i950
- Rated power 0.37 kW/0.5 HP
- Output current 2.4 A
- Output frequency 0-599 Hz
- Rated mains voltage 1/N(3)/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 0.55 kW/0.75 HP
- Output current 3.2 A
- Output frequency 0-599 Hz
- Rated mains voltage 1/N(3)/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 0.55 kW/0.75 HP
- Output current 1.8/1.6 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 0.75 kW/1 HP
- Output current 4.2 A
- Output frequency 0-599 Hz
- Rated mains voltage 1/N(3)/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 0.75 kW/1 HP
- Output current 2.4/2.1 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 1.5 kW/2 HP
- Output current 7 A
- Output frequency 0-599 Hz
- Rated mains voltage 1/N(3)/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 2.2 kW/3 HP
- Output current 9.6 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 2.2 kW/3 HP
- Output current 5.6/4.8 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 4 kW/5 HP
- Output current 16.5 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 4 kW/5 HP
- Output current 9.5/8.2 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 5.5 kW/7.5 HP
- Output current 23 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 230/240 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter not integrated
- Rated power 7.5 kW/10 HP
- Output current 16.5/14 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 11 kW/15 HP
- Output current 23.5/21 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 15 kW/20 HP
- Output current 32/27 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 22 kW/30 HP
- Output current 47/40.4 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 30 kW/40 HP
- Output current 61/52 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 45 kW/60 HP
- Output current 89/77 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 55 kW/75 HP
- Output current 110/96 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 75 kW/100 HP
- Output current 150/124 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 90 kW/125 HP
- Output current 180/156 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
- Rated power 110 kW/150 HP
- Output current 212/180 A
- Output frequency 0-599 Hz
- Rated mains voltage 3/PE 400/480 V AC
- Motor output Single axis
- Generation B
- Product series i950 cabinet
- EMC filter Integrated
-
Fault message ID
0 0x00000000 Description
CauseNo error
RemedyNo error
Severity/responseFor information only. No remedy necessary.
Information
-
Fault message ID
537469777 0x20092351 Description
CauseMotor utilization too high (i²xt)
RemedyMotor thermally overloaded, e.g. by an impermissible continuous current or by frequent or too long acceleration processes.
Severity/responseCheck drive sizing. Check the setting in the warning threshold or error threshold.
Fehler > CiA402 (configurable)
Setting parameters: 0x2D50:001
-
Fault message ID
537469824 0x20092380 Description
CauseTrouble - utilization of the power section (ixt) too high
RemedyPower section overloaded.
Severity/responseCheck drive sizing.
Fault
-
Fault message ID
537469825 0x20092381 Description
CauseWarning - Utilization of the power section (ixt) too high
RemedyPower section overloaded.
Severity/responseCheck drive sizing.
Warning
-
Fault message ID
537469828 0x20092384 Description
CauseUltimate motor current reached
RemedyUltimate motor current reached.
Severity/response- Reduce the maximum current of the inverter. 0x6073
- Optimize the current controller. 0x2942
Fault > CiA402 (configurable)
Setting parameters: 0x2D46:002
-
Fault message ID
537469829 0x20092385 Description
CauseParameterized max. motor current > max. device current
RemedyParameterized max. motor current 0x6073 > max. device current 0x2DDF:002
Severity/responseReduce max. motor current. 0x6073
Warning
-
Fault message ID
537469830 0x20092386 Description
CauseClamp is active
RemedyMax. device current has been reached. (Display in 0x2DDF:002)
Severity/response- Select a flatter speed ramp.
- Reduce the load.
- Set Imax controller more dynamically. 0x2B08
Warning
-
Fault message ID
537469833 0x20092389 Description
CauseWarning - device utilization (ixt) too high
RemedyFrequent and too long acceleration processes with overcurrent.
Severity/responseCheck drive sizing.
Warning
-
Fault message ID
537469835 0x2009238B Description
CauseTrouble - Device utilization (ixt) too high
RemedyFrequent and too long acceleration processes with overcurrent.
Severity/responseCheck drive sizing.
Fault
-
Fault message ID
537473409 0x20093181 Description
CauseMains failure
RemedyThe motor was decelerated to standstill via the mains failure control without an undervoltage fault occurring.
Severity/response- Check mains voltage.
- Check mains settings.
- Check fuses.
Fault
-
Fault message ID
537477762 0x20094282 Description
CauseThermal overload of control unit
Remedy- Control card temperature > 100 °C
- Ambient temperature too high
Severity/response- Provide for better cooling.
- Reduce ambient temperature.
Information
-
Fault message ID
537478016 0x20094380 Description
CauseFault - Motor temperature sensor
RemedyMotor PTC error.
Severity/responseConnect PTC or switch off monitoring.
Warning (configurable)
Setting parameters: 0x2D49:002
-
Fault message ID
537478017 0x20094381 Description
CauseError - Motor temperature monitoring (PTC)
RemedyMotor PTC error.
Severity/responseConnect PTC or switch off monitoring.
Fault > CiA402 (configurable)
Setting parameters: 0x2D48:002
-
Fault message ID
537478018 0x20094382 Description
CauseMotor overtemperature (load encoder/master encoder)
RemedyMotor temperature via load encoder higher than variable temperature limit.
Severity/responseConnect PTC or switch off monitoring. Set a higher warning threshold (0x2D49:003) and/or error threshold (0x2D49:004).
Warning (configurable)
Setting parameters: 0x2D49:002
-
Fault message ID
537478019 0x20094383 Description
CauseMotor temperature sensor error (load encoder/master encoder)
RemedyMotor PTC error.
Severity/responseConnect PTC or switch off monitoring.
Warning (configurable)
Setting parameters: 0x2D49:002
-
Fault message ID
537485328 0x20096010 Description
CauseInternal error
RemedyInternal error
Severity/responseRestart the device. If the error persists, contact the manufacturer.
Warning
-
Fault message ID
537486096 0x20096310 Description
CauseIncorrect parameter set download
RemedyCRC error in the parameter set detected. Vendor, product code or OBD revision are different. The parameter set is unknown.
Severity/responseRecreate parameter set. Repeat parameter set download.
Warning
-
Fault message ID
537486112 0x20096320 Description
CauseParameter error in object
RemedyUnknown index in the parameter set.
Severity/responseRecreate parameter set.
Warning
-
Fault message ID
537489584 0x200970B0 Description
CauseConnected network option is not supported
RemedyThe network option plugged into the inverter is not supported by the firmware.
Severity/responseUpdate the firmware to a version that supports the network option. Use the network option supported by the current firmware version.
Fault
-
Fault message ID
537490179 0x20097303 Description
CauseFault - Motor feedback
RemedyDefective encoder cable. Defective encoder.
Severity/responseCheck encoder cable. Check encoder. Switch off monitoring if no encoder is used.
Fault > CiA402 (configurable)
Setting parameters: 0x2C45
-
Fault message ID
537490180 0x20097304 Description
CauseError - Load encoder/master encoder
RemedyDefective encoder cable. Defective encoder.
Severity/responseCheck encoder cable. Check encoder. Switch off monitoring if no encoder is used.
Fault > CiA402 (configurable)
Setting parameters: 0x2C55
-
Fault message ID
537490304 0x20097380 Description
CauseMotor encoder - Communication error
RemedyThe communication to an encoder is disturbed.
Severity/responseCheck the supply voltage of the encoder. (0x2C42:002) Check encoder cable.
Fault > CiA402 (configurable)
Setting parameters: 0x2C41:004
-
Fault message ID
537490305 0x20097381 Description
CauseMotor encoder - wrong absolute value because motor speed is too high
RemedyThe absolute encoder position cannot be accepted as the motor rotates too fast.
Severity/responseLet the motor coast.
Fault > CiA402 (configurable)
Setting parameters: 0x2C41:004
-
Fault message ID
537490306 0x20097382 Description
CauseLoad encoder/master encoder - Communication error
RemedyThe communication to an encoder is disturbed.
Severity/responseCheck the supply voltage of the encoder. (0x2C42:002) Check encoder cable.
Fault > CiA402 (configurable)
Setting parameters: 0x2C51:004
-
Fault message ID
537490307 0x20097383 Description
CauseLoad encoder/master encoder - wrong absolute value because motor speed is too high
RemedyThe absolute encoder position cannot be accepted as the motor rotates too fast.
Severity/responseLet the motor coast.
Fault > CiA402 (configurable)
Setting parameters: 0x2C51:004
-
0x2304:102
Parameter
CANopen settings: TPDO3 - Transmission type Data type
U8 Default setting
255 Attributes
- -
0x2304:103
Parameter
CANopen settings: TPDO3 - Inhibit time Data type
U16 Default setting
0.0 ms Attributes
- -
0x2304:105
Parameter
CANopen settings: TPDO3 - Event timer Data type
U16 Default setting
0 ms Attributes
- -
0x2304:111
Parameter
CANopen settings: TPDO4 - COB-ID Data type
U32 Default setting
0xC0000481 Attributes
H -
0x2304:112
Parameter
CANopen settings: TPDO4 - Transmission type Data type
U8 Default setting
255 Attributes
- -
0x2304:113
Parameter
CANopen settings: TPDO4 - Inhibit time Data type
U16 Default setting
0.0 ms Attributes
- -
0x2304:115
Parameter
CANopen settings: TPDO4 - Event timer Data type
U16 Default setting
0 ms Attributes
- -
0x2307
Parameter
CANopen time-out status Data type
U32 Default setting
- (Read only) Attributes
H -
0x2308
Parameter
CANopen status Data type
U16 Default setting
- (Read only) Attributes
- -
0x2309
Parameter
CANopen controller status Data type
U16 Default setting
- (Read only) Attributes
- -
0x230A:001
Parameter
CANopen statistics: PDO1 received Data type
U16 Default setting
- (Read only) Attributes
- -
0x230A:002
Parameter
CANopen statistics: PDO2 received Data type
U16 Default setting
- (Read only) Attributes
- -
0x230A:003
Parameter
CANopen statistics: PDO3 received Data type
U16 Default setting
- (Read only) Attributes
- -
0x230A:004
Parameter
CANopen statistics: POD3 received Data type
U16 Default setting
- (Read only) Attributes
- -
0x230A:005
Parameter
CANopen statistics: PDO1 transmitted Data type
U16 Default setting
- (Read only) Attributes
- -
0x230A:006
Parameter
CANopen statistics: PDO2 transmitted Data type
U16 Default setting
- (Read only) Attributes
- -
0x230A:007
Parameter
CANopen statistics: PDO3 transmitted Data type
U16 Default setting
- (Read only) Attributes
- -
0x230A:008
Parameter
CANopen statistics: PDO4 transmitted Data type
U16 Default setting
- (Read only) Attributes
- -
0x230A:009
Parameter
CANopen statistics: SDO1 telegrams Data type
U16 Default setting
- (Read only) Attributes
- -
0x230A:010
Parameter
CANopen statistics: SDO2 telegrams Data type
U16 Default setting
- (Read only) Attributes
- -
0x230A:013
Parameter
CANopen statistics: Sync - Deviation Data type
I32 Default setting
- (Read only) Attributes
- -
0x230A:014
Parameter
CANopen statistics: Sync - Phase position distance Data type
I32 Default setting
- (Read only) Attributes
- -
0x230B
Parameter
CANopen error counter Data type
U16 Default setting
- (Read only) Attributes
- -
0x231F:001
Parameter
Communication module ID: Active module ID Data type
U8 Default setting
- (Read only) Attributes
- -
0x231F:002
Parameter
Communication module ID: Module ID connected Data type
U8 Default setting
- (Read only) Attributes
-
No results.