG - Evaluation time expired
Warning
-
Fault message ID
805311431 0x300013C7 Description
CauseCOE - invalid slave state
RemedyThe slave status is invalid.
Severity/responseCheck if slave is at least PreOperational. Check other access rights.
Warning
-
Fault message ID
805311432 0x300013C8 Description
CauseCoE - SDO Abort 'Toggle bit not alternated (0x05030000)'
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
Fault message ID
805311433 0x300013C9 Description
CauseCoE - SDO Abort 'SDO protocol time-out (0x05040000)'
RemedySDO protocol timeout
Severity/responseCheck if timeout is set too low.
Warning
-
0x211C:001
Parameter
Status bits inputs: SD-In1 Data type
BOOLEAN Default setting
- (Read only) Attributes
- -
0x211C:002
Parameter
Status bits inputs: SD-In2 Data type
BOOLEAN Default setting
- (Read only) Attributes
- -
0x211C:003
Parameter
Status bits inputs: SD-In3 Data type
BOOLEAN Default setting
- (Read only) Attributes
- -
0x211C:004
Parameter
Status bits inputs: SD-In4 Data type
BOOLEAN Default setting
- (Read only) Attributes
- -
0x211C:005
Parameter
Status bits inputs: AIS Dig-In Data type
BOOLEAN Default setting
- (Read only) Attributes
- -
0x211C:006
Parameter
Status bits inputs: AIE Dig-In Data type
BOOLEAN Default setting
- (Read only) Attributes
- -
0x211C:007
Parameter
Status bits inputs: IRS Dig-In Data type
BOOLEAN Default setting
- (Read only) Attributes
- -
0x211C:008
Parameter
Status bits inputs: IRL Dig-In Data type
BOOLEAN Default setting
- (Read only) Attributes
- -
0x2120:001
Parameter
SD-Out: SD-Out1 source S-Bus Data type
U8 Default setting
Disabled [0] Attributes
- -
0x2121:001
Parameter
SD-Out: SD-Out1 logic function Data type
U8 Default setting
OR [0] Attributes
- -
0x2122
Parameter
Output image Data type
U16 Default setting
- (Read only) Attributes
H -
0x2123:001
Parameter
Status bits outputs: SD-Out1 Data type
BOOLEAN Default setting
- (Read only) Attributes
- -
0x2124
Parameter
CAS Source SD-In Data type
U8 Default setting
Disabled [0] Attributes
- -
0x2125:001
Parameter
CAS: Stop delay Data type
U16 Default setting
x ms (Read only) Attributes
- -
0x2128
Parameter
S-Bus configuration Data type
U8 Default setting
No safety bus [0] Attributes
- -
0x2129:001
Parameter
S-Bus control bits: SD-Out1 Data type
BOOLEAN Default setting
- (Read only) Attributes
- -
0x212A:001
Parameter
S-Bus: FSoE project CRC Data type
U32 Attributes
- -
0x212A:002
Parameter
S-Bus: PROFIsafe status Data type
U8 Default setting
- (Read only) Attributes
- -
0x212A:003
Parameter
S-Bus: PROFIsafe status byte Data type
U8 Default setting
- (Read only) Attributes
H -
0x212A:004
Parameter
S-Bus: PROFIsafe control byte Data type
U8 Default setting
- (Read only) Attributes
H -
0x212C:001
Parameter
Safety software: Firmware version Data type
STRING[50] Default setting
- (Read only) Attributes
- -
0x212D:001
Parameter
Safety hardware: Hardware version Data type
STRING[50] Default setting
- (Read only) Attributes
- -
0x212D:002
Parameter
Safety hardware: Product code Data type
STRING[50] Default setting
- (Read only) Attributes
- -
0x212D:003
Parameter
Safety hardware: Serial number Data type
STRING[50] Default setting
- (Read only) Attributes
- -
0x212D:004
Parameter
Safety hardware: Production date Data type
STRING[50] Default setting
- (Read only) Attributes
-
No results.