i950

i950-C0.37/230-2 i950-C0.37/230-2 Description
Lenze logo Order code / SKU
On request
  • Rated power 0.37 kW/0.5 HP
  • Output current 2.4 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 1/N(3)/PE 230/240 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter not integrated
i950-C0.55/230-2 i950-C0.55/230-2 Description
Lenze logo Order code / SKU
On request
  • Rated power 0.55 kW/0.75 HP
  • Output current 3.2 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 1/N(3)/PE 230/240 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter not integrated
i950-C0.55/400-3 i950-C0.55/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 0.55 kW/0.75 HP
  • Output current 1.8/1.6 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter Integrated
i950-C0.75/230-2 i950-C0.75/230-2 Description
Lenze logo Order code / SKU
On request
  • Rated power 0.75 kW/1 HP
  • Output current 4.2 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 1/N(3)/PE 230/240 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter not integrated
i950-C0.75/400-3 i950-C0.75/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 0.75 kW/1 HP
  • Output current 2.4/2.1 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter Integrated
i950-C1.5/230-2 i950-C1.5/230-2 Description
Lenze logo Order code / SKU
On request
  • Rated power 1.5 kW/2 HP
  • Output current 7 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 1/N(3)/PE 230/240 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter not integrated
i950-C2.2/230-3 i950-C2.2/230-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 2.2 kW/3 HP
  • Output current 9.6 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 230/240 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter not integrated
i950-C2.2/400-3 i950-C2.2/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 2.2 kW/3 HP
  • Output current 5.6/4.8 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter Integrated
i950-C4/230-3 i950-C4/230-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 4 kW/5 HP
  • Output current 16.5 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 230/240 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter not integrated
i950-C4/400-3 i950-C4/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 4 kW/5 HP
  • Output current 9.5/8.2 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter Integrated
i950-C5.5/230-3 i950-C5.5/230-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 5.5 kW/7.5 HP
  • Output current 23 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 230/240 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter not integrated
i950-C7.5/400-3 i950-C7.5/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 7.5 kW/10 HP
  • Output current 16.5/14 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter Integrated
i950-C11/400-3 i950-C11/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 11 kW/15 HP
  • Output current 23.5/21 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter Integrated
i950-C15/400-3 i950-C15/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 15 kW/20 HP
  • Output current 32/27 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter Integrated
i950-C22/400-3 i950-C22/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 22 kW/30 HP
  • Output current 47/40.4 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter Integrated
i950-C30/400-3 i950-C30/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 30 kW/40 HP
  • Output current 61/52 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter Integrated
i950-C45/400-3 i950-C45/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 45 kW/60 HP
  • Output current 89/77 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter Integrated
i950-C55/400-3 i950-C55/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 55 kW/75 HP
  • Output current 110/96 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter Integrated
i950-C75/400-3 i950-C75/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 75 kW/100 HP
  • Output current 150/124 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter Integrated
i950-C90/400-3 i950-C90/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 90 kW/125 HP
  • Output current 180/156 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter Integrated
i950-C110/400-3 i950-C110/400-3 Description
Lenze logo Order code / SKU
On request
  • Rated power 110 kW/150 HP
  • Output current 212/180 A
  • Output frequency 0-599 Hz
  • Rated mains voltage 3/PE 400/480 V AC
  • Motor output Single axis
  • Generation B
  • Product series i950 cabinet
  • EMC filter Integrated
Showing 1–25 of 563
  • Fault message ID
    0
    0x00000000 Description

    No error

    Cause

    No error

    Remedy

    For information only. No remedy necessary.

    Severity/response

    Information

  • Fault message ID
    537469777
    0x20092351 Description

    Motor utilization too high (i²xt)

    Cause

    Motor thermally overloaded, e.g. by an impermissible continuous current or by frequent or too long acceleration processes.

    Remedy

    Check drive sizing. Check the setting in the warning threshold or error threshold.

    Severity/response

    Fehler > CiA402 (configurable)

    Setting parameters: 0x2D50:001

  • Fault message ID
    537469824
    0x20092380 Description

    Trouble - utilization of the power section (ixt) too high

    Cause

    Power section overloaded.

    Remedy

    Check drive sizing.

    Severity/response

    Fault

  • Fault message ID
    537469825
    0x20092381 Description

    Warning - Utilization of the power section (ixt) too high

    Cause

    Power section overloaded.

    Remedy

    Check drive sizing.

    Severity/response

    Warning

  • Fault message ID
    537469828
    0x20092384 Description

    Ultimate motor current reached

    Cause

    Ultimate motor current reached.

    Remedy
    • Reduce the maximum current of the inverter. 0x6073
    • Optimize the current controller. 0x2942
    Severity/response

    Fault > CiA402 (configurable)

    Setting parameters: 0x2D46:002

  • Fault message ID
    537469829
    0x20092385 Description

    Parameterized max. motor current > max. device current

    Cause

    Parameterized max. motor current 0x6073 > max. device current 0x2DDF:002

    Remedy

    Reduce max. motor current. 0x6073

    Severity/response

    Warning

  • Fault message ID
    537469830
    0x20092386 Description

    Clamp is active

    Cause

    Max. device current has been reached. (Display in 0x2DDF:002)

    Remedy
    • Select a flatter speed ramp.
    • Reduce the load.
    • Set Imax controller more dynamically. 0x2B08
    Severity/response

    Warning

  • Fault message ID
    537469833
    0x20092389 Description

    Warning - device utilization (ixt) too high

    Cause

    Frequent and too long acceleration processes with overcurrent.

    Remedy

    Check drive sizing.

    Severity/response

    Warning

  • Fault message ID
    537469835
    0x2009238B Description

    Trouble - Device utilization (ixt) too high

    Cause

    Frequent and too long acceleration processes with overcurrent.

    Remedy

    Check drive sizing.

    Severity/response

    Fault

  • Fault message ID
    537473409
    0x20093181 Description

    Mains failure

    Cause

    The motor was decelerated to standstill via the mains failure control without an undervoltage fault occurring.

    Remedy
    • Check mains voltage.
    • Check mains settings.
    • Check fuses.
    Severity/response

    Fault

  • Fault message ID
    537477762
    0x20094282 Description

    Thermal overload of control unit

    Cause
    • Control card temperature > 100 °C
    • Ambient temperature too high
    Remedy
    • Provide for better cooling.
    • Reduce ambient temperature.
    Severity/response

    Information

  • Fault message ID
    537478016
    0x20094380 Description

    Fault - Motor temperature sensor

    Cause

    Motor PTC error.

    Remedy

    Connect PTC or switch off monitoring.

    Severity/response

    Warning (configurable)

    Setting parameters: 0x2D49:002

  • Fault message ID
    537478017
    0x20094381 Description

    Error - Motor temperature monitoring (PTC)

    Cause

    Motor PTC error.

    Remedy

    Connect PTC or switch off monitoring.

    Severity/response

    Fault > CiA402 (configurable)

    Setting parameters: 0x2D48:002

  • Fault message ID
    537478018
    0x20094382 Description

    Motor overtemperature (load encoder/master encoder)

    Cause

    Motor temperature via load encoder higher than variable temperature limit.

    Remedy

    Connect PTC or switch off monitoring. Set a higher warning threshold (0x2D49:003) and/or error threshold (0x2D49:004).

    Severity/response

    Warning (configurable)

    Setting parameters: 0x2D49:002

  • Fault message ID
    537478019
    0x20094383 Description

    Motor temperature sensor error (load encoder/master encoder)

    Cause

    Motor PTC error.

    Remedy

    Connect PTC or switch off monitoring.

    Severity/response

    Warning (configurable)

    Setting parameters: 0x2D49:002

  • Fault message ID
    537485328
    0x20096010 Description

    Internal error

    Cause

    Internal error

    Remedy

    Restart the device. If the error persists, contact the manufacturer.

    Severity/response

    Warning

  • Fault message ID
    537486096
    0x20096310 Description

    Incorrect parameter set download

    Cause

    CRC error in the parameter set detected. Vendor, product code or OBD revision are different. The parameter set is unknown.

    Remedy

    Recreate parameter set. Repeat parameter set download.

    Severity/response

    Warning

  • Fault message ID
    537486112
    0x20096320 Description

    Parameter error in object

    Cause

    Unknown index in the parameter set.

    Remedy

    Recreate parameter set.

    Severity/response

    Warning

  • Fault message ID
    537489584
    0x200970B0 Description

    Connected network option is not supported

    Cause

    The network option plugged into the inverter is not supported by the firmware.

    Remedy

    Update the firmware to a version that supports the network option. Use the network option supported by the current firmware version.

    Severity/response

    Fault

  • Fault message ID
    537490179
    0x20097303 Description

    Fault - Motor feedback

    Cause

    Defective encoder cable. Defective encoder.

    Remedy

    Check encoder cable. Check encoder. Switch off monitoring if no encoder is used.

    Severity/response

    Fault > CiA402 (configurable)

    Setting parameters: 0x2C45

  • Fault message ID
    537490180
    0x20097304 Description

    Error - Load encoder/master encoder

    Cause

    Defective encoder cable. Defective encoder.

    Remedy

    Check encoder cable. Check encoder. Switch off monitoring if no encoder is used.

    Severity/response

    Fault > CiA402 (configurable)

    Setting parameters: 0x2C55

  • Fault message ID
    537490304
    0x20097380 Description

    Motor encoder - Communication error

    Cause

    The communication to an encoder is disturbed.

    Remedy

    Check the supply voltage of the encoder. (0x2C42:002) Check encoder cable.

    Severity/response

    Fault > CiA402 (configurable)

    Setting parameters: 0x2C41:004

  • Fault message ID
    537490305
    0x20097381 Description

    Motor encoder - wrong absolute value because motor speed is too high

    Cause

    The absolute encoder position cannot be accepted as the motor rotates too fast.

    Remedy

    Let the motor coast.

    Severity/response

    Fault > CiA402 (configurable)

    Setting parameters: 0x2C41:004

  • Fault message ID
    537490306
    0x20097382 Description

    Load encoder/master encoder - Communication error

    Cause

    The communication to an encoder is disturbed.

    Remedy

    Check the supply voltage of the encoder. (0x2C42:002) Check encoder cable.

    Severity/response

    Fault > CiA402 (configurable)

    Setting parameters: 0x2C51:004

  • Fault message ID
    537490307
    0x20097383 Description

    Load encoder/master encoder - wrong absolute value because motor speed is too high

    Cause

    The absolute encoder position cannot be accepted as the motor rotates too fast.

    Remedy

    Let the motor coast.

    Severity/response

    Fault > CiA402 (configurable)

    Setting parameters: 0x2C51:004