i950
- Rated power 0.37 kW/0.5 HP
- Output current 2.4 A
- Output frequency 0-599 Hz
- Rated mains voltage 1/N(3)/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 0.55 kW/0.75 HP
- Output current 3.2 A
- Output frequency 0-599 Hz
- Rated mains voltage 1/N(3)/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 0.55 kW/0.75 HP
- Output current 1.8/1.6 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 0.75 kW/1 HP
- Output current 4.2 A
- Output frequency 0-599 Hz
- Rated mains voltage 1/N(3)/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 0.75 kW/1 HP
- Output current 2.4/2.1 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 1.5 kW/2 HP
- Output current 7 A
- Output frequency 0-599 Hz
- Rated mains voltage 1/N(3)/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 2.2 kW/3 HP
- Output current 9.6 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 2.2 kW/3 HP
- Output current 5.6/4.8 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 4 kW/5 HP
- Output current 16.5 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 4 kW/5 HP
- Output current 9.5/8.2 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 5.5 kW/7.5 HP
- Output current 23 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 7.5 kW/10 HP
- Output current 16.5/14 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 11 kW/15 HP
- Output current 23.5/21 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 15 kW/20 HP
- Output current 32/27 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 22 kW/30 HP
- Output current 47/40.4 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 30 kW/40 HP
- Output current 61/52 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 45 kW/60 HP
- Output current 89/77 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 55 kW/75 HP
- Output current 110/96 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 75 kW/100 HP
- Output current 150/124 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 90 kW/125 HP
- Output current 180/156 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 110 kW/150 HP
- Output current 212/180 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
-
Fault message ID
805311369 0x30001389 Description
CauseCTRL - Feature not supported
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
Fault message ID
805311370 0x3000138A Description
CauseCTRL - Invalid index
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
Fault message ID
805311371 0x3000138B Description
CauseISW - Invalid offset
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
Fault message ID
805311373 0x3000138D Description
CauseCTRL - Invalid size
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
Fault message ID
805311374 0x3000138E Description
CauseISW - Invalid data
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
Fault message ID
805311375 0x3000138F Description
CauseISW - Not ready
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
Fault message ID
805311376 0x30001390 Description
CauseCTRL - Busy
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
Fault message ID
805311377 0x30001391 Description
CauseISW - Cannot queue acyclic EtherCAT command
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
Fault message ID
805311378 0x30001392 Description
CauseCFG - No memory left
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
Fault message ID
805311379 0x30001393 Description
CauseCTRL - Invalid parameter
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
Fault message ID
805311380 0x30001394 Description
CauseCTRL - Not found
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
Fault message ID
805311382 0x30001396 Description
CauseISW - Invalid state
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
Fault message ID
805311383 0x30001397 Description
CauseISW - Cannot add slave to timer list
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
Fault message ID
805311384 0x30001398 Description
CauseSLV - Time-out
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
Fault message ID
805311385 0x30001399 Description
CauseISW - Open failed
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
Fault message ID
805311386 0x3000139A Description
CauseLLA - Send failed
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
Fault message ID
805311387 0x3000139B Description
CauseCFG - Error when queuing a mailbox command
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
Fault message ID
805311388 0x3000139C Description
CauseISW - Invalid mailbox command
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
Fault message ID
805311389 0x3000139D Description
CauseISW - Unknown mailbox protocol command
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
Fault message ID
805311390 0x3000139E Description
CauseISW - Access denied
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
Fault message ID
805311394 0x300013A2 Description
CauseCFG - Invalid product key
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
Fault message ID
805311395 0x300013A3 Description
CausePRJ - Wrong format of master XML file
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
Fault message ID
805311396 0x300013A4 Description
CauseCTRL - Function disabled
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
Fault message ID
805311398 0x300013A6 Description
CausePRJ - Mismatch of bus configuration and number of connected slaves
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
Fault message ID
805311399 0x300013A7 Description
CausePRJ - Error reading master XML file
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
0x2B0A:001
Parameter
Oscillation damping: Gain Data type
I16 Default setting
20 % Attributes
- -
0x2B0A:002
Parameter
Oscillation damping: Filter time Data type
U16 Default setting
5 ms Attributes
- -
0x2B0A:003
Parameter
Oscillation damping: Limitation Data type
U16 Default setting
0.2 Hz Attributes
- -
0x2B0A:004
Parameter
Oscillation damping: Final ramp frequency Data type
U8 Default setting
0 % Attributes
- -
0x2B0B
Parameter
Ramp generator frequency Data type
I16 Default setting
x.x Hz (Read only) Attributes
- -
0x2B0C
Parameter
Override field weakening Data type
I16 Default setting
0.0 Hz Attributes
- -
0x2B14:001
Parameter
Gain Data type
U16 Default setting
0.100 Attributes
- -
0x2B14:002
Parameter
Reset time Data type
U16 Default setting
100.0 ms Attributes
- -
0x2B14:003
Parameter
Frequency limitation Data type
U16 Default setting
10.00 Hz Attributes
- -
0x2B80
Parameter
Current for DC-injection braking Data type
U16 Default setting
0.00 A Attributes
- -
0x2BA0
Parameter
Activate flying restart Data type
U8 Default setting
Off [0] Attributes
- -
0x2BA1
Parameter
Flying restart circuit Data type
U16 Default setting
15 % Attributes
- -
0x2BA2
Parameter
Start frequency Data type
I16 Default setting
20.0 Hz Attributes
- -
0x2BA3
Parameter
Integration time Data type
U16 Default setting
600 ms Attributes
- -
0x2BA4
Parameter
Minimum deviation Data type
U16 Default setting
5.00 ° Attributes
- -
0x2BA5
Parameter
Delay time Data type
U16 Default setting
0 ms Attributes
- -
0x2BA6:001
Parameter
Result: Determined speed [rpm] Data type
I16 Default setting
x rpm (Read only) Attributes
- -
0x2BA6:002
Parameter
Result: Determined speed [n unit] Data type
I32 Default setting
rpm (Read only) Attributes
- -
0x2C00
Parameter
Motor control mode Data type
U8 Default setting
Servo control (SC-PSM) [1] Attributes
C -
0x2C01:001
Parameter
Motor parameters: Number of pole pairs Data type
U8 Default setting
- (Read only) Attributes
- -
0x2C01:002
Parameter
Motor parameters: Stator resistance Data type
U32 Default setting
13.5000 Ω Attributes
- -
0x2C01:003
Parameter
Motor parameters: Stator leakage inductance Data type
U32 Default setting
51.000 mH Attributes
- -
0x2C01:004
Parameter
Motor parameters: Rated speed Data type
U16 Default setting
4050 rpm Attributes
- -
0x2C01:005
Parameter
Motor parameters: Rated frequency Data type
U16 Default setting
270.0 Hz Attributes
- -
0x2C01:006
Parameter
Motor parameters: Rated power Data type
U16 Default setting
0.25 kW Attributes
-
No results.