i950
- Rated power 0.37 kW/0.5 HP
- Output current 2.4 A
- Output frequency 0-599 Hz
- Rated mains voltage 1/N(3)/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 0.55 kW/0.75 HP
- Output current 3.2 A
- Output frequency 0-599 Hz
- Rated mains voltage 1/N(3)/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 0.55 kW/0.75 HP
- Output current 1.8/1.6 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 0.75 kW/1 HP
- Output current 4.2 A
- Output frequency 0-599 Hz
- Rated mains voltage 1/N(3)/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 0.75 kW/1 HP
- Output current 2.4/2.1 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 1.5 kW/2 HP
- Output current 7 A
- Output frequency 0-599 Hz
- Rated mains voltage 1/N(3)/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 2.2 kW/3 HP
- Output current 9.6 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 2.2 kW/3 HP
- Output current 5.6/4.8 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 4 kW/5 HP
- Output current 16.5 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 4 kW/5 HP
- Output current 9.5/8.2 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 5.5 kW/7.5 HP
- Output current 23 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 7.5 kW/10 HP
- Output current 16.5/14 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 11 kW/15 HP
- Output current 23.5/21 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 15 kW/20 HP
- Output current 32/27 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 22 kW/30 HP
- Output current 47/40.4 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 30 kW/40 HP
- Output current 61/52 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 45 kW/60 HP
- Output current 89/77 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 55 kW/75 HP
- Output current 110/96 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 75 kW/100 HP
- Output current 150/124 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 90 kW/125 HP
- Output current 180/156 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 110 kW/150 HP
- Output current 212/180 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
-
Fault message ID
805311401 0x300013A9 Description
CausePRJ - Configurator error - cyclic commands are missing in master XML file
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
Fault message ID
805311402 0x300013AA Description
CausePRJ - AL_STATUS register read command is missing in master XML file
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
Fault message ID
805311403 0x300013AB Description
CauseISW - Fatal internal McSm error
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
Fault message ID
805311404 0x300013AC Description
CauseSLV - Slave error
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
Fault message ID
805311405 0x300013AD Description
CauseSLV - Frame lost, IDX mismatch
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
Fault message ID
805311406 0x300013AE Description
CauseSLV - At least one EtherCAT command is missing in the received frame
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
Fault message ID
805311408 0x300013B0 Description
CauseCTRL - IOCTL EC_IOCTL_DC_LATCH_REQ_LTIMVALS not possible in DC Latching auto read mode
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
Fault message ID
805311409 0x300013B1 Description
CauseSLV - Auto increment address - increment mismatch (slave missing)
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
Fault message ID
805311410 0x300013B2 Description
CauseCTRL - Slave in invalid state, e.g. not in OP (API not callable in this state)
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
Fault message ID
805311411 0x300013B3 Description
CauseSLV - Fixed station address lost or slave missing - FPRD to AL_STATUS failed
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
Fault message ID
805311412 0x300013B4 Description
CausePRJ - Too many cyclic commands in XML configuration file
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
Fault message ID
805311414 0x300013B6 Description
CauseRAP - Master core not accessible
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
Fault message ID
805311415 0x300013B7 Description
CauseSLV - COE mailbox send - WKC error
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
Fault message ID
805311416 0x300013B8 Description
CauseSLV - COE mailbox receive - WKC error
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
Fault message ID
805311417 0x300013B9 Description
CauseCTRL - No mailbox support
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
Fault message ID
805311418 0x300013BA Description
CauseCoE - Protocol not supported
RemedySlave does not support CoE.
Severity/responseUse slave that supports CoE.
Warning
-
Fault message ID
805311419 0x300013BB Description
CausePRJ - EoE protocol not supported
RemedySlave does not support EoE.
Severity/responseUse slave that supports EoE.
Warning
-
Fault message ID
805311420 0x300013BC Description
CauseFoE. Protocol not supported
RemedySlave does not support FoE.
Severity/responseUse slave that supports FoE.
Warning
-
Fault message ID
805311421 0x300013BD Description
CausePRJ - SoE protocol not supported
RemedySlave does not support SoE.
Severity/responseUse slave that supports SoE.
Warning
-
Fault message ID
805311422 0x300013BE Description
CausePRJ - VoE protocol not supported
RemedySlave does not support VoE.
Severity/responseUse slave that supports VoE.
Warning
-
Fault message ID
805311423 0x300013BF Description
Severity/responsePRJ - Configuration violates evaluation limits
Warning
-
Fault message ID
805311424 0x300013C0 Description
Severity/responseCFG - Evaluation time expired
Warning
-
Fault message ID
805311431 0x300013C7 Description
CauseCOE - invalid slave state
RemedyThe slave status is invalid.
Severity/responseCheck if slave is at least PreOperational. Check other access rights.
Warning
-
Fault message ID
805311432 0x300013C8 Description
CauseCoE - SDO Abort 'Toggle bit not alternated (0x05030000)'
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
Fault message ID
805311433 0x300013C9 Description
CauseCoE - SDO Abort 'SDO protocol time-out (0x05040000)'
RemedySDO protocol timeout
Severity/responseCheck if timeout is set too low.
Warning
-
0x2822:029
Parameter
Axis commands: Get load encoder/master encoder characteristic (resolver) Data type
U8 Default setting
Off/Ready [0] Attributes
- -
0x2822:030
Parameter
Axis commands: Get load encoder/master encoder information (HIPERFACE®) Data type
U8 Default setting
Off/Ready [0] Attributes
- -
0x2822:037
Parameter
Axis commands: Estimate all motor parameters based on rated data Data type
U8 Default setting
Off/Ready [0] Attributes
- -
0x2822:038
Parameter
Axis commands: HIPERFACE (A): Set position with synchronization Data type
U8 Default setting
Off/Ready [0] Attributes
- -
0x2822:039
Parameter
Axis commands: HIPERFACE (A): Set position with synchronization Data type
U8 Default setting
Off/Ready [0] Attributes
- -
0x2822:042
Parameter
Axis commands: Calculate speed filter time constant Data type
U8 Default setting
Off/Ready [0] Attributes
- -
0x2822:043
Parameter
Axis commands: Load power dependent motor parameters Data type
U8 Default setting
RANLI_C2822_S043_GEN_V00000000 [0] Attributes
- -
0x2822:044
Parameter
Axis commands: Cogging torque compensation Data type
U8 Default setting
RANLI_C2822_S044_GEN_V00000000 [0] Attributes
- -
0x2823
Parameter
Status of axis commands Data type
U8 Default setting
x % (Read only) Attributes
- -
0x2824
Parameter
Control via PDO/Application Data type
U8 Default setting
Keypad [1] Attributes
C -
0x2825
Parameter
Drive mode selection Data type
U8 Default setting
CiA402 operating modes [0] Attributes
C -
0x2826
Parameter
Timeout for error response -> quickstop Data type
U32 Default setting
4 s Attributes
- -
0x282A:001
Parameter
Status words: Cause of disable Data type
U32 Default setting
- (Read only) Attributes
H -
0x282A:004
Parameter
Status words: Extended status word Data type
U16 Default setting
- (Read only) Attributes
H -
0x282C:001
Parameter
I/O diagnostic: Application level of the digital inputs Data type
U32 Default setting
- (Read only) Attributes
H -
0x282C:002
Parameter
I/O diagnostic: Digital output levels Data type
U32 Default setting
- (Read only) Attributes
H -
0x2830
Parameter
Inverter control word Data type
U16 Default setting
0x0000 Attributes
H -
0x2831
Parameter
Inverter status word Data type
U16 Default setting
- (Read only) Attributes
H -
0x2832
Parameter
Identification status Data type
U16 Default setting
- (Read only) Attributes
H -
0x2833
Parameter
Inverter status word 2 Data type
U16 Default setting
- (Read only) Attributes
H -
0x2835:001
Parameter
Manual test mode: Current setpoint Data type
I16 Default setting
0 % Attributes
- -
0x2835:002
Parameter
Manual test mode: Frequency Data type
I16 Default setting
0.0 Hz Attributes
- -
0x2835:003
Parameter
Manual test mode: Starting angle Data type
I16 Default setting
0.0 ° Attributes
- -
0x2836:001
Parameter
Manual control mode: Current setpoint Data type
U16 Default setting
30 % Attributes
- -
0x2836:002
Parameter
Manual control mode: Frequency Data type
I16 Default setting
0.0 Hz Attributes
-
No results.